54
Before You Begin Configuring
IP and Firmware Settings
The IP and Firmware Settings panel on the Device settings tab mirrors the information that
is available in the Honeywell IP Utility. It provides read-only network and firmware settings
and video formats without having to access the IP Utility.
Figure 4-7
IP and Firmware Settings on the Device Information Tab
Alarm Settings
Figure 4-8
shows the alarm settings on the Device Settings tab. See
Programming Alarm
Contacts
, page
59
for more detailed information.
Figure 4-8
Alarm Settings on the Device Settings Tab
Device Name
as entered in the IP
Utility program
IP Address
on the network
(DHCP/Static/APIPA)
Subnet Mask
and
Default
Gateway
that connects the HNVE1
to the network
MAC Address
is a factory assigned
address unique for each device
Firmware Settings
including
product name and version
Video Format
(NTSC or PAL)
Set the
Alarm Input
as Normally
Open, Normally Close, or Disable
Set the
Alarm Output
as Normally
Open or Normally Close