background image

Usage Method

Filtered water

Tap water

Switch

Water segregator

Electronic device and application

Setting net water purification volume for cartridge:

Instructions on Digital Panel

4

Turning on for the first time after installation:

1. Turn the tap to fully-opened position.

2. The water segregator switch is in a “Purified” (i.e. purified water) position. The water 

will flow into the water purifier. Due carbon granules and air bubbles, the initial water 

flow will show slight turbidity. This is normal.

3. Continue to flush the water purifier for about 10 minutes until the water is clear 

without any air bubbles. The water can now be consumed.

Use the water segregator switch to select “PURIFIED” (purified water) or “TAP” (tap 

water).

•  When the water segregator is in the “PURIFIED” position, the water discharged is 

purified water.

•  When it is in the “TAP” position, the water discharged is municipal tap water.

Time (Day)

Flow rate (liter)

Button

Digital display

1) Under normal display status press the button for 3 seconds. The digital display will 

flicker to indicate that it is in "Setting" mode. Release the button to enter the "Setting" 

mode.

2) While in “Setting” mode the digital display will indicate the value last saved. The 

default value is “1500”.

Summary of Contents for HU-30

Page 1: ...Installation Operation Instruction Manual HU 30 Desktop Water Purifier Honeywell Environmental Combustion Controls Tianjin Co Ltd ...

Page 2: ......

Page 3: ...ortant Notes for Users 1 Safety Notices 1 Operation Instruction 2 Technical Parameter 2 Parts 3 Usage Method 4 Electronic device and application 4 Changing cartridge 5 Troubleshooting guide 7 Installation method 7 ...

Page 4: ...under any circumstances install the water purifier on water supply pipelines with a water pressure in excess of 0 6MPa If the water pressure for inlet water exceeds 0 6 Mpa pressure reduction valve to be separately purchased must be installed Temperature of inlet water should be 5 38 C Inlet water temperature exceeding 38 C may damage the sealing parts and cause leakage Inlet water temperature bel...

Page 5: ...nerally the idling period should not exceed 14 days If so change of cartridge is recommended If filtered water is to be obtained and stored pour it into a clean vessel and cover the vessel tightly Place the vessel in the refrigerator Water stored in this manner may be preserved for only two days Immediately cut off the water inlet for the water purifier by turning the water segregator to TAP posit...

Page 6: ... 7 Upper cover 6 Machine 4 Hose 2 Water segregator 10 Water outlet bend 9 Digital panel 1 Water segregator switch 3 Nut 5 Cartridge inside the machine 15 Cartridge Water segregator switch Water segregator Nut Hose Cartridge Machine Upper cover Top cover Digital panel Water outlet bend Bubbler Tightening nut Clip Foot pad ...

Page 7: ...lush the water purifier for about 10 minutes until the water is clear without any air bubbles The water can now be consumed Use the water segregator switch to select PURIFIED purified water or TAP tap water When the water segregator is in the PURIFIED position the water discharged is purified water When it is in the TAP position the water discharged is municipal tap water Time Day Flow rate liter ...

Page 8: ...wipe it dry with cloth or paper 4 During use the water purifier s display will alternate between flow rate liter and time day every 5 seconds If it is not in use the display panel s indicator light and display will be turned off after 20 seconds 5 The factory settings for the cartridge are 1 500 liters for flow rate and 180 days for time It is recommended that default setting be used changing of s...

Page 9: ...rtridge and remove it before placing the new cartridge in its place Press the new cartridge If the new cartridge is not properly aligned rotate it lightly to align it with the stopper in the machine Grip the cartridge When assembling the cartridge rotate it lightly to align it with the stopper 4 Screw the upper cover onto the machine and ensure that there is no gap 5 Flush the water purifier for a...

Page 10: ...any further 2 Make sure the washer is properly installed There is water leakage from the joint at the base of the machine between the connecting hose and the machine s water outlet 1 Is the hose properly installed 2 Is the clip properly fastened Re insert the purified water hose Reduced water volume from the tap and reduced volume of water from the water purifier s water outlet 1 Is the water segr...

Page 11: ...irst remove the screw on the metallic adapter using a Philip s head screwdriver cross screwdriver 2 Install the metallic adapter onto the water segregator nut 3 Use the cross screwdriver to lock the screw on the metallic adapter 4 Turn the nut on the water segregator but leave a gap of 3 4 mm 5 Forcefully push the water segregator onto the tap and tighten the screw using the screwdriver The metall...

Page 12: ... clip using the screwdriver If the tap has external groove thread and its diameter is 22 mm and the groove interval is 1 or 1 25 mm internal groove adapter may be used 1 Firstly remove the external groove cover from the tap 2 Install the internal groove adapter on the water segregator nut It is possible to use One Yuan coin to tighten the internal groove adapter onto the tap the adapter also has g...

Page 13: ... the hose tight with the water segregator s locking nut Connecting hose with the water filter 1 Insert the tube clip over the hose 2 Place the water filter upside down 3 Push the hose over the water filter s water outlet 4 Hold both ends of the clip and move it to the position indicated in the illustration Release the clip in order for it to clip the tube 5 Push to the clip to the position indicat...

Page 14: ...ttery 1 Shut the tap s inlet switch and remove the upper cover from the machine 2 Use a cross screwdriver to remove the screw on the face of the battery box 3 Remove the battery box cover and the No 7 batteries 2 units inside and replace them with new batteries 4 Re install the battery box s cover and tighten the screw Finally install the upper cover on the machine ...

Page 15: ......

Page 16: ...ll Environmental and Combustion Controls Tianjin Co Ltd Address No 158 Nanhai Road Tianjin Economic and Technological Development Zone Tel 022 66287000 The contents of this manual are subject to change without prior notice 50097009 001 REV A ...