background image

1. 

Check

 

the

 water purifier and pipe fittings regularly to see 

whether

 

the

re is any leakage, 

and avoid property damage caused by leakage.

2. 

When

 you go out or do not use 

the

 water purifier for a long time, please 

shut

 off 

the 

water inlet (turn off 

the

 water inlet ball valve), disconnect 

the

 power, open 

the 

water

faucet to drain of

f the water in the storage tank, and close the water faucet.

3. If 

the

 purifier 

has

 not been used for more 

than

 5 days (more 

than

 3 days in summer), 

please drain off 

the

 water in 

the

 storage tank and 

flush

 

the

 purifier for about 10 

minutes; 

Do not keep the filter unused for long after the water flows through 

especially in summer, 

generally no mor

e than 14 days.  

4.  Do  not  place 

heavy

  objects  and  corrosive  materials  on 

the

  water  purifier  to  avoid 

possible  damages  to 

the

  water 

purifier;

 

the

  consequential  water  leakage  and  electric 

leakage may cause severe personal injury and property loss.

5. Cut off 

the

 water and power 

when

 

the

 water purifier will not be used for a long time. 

When reusing the water purifier, flush it according to the steps as using it for the first 

time. If 

the

 water quality is unsatisfactory after 

flushing,

 replace 

the

 filter cartridges as 

soon as possible.

6. Cut off 

the

 power and water before replacing 

the

 filter cartridge. Pay attention to 

the 

direction and order of 

the

 filter cartridges. 

After

 replacing 

the

 filter cartridges, carry out 

commissioning and flushing just like using it for the first time.

 If the pipe or 

related par

ts of the water filter a

re leaking.

 If the 

r

elated components of the water purifier malfunction.

 If any other anomalies or failu

res occur.

Instructions for Commissioning

and Operation

10

7. In case of 

the

 following situations, cut off 

the

 power and 

the

 water input of 

the 

purifier  

(turn off 

the

 water inlet ball valve) immediately, and contact 

the

 service provider as soon 

as possible:

 

Summary of Contents for HRO-50

Page 1: ...HRO 50 Water Purifier Product Installation Operation Manual Honeywell Environmental Combustion Controls Tianjin Co Ltd ...

Page 2: ...Important Notes P2 Installation Instructions Instructions for Commissioning and Operation Care Maintenance Warranty Provisions Packing List P6 P9 P10 P11 P12 P13 Product Functions P3 P5 1 Content ...

Page 3: ...Do not disassemble the water purifier without approval or hand over the water purifier to unauthorized service personnel for repair Improper repairs may cause danger Any malfunction caused by improper use is not covered in the warranty This water purifier is only designed for household use and may not necessarily apply to other purposes For the water purifier maintenance and filter cartridge repla...

Page 4: ...erent users and effectively increases the TDS value of water production The water purifier filter cartridges need to be changed regularly Replacement cycle will be indicated at the faucet separate package base The green light indicates it is within the safe range the yellow light indicates it needs to be replaced close to safe range and the red light indicates it exceeds the safety range and must ...

Page 5: ...MPa 0 35MPa 5 38 C 0 26 L Min 3 tons Input 220V AC Outlet 24V DC Municipal tap water conforming to local standard Table 1 4 Filter adapter Front PP cotton filter cartridge Front activated carbon filter cartridge Rear PP cotton filter cartridge Reverse osmosis membrane filter cartridge Rear activated carbon filter cartridge sterilization Transformer To faucet To storage tank Storage tank 1 2 tee jo...

Page 6: ...ge the water inside the water purifier The freezing of water pipes or water purifier can cause the failure of the shell or water supply pipeline damaged and possible injury Do not touch the power cord plug with wet hands which may cause electric shock Effectively remove suspended solids sediment rust and other impurities Effectively remove residual chlorine humus disinfection byproducts odor color...

Page 7: ...0VAC power for the water purifier The receptacle withstand current must be greater than 5 0A or else it may cause overheat or fire accident Disconnect the power before the installation Do not touch the power plug with wet hands or else it may cause electric shock Disconnect the power before installation Before installation please turn off the water inlet valve Confirm the location where the water ...

Page 8: ...e Gasket Threaded nipple Figure 6 Figure 7 Figure 8 Figure 9 Cold water pipe connection nut Gasket Three way Gasket Cold water valve Ball valve Nut 1 4 PE pipe PTFE tape Nut Ring Plug filter cartridge at the fourth stage of the filter adapter and rear activated carbon filter cartridge at the fifth stage of the filter adapter Align the 2 connection pipe of the filter cartridge to the connection hol...

Page 9: ...h stage Figure 11 and finally put the other end into the sewer or recycling container 8 Figure 10 Figure 11 To the sewer or recycling container Step 5 Open the cover and rotate the control valve according to the water purification require ments Align it with R to produce reverse osmosis water and rotate clockwise to M to produce mixed water Figure 12 Step 6 Connect the PE pipe connected in Step 4 ...

Page 10: ...etely 4 Confirm that the flushing is complete turn off the water faucet and complete the commissioning Installation Instructions 9 Install the threaded flow limiting plug into the wastewater pipe Open the small ball valve to produce water Meanwhile open the water faucet to exhaust the air Wait until the water faucet is exhausted completely and close the faucet after the water flow is steady After ...

Page 11: ...water leakage and electric leakage may cause severe personal injury and property loss 5 Cut off the water and power when the water purifier will not be used for a long time When reusing the water purifier flush it according to the steps as using it for the first time If the water quality is unsatisfactory after flushing replace the filter cartridges as soon as possible 6 Cut off the power and wate...

Page 12: ...laces with large water consumption 1 Rotate the filter cartridge clockwise until it stops and the filter cartridge automatically comes off the filter adapter See Figure 5 in reverse direction 2 Select the corresponding replacement filter cartridge align the 2 connection pipes with the connections holes in the filter adapter and rotate counter clockwise until it stops see Figure 5 3 When replacing ...

Page 13: ...or without guidance of the manufacturer 4 Malfunctions or damages caused by improper use and breaking the rules of Instal lation Operation Manual 5 Malfunctions or damages caused by forced use under abnormal conditions such as the water pressure or voltage is too low or high 6 Product damage caused by human errors deliberately or accidentally 7 Damages caused by force majeure such as natural disas...

Page 14: ...al Front PP cotton filter cartridge Front activated carbon filter cartridge Rear activated carbon filter cartridge Reverse osmosis membrane filter cartridge Rear PP cotton filter cartridge 1 set 1 set 1 set 1 set 1 set 1 set 3 0 m 1 set Table 4 1 pcs Storage tank 1 pcs 1 pcs 1 pcs No 1 2 3 4 5 6 7 8 9 10 11 12 Accessories ...

Page 15: ...ell Environmental Combustion Controls Tianjin Co Ltd No 158 NanHai Road Tianjin Economic Technological Development Area Tianjin 300457 P R C Phone 86 22 66287000 Subject to change without notice 50085500 001 ...