GX-Series Control Panel Installation and Setup Guide
D-1
Appendix D: Event Log Messages
KEYPAD TEXT
DESCRIPTION
TRIGGER
EVENT
0001 + CU-BATT
Control Unit Standby Battery Low has occurred (battery voltage below
10.2VDC).
13. Elec Status
20. Fault
M
0001 - CU-BATT
Control Unit Standby Battery Low has finished (battery voltage now above
10.2VDC).
13. Elec. Status
M
0002 + CU-AC
Control Unit Mains (a.c.) Power Fail has occurred.
13. Elec. Status
20. Fault
M
0002 - CU-AC
Control Unit Mains (a.c.) Power Fail has finished.
13. Elec. Status
M
0003 + LID TAMP
Lid Tamper on control unit has occurred.
9. Tamper
M
0003 - LID TAMP
Lid Tamper on control unit has finished.
18. Zone restoral
M
0004 + AUX TAMP
Auxiliary Tamper on control unit has occurred.
9. Tamper
M
0004 - AUX TAMP
Auxiliary Tamper on control unit has finished.
9. Tamper
18. Zone restoral
M
+ABORT SET
Setting process aborted
11. Reset
NM
+AC+BATT
AC Fail and battery voltage low.
13. Elec. Status
20. Fault
M
+ AC FAIL
AC Fail zone activated (opened) or an AC Fail on a Power Supply Unit.
13. Elec. Status
20. Fault
M
– AC FAIL
AC Fail zone de-activated (closed) or an AC Fail on a Power Supply Unit has
stopped.
13. Elec. Status
20. Fault
M
+ALARM EXT
Alarm extend zone activated.
3. 24 Hours
16. Log Zone
M
ALM CAUSE
Reset of system required by entry of an alarm cause code.
Always TR
M
ADDED
Engineer has added a Module to the system.
9. Tamper
M
ARC TEST
Alarm Receiving Centre Test
Always TR
NM
+ATM-1
ATM-1 zone activated.
3. 24 Hours
16. Log Zone
NM
+ATM-2
ATM-2 zone activated.
3. 24 Hours
16. Log Zone
NM
+ATM-3
ATM-3 zone activated.
3. 24 Hours
16. Log Zone
NM
+ATM-4
ATM-4 zone activated.
3. 24 Hours
16. Log Zone
NM
AUTOTEST
Automatic Test of the system via a comms Module
Always TR
+AUTOTIMER Autoset
timer
activated.
None
NM
–AUTOTIMER Autoset
timer
de-activated.
None
NM
BURG HIGH
High priority intruder alarm zone open
2. Intrude
18. Zone Restoral
M
BURG LOW
Low priority intruder alarm zone open.
2. Intrude
18. Zone Restoral
M
+BAT FUSE
◊
Fault on battery protection
13. Elec Status
20. Fault
M
+ BATT LOW
Battery Low activated on Power Supply Unit.
13. Elec. Status
20. Fault
M
– BATT LOW
Battery Low de-activated on Power Supply Unit.
13. Elec. Status
20. Fault
M
+BEAM PAIR
Beam Pair zones activated (opened).
2. Intruder
NM
+BEGIN SET
Setting process started.
None
NM
+ BELL FAIL
Bell Fail zone opened.
16. Log Zone
NM
+ BELL TAMP
Bell Tamper zone activated (opened).
9. Tamper
M
– BELL TAMP
Bell Tamper zone de-activated (closed).
9. Tamper
18. Zone restoral
M
BOOT UP
System has been started up or restarted.
13. Elec. status
NM
CANCEL
Alarm activation Cancelled by a valid user Code (system or Group(s) still Set).
11. Reset/Cancel
NM
COMM FAIL
Communication Failure has occurred on a comms Module.
20. Fault
M
CONFIRM
Two independent alarms.
2. Intruder
M
COPY SITE
Remote Copy of the Site (system) has occurred via Remote Servicing or the
RS232 Module.
None NM
CUSTOM-
Custom-A zone activated (opened).
5. Custom zones
16. Log Zone
NM
CUSTOM-B
Custom-B zone activated (opened).
5. Custom Zones
16. Log Zone
NM
+CU-FUSE
◊
Control Unit protection trouble.
9. Tamper
13. Elec Status
20. Fault
M
DELAY ALM
PA Delay Alarm zone activated after PA Delay timeout.
1. PA/duress
M
◊
The PC board uses a PTC device instead of a fuse. The PTC serves as an automatically resetting fuse.
Summary of Contents for GX-48
Page 2: ......
Page 6: ...GX Series Control Panel Installation and Setup Guide iv ...
Page 26: ...GX Series Control Panel Installation and Setup Guide 2 18 ...
Page 32: ...GX Series Control Panel Installation and Setup Guide 3 6 ...
Page 40: ...GX Series Control Panel Installation and Setup Guide 4 8 ...
Page 46: ...GX Series Control Panel Installation and Setup Guide 5 6 ...
Page 184: ...GX Series Control Panel Installation and Setup Guide A 4 ...
Page 194: ...GX Series Control Panel Installation and Setup Guide C 2 ...
Page 200: ...GX Series Control Panel Installation and Setup Guide D 6 ...
Page 204: ...GX Series Control Panel Installation and Setup Guide F 2 ...
Page 207: ......