58
Redundant times:
output the decode result only when got identical barcodes
information for specific times.
Check Digit Transmit:
This selection allows you to specify whether the check digit
should be transmitted at the end of the scanned data or not.
2/5 Digit Addenda:
This selection adds 2 or 5 digits to the end of all scanned EAN-
13 data.
Addenda Required:
When Required is set, the HF800 only reads EAN-13 bar codes
that have addenda.
Addenda Separator:
When this feature is On, there is a space between the data
from the bar code and the data from the addenda. When turned Off, there is no
space.
ISBN On:
When On is set, EAN-13 Bookland symbols are translated into their
equivalent ISBN number format.
MSI
Click the “MSI” in the left list then all its related parameters will be shown on the right.
Minimum Length:
output the decode result when the symbology length equal or
larger than the minimum length.
Maximum Length:
output the decode result when the symbology length equal or
shorter than the maximum length.
Check Character:
Different types of check characters are used with MSI bar codes.
You can program the HF800 to read MSI bar codes with Type 10 check characters.
When Check Character is set to
Validate Type 10/11 and Transmit
, the HF800 only
reads MSI bar codes printed with the specified type check character(s), and transmits
the character(s) at the end of the scanned data. When Check Character is set to
Validate Type 10/11, but Don’t Transmit
, the unit only reads MSI bar codes printed
with the specified type check character(s), but does not transmit the check
character(s) with the scanned data.
GS1 DataBar Omnidirectional
Click the “GS1 DataBar Omnidirectional” in the left list then all its related parameters
will be shown on the right.
Summary of Contents for HF800 Series
Page 1: ......
Page 15: ...15 3 Mounting bracket overall dimensions ...
Page 21: ...21 Privacy statement Privacy statement ...
Page 22: ...22 Choose destination location Ready to install program ...
Page 23: ...23 Setup status Complete ...
Page 39: ...39 3 Right click on Local Area Connection and click on Properties ...