NVR Configurations | 91
800-18160 - B - 07/2014
Figure 3-47
Alarms Configuration Interface
Table 3-22
Alarm Configurations
Parameter
Description
Event Type
Select from four types:
Local input alarm
: The alarm signal system detects from the
alarm input port.
Network input alarm
: An alarm signal from the network.
IPC external alarm
: The on/off alarm signal from the camera,
which activates the local NVR to receive the IP camera’s alarm
if there is an alarm occurring at the camera.
IPC offline alarm
: When enabled, the system generates an
alarm when the front end IP camera disconnects from the
local NVR. The alarm can activate recording or taking a
snapshot, for example. The alarm can last until the camera
and the NVR connection resumes.
Alarm In
Select a channel.
Enable
Click to enable the this alarm configuration.
Device Type
Select either
Normally Open
or
Normal Closed
.