OPERA
TION
AND SER
VICE
STEP FIVE:
Reinstall the Tank
Before reinstalling the tank and cover, perform
these checks:
•
Clear any dust from the ventilation holes
in the cover.
•
Clear any debris from the water drain tube.
•
Make sure the water tank gasket seal is seated
properly in the TrueSTEAM base. Make sure the
gasket is in good condition (no cracks or tears)
before attaching the tank.
Attach tank by securing the latch and plug
in TrueSTEAM.
If the control is calling for humidity, the Humidifying
light will blink at startup. TrueSTEAM waits 5 minutes
to complete the tank reconnection before acting on this
call.
Engage the white water valve to the tank’s black
spool, then turn the manual shutoff valve to the “Lock”
position and plug in the power cord.
Check that TrueSTEAM is still mounted level and is
securely in place on the mounting bracket.
Press the Go button once the tank is completely
reconnected. This will ready TrueSTEAM to act on the
control’s call for humidity (if present).
M29633
M29628
TrueSTEAM Humidification System 69-2285—01
52
2
4
3
1