8
The input voltage of the adaptor is 100 - 240VAC, frequency is 50Hz - 60Hz,
output voltage is 12.00+/-0.6VDC, maximum current is 1.25A. The adaptor should
co-work with the plug, recommend to buy them both from Honeywell as an assembly.
Note: The inside of the DC plug is negative, outside is positive. Recommend to use
Honeywell adaptor only.
Terminal pinout for external I/O + RS232 cable:
Recommend to connect Shield to Ground for better EMI performance.
The Female DB9 connector description:
Pin NO.
Description
1
Shield
2
RS232_TX(output)
3
RS232_RX(input)
5
Ground
7
CTS(input)
8
RTS(output)
6,7,13,14 Reserved
The 14 Pin connector description:
Pin NO.
Description
Pin NO.
Description
1 Vin
Power supply
8 GND
Power supply ground
2 IN1B
External input 1B (Polarity insensitive)
9 O1+
Positive Output 1
3 IN1A
External input 1A (Polarity insensitive)
10 O1-
Negative Output 1
4 IN2B
External input 2B (Polarity insensitive)
11 O2+
Positive Output 2
5 IN2A
External input 2A (Polarity insensitive)
12 O2-
Negative Output 2
6,7,13,14 Reserved
Terminal pinout for external I/O + RS485/422 cable:
There are 2 switches on the 485/422 cable, if slide on, HF800 485/422 will
terminated with 120ohm, if slide off, there will be no termination resistor.
Note: For better signal quality, user should confirm that there are 2 120ohm
termination resistors on data line (between data+ and data-), one near to host, the
other one on the end.
Summary of Contents for HF800 Series
Page 1: ......
Page 15: ...15 3 Mounting bracket overall dimensions ...
Page 21: ...21 Privacy statement Privacy statement ...
Page 22: ...22 Choose destination location Ready to install program ...
Page 23: ...23 Setup status Complete ...
Page 39: ...39 3 Right click on Local Area Connection and click on Properties ...