GX-Series Control Panel Installation and Setup Guide
6-8
Omitted (Bypassed) Zones
If zones are omitted (bypassed) when the system starts setting, this is indicated on the keypad. The keypad
indicates how many zones are omitted.
Expiration Warning
During the last 25% of the programmed exit time outputs programmed as
Entry/Exit Horn
begin to pulse
rapidly, indicating that time is running short.
System Set (Armed) Indication
At the end of the exit time the
Entry/Exit Horns
become silent for four seconds. This allows the door to be
locked and secured and gives the detectors time to settle before the system finally sets. Two long tones are
emitted to confirm that the system has set. If all groups are set (armed) the keypad briefly displays the
message
SYSTEM IS SET
before returning to the normal banner.
Group Logic Setting (Arming) Restriction
If
Setting Logic
has been assigned to a group (refer to
63.1.2 = OPTIONS.Groups.Setting Logic
), the set
(armed) status of the groups must satisfy the conditions defined in the option to permit the group to set. If
the
Setting Logic
conditions are not satisfied, then the group cannot set. If multiple groups are being set
simultaneously, but one group is restricted due to the programmed
Setting Logic
, the remainder of the
groups set. The restricted group does not set; there is no warning or indication given.
If the programmed
Setting Logic
results in none of the selected groups being allowed to set, a warning
message is displayed on the keypad. This message does not appear if at least one group sets.
GX-069-V0
2 Groups not set
[<],[>] to view
Entry Time
The system begins the unsetting (disarming) routine whenever a
Final
or
Entry
zone activates. The
Entry/Exit horns
pulse slowly indicating that the entry time countdown has started. The user must go
directly to the keypad, using the agreed entry route, and unset (disarm) the system before the entry time
expires. When 75% of the entry time has elapsed the
Entry/Exit horns
pulse rapidly, indicating that time
is running short.
Timeout (Slow Entry)
If the entry time expires before a valid code is entered to unset (disarm) the group, a full alarm occurs. This
is recorded in the event log as a
Timeout
against the group which was in the process of being unset.
Straying from the Entry Route
If, during the entry routine, the user strays from the agreed entry route and activates a zone in a protected
area, a full alarm occurs.
Abort Time
Should the user exceed the entry time or stray from the entry route a full alarm occurs. However the
activation of the intruder output can be delayed to allow time for the user to abort the remote signaling. The
Abort Time
parameter can also be programmed so that an
Intruder
alarm is activated immediately when
the entry time expires or a zone is activated, but entry of any valid code cancels the alarm and deactivates
the
Intruder
outputs without the need for a system reset.
Abort Setting (Arming) Message
Zones that are open or opened during the exit period are indicated to the user by a rapid audible tone from
the entry/exit horns. The keypad displays the open zones and then prompts the user to abort the setting
(arming) by pressing the
esc
key. This message is designed to prevent users from re-entering the building,
closing the open zones, allowing the system to set (arm) and trapping the user in the building.
Summary of Contents for GX-48
Page 2: ......
Page 6: ...GX Series Control Panel Installation and Setup Guide iv ...
Page 26: ...GX Series Control Panel Installation and Setup Guide 2 18 ...
Page 32: ...GX Series Control Panel Installation and Setup Guide 3 6 ...
Page 40: ...GX Series Control Panel Installation and Setup Guide 4 8 ...
Page 46: ...GX Series Control Panel Installation and Setup Guide 5 6 ...
Page 184: ...GX Series Control Panel Installation and Setup Guide A 4 ...
Page 194: ...GX Series Control Panel Installation and Setup Guide C 2 ...
Page 200: ...GX Series Control Panel Installation and Setup Guide D 6 ...
Page 204: ...GX Series Control Panel Installation and Setup Guide F 2 ...
Page 207: ......