OPERA
TION
AND SER
VICE
When installation is complete, plug TrueSTEAM in and turn the humidity control on. Make sure it is running
properly before turning the system over to the homeowner. Once TrueSTEAM is running, day-to-day operation is
hands-free, except for occasional cleaning. The homeowner can use the control to adjust the humidity setpoint,
adjust the frost setting (if used), or turn TrueSTEAM off as desired.
Slide the cover into place and secure with the
cover screw.
Turn on the water supply at all valves. Cold water will
flow to the TrueSTEAM but will not fill the tank until the
unit is turned on and a call for humidity is made.
Plug in the TrueSTEAM power cord.
•
The Power light will turn on, indicating that
TrueSTEAM has power.
Turn the humidity control to On.
•
The Humidifying light will start blinking. This means
TrueSTEAM is in Stand-by.
Press/release the Go button to prepare TrueSTEAM
for use. TrueSTEAM will automatically reset if the Go
button is not pressed after 5 minutes.
•
The tank will fill with cold water and the humidifier
light will be blinking. Water flow stops automatically
when the tank is full.
•
The Humidifying light will be solidly on — it will stop
blinking — when TrueSTEAM is heating water for
steam production.
Wait until TrueSTEAM produces steam, then check
the following:
•
Make sure air is blowing from furnace. Typically, the
blower turns on 10 –15 minutes after the call for
humidity if TrueSTEAM is controlling the fan.
•
Check all water line connections to ensure there
are no leaks before leaving the job site.
•
Turn the setpoint to the desired level when testing
is complete. If humidity is not needed, set the
control to Off.
M32916
COLD and
SOFTENED water
should enter the
TrueSTEAM
Hot Water
Heater
Water
Softener
Startup and Checkout
TrueSTEAM Humidification System 69-2285—01
45
3
2
1
4
5