114
HH490 User Guide
Require 5 Digit Addenda
EAN-13 Beginning with 979 Addenda Required
These settings program the scanner to require a 5 digit addenda only on EAN-13
barcodes that begin with “979.” The following settings can be programmed:
Require 5 Digit Addenda: All EAN-13 barcodes that begin with “979” must have
a 5 digit addendum. The EAN-13 barcode with the 5 digit addendum is then
transmitted as a single, concatenated barcode. If a 5 digit addendum is not found
within the
period, the EAN-13 barcode is discarded.
Don’t Require 5 Digit Addenda: If you have selected Require 5 Digit Addenda,
and you want to disable this feature, scan Don’t Require 5 Digit Addenda.
EAN-13 barcodes are transmitted, depending on the setting you are using for
Default = Don’t Require 5 Digit Addenda.
* Don’t Require 5 Digit Addenda
Require 5 Digit Addenda
Addenda
Timeout
You can set a time during which the scanner looks for an addenda. If an addenda
is not found within this time period, the data can be either transmitted or
discarded, based on the setting you are using for
. Set the length (in milliseconds) for this timeout by scanning the
barcode below, then setting the timeout (from 0-120 milliseconds) by scanning
digits from the
beginning on page 211 of this manual, then
Save.
Default = 120.
Note:
The Addenda Timeout setting is applied to all addenda and coupon code searches.
Addenda Timeout