166
HH1800 User Guide
Examples of Query Commands
In the following examples, a bracketed notation [ ] depicts a non-displayable response.
Example:
What is the range of possible values for Codabar Coding Enable?
Enter:
Response:
cbrena*.
CBRENA0-1[ACK]
This response indicates that Codabar Coding Enable (CBRENA) has a range of values from 0 to
1 (off and on).
Example:
What is the default value for Codabar Coding Enable?
Enter:
Response:
cbrena^.
CBRENA1[ACK]
This response indicates that the default setting for Codabar Coding Enable (CBRENA) is 1, or
on.
Example:
What is the device’s current setting
for Codabar Coding Enable?
Enter:
Response:
cbrena?.
CBRENA1[ACK]
This response
indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on.
Example:
What are the device’s settings for all Codabar selections?
Enter:
Response:
cbr?.
CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.