6
INSTALLATION (CONTINUED)
IMPORTANT:
Do not replace or lengthen the hose as this could cause the unit to malfunction.
The length of the hose is scientifically determined by the specifications and airflow of the air
conditioner. Extending the hose beyond the specified dimensions can cause heat to collect or flow
back into the air conditioner causing the unit to malfunction.
The supplied hose has a diameter of
5.9" (15 cm) and can be extended from
10.23'' to 47'' (26cm to 120cm).
Do not bend (to the extent shown above) the hose. A bent hose will block exhaust air
and cause the unit to malfunction or shut-off.
Make sure the back of the unit is at least 20" (50 cm) away from the wall. Do not place the unit in
front of curtains or drapes as this could obstruct the airflow.
•
•
•
WARNING:
Any warranties included with this product will be voided if an extra extension hose is
added to the originally provided installation kit or if the installation is performed differently than the
manufacturer's instructions, without proper consultation. Please contact Customer Support for help
with installation procedures if needed.
Not Recommended
Recommended
EN
20" (50 cm)
MIN 35.6 cm
MA
X. 14" (36 cm)
MA
X. 40" (102 cm)
4. The Local Air Conditioner is now ready to use.
Extend the exhaust hose through an open window and close the window as far as possible
trapping the Exhaust Nozzle (as shown below).
Push-Out Windows
3b
.