12
Input
Two digital inputs (Input1, Input2) are available, with the protection of 2
polarity insensitive optocouplers. Typical forward voltage of the optocoupler is1.35V,
maximum current is 50mA. User should adjust the VDD and the serial resistor to
make sure the current
is less than 50mA, VDD should be more than 1.35VDC and
less than 30VDC. Maximum input frequency is 100KHz. User could connect external
IR trigger, PLC to these 2 inputs.
Typical use case:
Typical NPN type IR connection to input2 layout as below, input1 as well, just need to
repalce IN2A with IN1A, replace IN2B with IN1B. A series resistor(1Kohm to
1.5Kohm) is recommended to be put between V+ and IN2A to limit the current.