6
7
DRAINAGE INSTRUCTIONS
There are two options to collect the extracted water
1. In the water tank (6)
2. Via the water hose (7) which should be attached to the water out
hole (5)
WATER TANK
(See page 5)
When not using the water hose, the water will drain into the tank
at the rear of the unit. As soon as the tank is full the light (13) will
illuminate and the unit will shut off automatically. The tank should
be emptied as shown in the diagram (See Fig. 1 & Fig. 2).
CONTINUOUS DRAINAGE
(See page 5)
To use the continuous drainage function attach the water hose (7)
to the water out hole (5) as shown in diagram (See Fig. 3). Replace
the water tank and use the unit as indicated under operating
instructions.
FILTER CLEANING
(See page 5)
The filter can be removed from its slot by removing the water tank
and sliding the filter downwards as shown in diagram (See Fig. 4).
Every 2 weeks, remove the filter and clean it with warm water, below
40°C. Allow it to dry fully and then replace.
CLEANING, MAINTENANCE AND STORAGE
We recommend you clean the dehumidifier regularly. Before you
start cleaning, press the power key to the OFF (12) position and pull
the plug out of the power socket.
DISINFECTION
Every two weeks you should also disinfect the water tank (6). For
this, use a domestic disinfectant. Wipe all the outer surfaces with a
soft, dry cloth.
MAINTENANCE AND STORAGE
If you do not wish to use the dehumidifier for a longer period (a week
or more), clean the dehumidifier and dry it and store in an upright
position in a cool, dry location.
DISPOSAL
This symbol on the product or its packaging indicates that
the appliance cannot be treated as normal domestic trash,
but must be handed in at a collection point for recycling
electric and electronic appliances.
Your contribution to the correct disposal of this product protects
the environment and the health of your fellow men. Health and the
environment are endangered by incorrect disposal.
Further information about the recycling of this product can be
obtained from your local town hall, your refuse collection service, or
in the store at which you bought the product.
This regulation is valid only in EU member states.
CONDITION OF PURCHASE
As condition of purchase the purchaser assumes responsibility for
the correct use and care of this KAZ product according to these user
instructions. The purchaser or user must himself or herself decide
when and for how long this KAZ product is in use.
WARNING: IF PROBLEMS ARISE WITH THIS KAZ PRODUCT,
PLEASE OBSERVE THE INSTRUCTIONS IN THE WARANTEE
CONDITIONS. DO NOT ATTEMPT TO OPEN OR REPAIR THE KAZ
PRODUCT YOURSELF, AS THIS COULD LEAD TO TERMINATION
OF THE WARANTEE AND CAUSE DAMAGE TO PERSONS AND
PROPERTY.
Technical modifications reserved.
HD016E
220–240 V ~ 50Hz
410W
ENGLISH
ENGLISH
IMPORTANT SAFETY ADVICE
1. Please read the operating instructions carefully before using your
dehumidifier for the first time and keep them in a safe place.
2. Never immerse the appliance in water or other liquids.
3. Never operate the appliance if a cable or connector has been
damaged, after appliance malfunction or if the appliance was
dropped or otherwise damaged.
4. Disconnect the appliance from main power whenever it is not in
use, before relocating it, and before cleaning.
5. Operate the appliance only at the voltage specified on the type
plate.
6. Do not place heavy objects on the appliance.
7. To prevent spillage, empty the water tank before relocating the
appliance.
8. This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.
13. If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
14. The device should be positioned at least 50cm from the wall or
other objects.
15. When the dehumidifier is in operation, the compressor will
produce heat.
COMPONENTS
(See page 4)
1. Control
panel
2. Air outlet grille
3. Handle
4. Air intake grille
5. Water out hole
6. Water tank
7. Water hose
8. Power cord
CONTROL PANEL
(See page 4)
9. Humidity
display
10. Timer (24 hr)
11. Timer on light
12. Power button (on/off)
13. Tank full light
14. Pilot light
15. Speed setting
16. High speed
17. Low speed
18. Humidity setting (50%, 60%, 70%, 80%, AU, CO)
19. Defrost function
OPERATING INSTRUCTIONS
1. Press the power button (12) to turn the unit on.
2. Press the speed button (15) to choose between the high or low
setting.
3. If you want to allow the unit to run for a certain amount of time
press the timer button (10) repeatedly to select the desired
number of hours.
TIMER SETTING
1. The unit will switch off automatically once the selected amount
of time has elapsed.
2. Pressing the power button before the selected time has
elapsed will cancel the timer option and the unit will turn off
immediately.
HUMIDITY SETTING
1. The dehumidifier will not function if the desired humidity
setting is higher than the ambient humidity.
2. The operational temperature range for this unit is between 5-35 °C.
3. Choose the humidity % by pressing the keys until the desired %
shows in the display.
4. The unit will shut off automatically as soon as the desired
humidity is reached. Once the humidity reaches 3% above the
desired % the unit will automatically turn back on again.
5. The Auto (AU) mode can be selected so that the unit works in a
default mode as follows.
a. The compressor turns off when the ambient temperature is
below 5°C.
b. The humidity is automatically set to 60% if the ambient
temperature is between 5°C and 20°C.
c. The humidity is automatically set to 55% if the ambient
temperature is between 20°C and 27°C.
d. The humidity is automatically set to 50% if the ambient
temperature is above 27°C.
6. The Continuous (CO) mode can be selected so that the unit works
continuously independent of the ambient humidity.
TANK FULL
As soon as the tank capacity is reached the light (13) will illuminate.
The compressor will shut off automatically. The tank should be
emptied and replaced and then the unit will restart automatically
after a period of three minutes.