APPENDICES
Humidifier 69-2413EF—09
26
Humidifying Capacity
At 120°F (49°C) plenum temperature and 0.20 static pressure
drop across supply and return:
HE100/150: up to 12 gallons per day (gpd)
(46 liters per day [lpd])
HE200/250: up to 17 gpd (65 lpd)
HE300: up to 18 gpd (68 lpd)
Humidified Area
HE100/150: Up to 16,000 cubic feet
HE200/250: Up to 20,000 cubic feet
HE300: Up to 24,000 cubic feet
Dimensions
HE100/150: 14.5 in. W x 14 in. H x 10.1 in. D
(368 mm W x 356 mm H x 257 mm D)
HE200/250: 15 in. W x 17.15 in. H x 10.1 in. D
(381 mm W x 436 mm H x 257 mm D)
HE300:
15.5 in. W x 16.8 in. H x 10.3 in. D
(394 mm W x 427 mm H x 262 mm D)
Humidifier Pad Dimensions
HE100/150: 9-1/2 in. W x 9-13/16 in. H x 1-1/2 in. D
(241 mm W x 249 mm H x 38 mm D)
HE200/250: 10 in. W x 13 in. H x 1-1/2 in. D
(254 mm W x 330 mm H x 38 mm D)
HE300: 10 in. W x 13 in. H x 1-1/2 in. D
(254 mm W x 330 mm H x 38 mm D)
Static Pressure
HE100/150/: Supply plenum static pressure no greater
200/250
than .3 in. w.c.
HE300:
Supply plenum static pressure no greater
than .4 in. w.c.
Plenum Opening Dimensions
HE100/150: 9-5/16 in. W x 9-7/16 in. H (238 mm W x 241 mm H)
HE200/250: 9-3/4 in. W x 12-5/8 in. H (248 mm W x 321 mm D)
HE300: 13-1/2 in. W x 14-1/16 in. H (343 mm W x 357 mm D)
Bypass Duct Opening Dimensions (HE100/150/200/250)
6 in. (152 mm)
Operating Ranges
34ºF–90ºF (1.1ºC–32ºC)
Humidity: 0–95% RH, non-condensing
Drain Fitting
1/2 in. (13 mm) I.D. plastic hose connected directly to drain
fitting on unit.
Electrical Ratings and Tolerances
HE100/200: 24VAC, 60 Hz, 0.5 A maximum
HE150/250: 24VAC, 60 Hz, 0.75 A maximum
HE300: 120VAC, 60 Hz, 1 A maximum
A: Specifications