GX-Series Control Panel Installation and Setup Guide
D-5
KEYPAD TEXT
DESCRIPTION
TRIGGER
EVENT
TAG REJECT GRP
SET
Rejected card - group set
TAG REJECT ILL
TIME
Rejected card - illegal time
+TAMP C/V
constant Voltage tamper event
9. Tamper
M
+TAMP O/C
Zone changing to Tamper Open Circuit (greater than 12,000 Ohm).
9. Tamper
M
–TAMP O/C
Zone changing from Tamper Open Circuit to Normal Closed (1200 to 900 Ohm).
9. Tamper
18. Zone restoral
M
TAMP RST
Tamper Reset of the system has occurred.
9. Tamper
NM
+TAMP S/C
Zone changing to Tamper Short Circuit (less than 800 Ohm).
9. Tamper
M
–TAMP S/C
Zone changing from Tamper Short Circuit (less than 800 Ohm). to Normal
Closed (900 to 1200 Ohm).
9. Tamper
18. Zone restoral
M
+TAMPER
Tamper on a module activated (opened). A module is either a keypad, GX RIO,
Telecom Module or RS232 Module.
9. Tamper
M
–TAMPER
Tamper on a module de-activated (closed). A module is either a keypad, GX
RIO, Telecom Module or RS232 Module.
9. Tamper
18. Zone restoral
M
TEST O/P
Test Outputs menu (Menu Option 32) has been accessed.
None
NM
TIMEOUT
Timeout alarm after the Entry Time has expired.
10. Setting
M
+TIMER A
Timer A activated (on).
None
NM
–TIMER A
Timer A de-activated (off).
None
NM
+TIMER B
Timer B activated (on).
None
NM
–TIMER B
Timer B de-activated (off). None
NM
T/O-BURGL
Timeout alarm after the Entry Time has expired (same as TIMEOUT but used as
a SIA event).
2. Intruder
M
U/S EARLY
The Unset Early output has been activated before programmed time.
10. Setting
NM
UNSET
Unset of the system or Group(s).
10. Setting
M
URGENT
Urgent zone activated.
3. 24 Hours
M
VIBRATION
Vibration zone activated.
2. Intruder
16. Log Zone
NM
VIDEO
Video zone activated (opened).
2. Intruder
M
VID EXIT
Video Exit zone activated (opened).
2. Intruder
M
+WALK TEST
Walk Test has occurred.
14. Menu access
NM
–WALK TEST
Walk Test has finished.
14. Menu access
NM
WALL TAMP
Wall Tamper zone alarm.
9. Tamper
M
WRONG CD
Wrong Code alarm activation (6 consecutive wrong codes). This Requires a
system reset.
9. Tamper
M
24 HOURS
24 Hours zone activated (opened).
3. 24 Hours
M
NOTES: M = Mandatory.
NM = Non-Mandatory
A plus (+) means an event has started. A negative (-) means an event has finished.
Summary of Contents for GX-48
Page 2: ......
Page 6: ...GX Series Control Panel Installation and Setup Guide iv ...
Page 26: ...GX Series Control Panel Installation and Setup Guide 2 18 ...
Page 32: ...GX Series Control Panel Installation and Setup Guide 3 6 ...
Page 40: ...GX Series Control Panel Installation and Setup Guide 4 8 ...
Page 46: ...GX Series Control Panel Installation and Setup Guide 5 6 ...
Page 184: ...GX Series Control Panel Installation and Setup Guide A 4 ...
Page 194: ...GX Series Control Panel Installation and Setup Guide C 2 ...
Page 200: ...GX Series Control Panel Installation and Setup Guide D 6 ...
Page 204: ...GX Series Control Panel Installation and Setup Guide F 2 ...
Page 207: ......