HPSR101

33-00349EF—06

2

MOUNTING 

Hang Hole Flow

1.

Hang the panel on a wall-mounted screw. 

Fig. 1. 

2.

Level the panel.  

Fig. 2. 

3.

Put the 2 bottom screws in. 

Fig. 3. 

WIRING AND SETUP

Power Input

Resideo Hydronic Panels include a convenient wiring 
terminal for wiring 120V/60Hz/1Ph power. These 
terminals, found at the bottom left side of the panel, 
provide power to the transformer and all pumps installed 
on the system.

Transformer

This panel provides one 24V, 15VA transformer to power 
the thermostat. The transformer can be replaced in the 
event of failure by removing the mounting screws and 
wiring in a new transformer in its place.

Status Indicators

Resideo Hydronic Panels feature Advanced Status 
Lighting. This includes a transformer status light on the 
status panel, and an Input Power Status Light near the 
bottom left corner of the Zone Panel. These indicators 
show the Power Status of the Panel at all times.

Zone Pump

Resideo Hydronic Panels are compatible with common 
zone pumps and can be wired in as shown in the 
schematic on page 3.

Thermostat Compatibility

Resideo Hydronic Panels are compatible with most 
thermostats available on the market. This including both 
power stealing and electromechanical type thermostats. 
For convenience, three terminals have been made 
available.

Additionally Resideo Hydronic Panels are compatible with 
Resideo Equipment Interface Modules in installations 
were sufficient wiring is not available.  

Fig. 4. 

NOTE:

For power stealing thermostats, wire to R and W 
on the zone panel. There are no additional com-
ponents required to make these thermostats 
function. For all thermostats that require a C wire 
for power there is a C terminal available on the 
panel for each thermostat.

WARNING

Wiring connections must be made in accordance 
with all applicable electrical codes. Use copper 
wire only. 120 VAC wiring must have a minimum 
temperature rating of 75C. Failure to follow this 
instruction can result in personal injury or death 
and/or property damage. 12-18 gauge wire 
recommended for 120 VAC connections, 14-
22 gauge wire for thermostat connections, and 
14-22 gauge wire for 24V source connections. 

M37297

M37298

M37299

 

R: 24v Hot (Commonly Red)

 

W: Heat (Commonly White)

 

C: Common 24v (Commonly Blue)

R W C

M37090

Summary of Contents for HPSR101

Page 1: ...NEC Class 1 wire for all line voltage wiring connections Class 1 wires must be rated for at least 167 F 75 C 4 For installation by professionals only PANEL SPECIFICATIONS Table 1 NOTES 1 All circulator relay connections are rated for 5A full load and 30A locked rotor 1 6 to 1 2HP depending on technology at 120VAC Check circulator plate ratings to ensure full load current is not exceeded 2 All ther...

Page 2: ...e schematic on page 3 Thermostat Compatibility Resideo Hydronic Panels are compatible with most thermostats available on the market This including both power stealing and electromechanical type thermostats For convenience three terminals have been made available Additionally Resideo Hydronic Panels are compatible with Resideo Equipment Interface Modules in installations were sufficient wiring is n...

Page 3: ...AC POWER TO TRANSFORMER 120VAC N H NC NO COM 24VAC 15VA 6 AMP FUSES CIRCULATOR TO BOILER RELAY THERMOSTAT WIRING NON CONNECTED OR POWER STEALING ALL TRANSFORMER CONNECTIONS ARE FACTORY WIRED M37270 NC NO COM R W C T STAT CALL POWER N H 1 AMP FUSE LINE VOLT STATUS POWER IN 24 VAC POWER TO TRANSFORMER 120VAC 24VAC 15VA 6 AMP FUSES ALL TRANSFORMER CONNECTIONS ARE FACTORY WIRED M37271 THERMOSTAT WIRIN...

Page 4: ...wing two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 5 YEAR LIMITED WARRANTY Resideo warrants this product to be free from defects in the workmanship or materials under normal use and service for a period of five 5 years from the date of purchase by the consumer If at a...

Page 5: ...s de câblage de tension secteur Les câbles de classe 1 doivent être adaptés à une température d au moins 75 C 167 F 4 Pour installation par des professionnels seulement SPÉCIFICATIONS DU PANNEAU Tableau 1 REMARQUE 1 Tous les raccordements du relais du circulateur sont adaptés à un rotor bloqué de 30 A et à une charge nominale de 5 A 1 6 à 1 2 HP en fonction de la technologie à 120 V c a Vérifiez l...

Page 6: ...ues Resideo sont compatibles avec la plupart des thermostats disponible sur le marché tels que les thermostats qui n ont pas besoin du fil commun fil C et les thermostats électromécaniques Pour des raisons pratiques trois bornes sont disponibles En outre les panneaux hydroniques Resideo sont compatibles avec les modules d interface de l équipement Resideo dans les installations ne disposant pas de...

Page 7: ...RANSFORMATEUR N H 24 V c a 15 VA FUSIBLES DE 6 A CIRCULATEUR VERS LE RELAIS DE LA CHAUDIÈRE CÂBLAGE DU THERMOSTAT SANS LE FIL C TOUS LES RACCORDEMENTS DU TRANSFORMATEUR SONT RÉALISÉS EN USINE MF37270 NC NO COM NC NO COM R W C DEMANDE DU THERMOSTAT ALIMENTATION N H FUSIBLE DE 1 A ÉTAT DE LA TENSION SECTEUR ALIMENTATION DE 24 V c a ALIMENTATION AU LE TRANSFORMATEUR DE 120 V c a 24 V c a 15 VA FUSIBL...

Page 8: ... interférences dangereuses et 2 ce dispositif ne doit accepter aucune interférence reçue notamment les interférences à l origine d un fonctionnement indésirable GARANTIE LIMITÉE DE 5 ANS Resideo garantit ce produit contre tout vice de fabrication ou de matériau dans la mesure où il en est fait une utilisation et un entretien convenables et ce pour cinq 5 ans à partir de la date d achat par le cons...

Reviews: