11
Electrical Characteristics
HF800 D-sub 25pin male connector
Power, COM and I/O Connector Pinout
Pin number
Name
Function
9,13
Vin
Power supply input(10VDC-30VDC)
7,25
GND
Power supply ground
1
Shield
Chassis shield
2
3
4
5
RS232_TX
RS232_RX
RS232_RTS
RS232_CTS
TXD(output)
RXD(input)
RTS(output)
CTS(input)
6
10
18
19
IN2A
IN2B
IN1A
IN1B
External Input channel 2 A
External Input channel 2 B
External Input channel 1 A
External Input channel 1 B
8
22
11
12
O1+
O1-
O2+
O2-
Output 1 +
Output 1 -
Output 2 +
Output 2 -
14
15
16
17
RS485_Z
RS485_Y
RS485_A
RS485_B
RX-(RS422 RX- only) (input)
RX+(RS422 RX+ only) (input)
T/R+(RS485 data+ and RS422 TX+)
T/R-(RS485 data- and RS422 TX-)
20,21,23,24
Reserved
Reserved
Output
Two digital outputs (Output1, Output2) are available, with the protection of 2
optocouplers. The maximum V
CE
of the optocoupler is 30VDC, maximum continuous
current is 50mA. User should adjust the VDD and the load resistance to make sure
the current
is less than 50mA, and VDD is less than 30VDC. There are two Zener
diodes paralleled with the Output Pin, and the Breakdown Voltage of the diode is
5.6V, therefore, if the external power supply which directly connected to the output
pin is higher than 6V, the voltage will be clamped to 5.6V. User could use these 2
outputs to control beeper, external illumination LEDs.
Typical use case:
Summary of Contents for HF800 Series
Page 1: ......
Page 15: ...15 3 Mounting bracket overall dimensions ...
Page 21: ...21 Privacy statement Privacy statement ...
Page 22: ...22 Choose destination location Ready to install program ...
Page 23: ...23 Setup status Complete ...
Page 39: ...39 3 Right click on Local Area Connection and click on Properties ...