52
Before You Begin Configuring
Preset Tours
In a preset tour, the PTZ dome moves from one preset to another. The PTZ dome remains
at each position for a specified amount of time (dwell time) before moving to the next preset
position. You can configure up to 16 preset tours. Each preset tour can consist of up to 64
presets. For details on configuring a preset tour, see
Configuring a Preset Tour
on page
65
.
The time interval for which the PTZ dome stays at a preset is referred to as the dwell time.
The dwell time can range from 1 to 99 seconds. The speed at which the PTZ camera moves
from one preset to another preset is referred to as the velocity. The velocity can range from
1
o
to 480
o
per second, depending on the capability of the camera model.
Note
You can start a preset tour after configuring it. To start a preset tour, select the
preset tour under Preset Tour Details and then click
.
Starting a Preset Tour
1.
Click the
Live View
tab.
2.
Click
Run
in the PTZ Settings pane. The
Run Cont. Preset Tour
options appear.
3.
Type in the tour number in the field next to
Run Cont. Preset Tour
. If the tour
number is less than 10, type
0
before the number. For example, for preset tour 9, type
09
.
4.
Click
Enter
. The preset tour starts and the PTZ camera moves to the first preset in the
tour. The tour loops until you break the cycle.
Stopping A Preset Tour
You can stop a preset tour by:
•
Using the PTZ Control
•
Selecting another function (for example, start a Mimic Tour)
•
Clicking
Halt
Summary of Contents for HNVE1
Page 1: ...Document 800 04195 Rev B 11 09 Reference Guide EQUIP Series HNVE1 V2 1 1 Channel Encoder ...
Page 2: ......
Page 3: ...Reference Guide ...
Page 10: ...10 Tables ...
Page 14: ...14 ...
Page 26: ...26 Encoder Installation ...
Page 58: ...58 Before You Begin Configuring ...
Page 84: ...84 Reference Information ...
Page 86: ...86 Glossary ...
Page 90: ...90 ...
Page 91: ......