HW7500E/HW7500EL Portable Electrical Generator Owner’s Manual
www.honeywellgenerators.com
17
Starting Generator
Manual (Recoil) Start
1.
Place generator outside in a well-ventilated area.
2.
Confirm the circuit breakers are set.
3.
Turn fuel shut-off valve to ON position.
4.
Pull choke control to ON position.
5.
Press engine control switch to RUN position.
6.
Grip recoil starter handle and pull slowly until you feel
slight resistance.
7.
Apply a swift pull to start the engine and carefully
return the recoil starter handle to its original position.
This may need to be repeated 2-3 times until the
engine starts.
8.
As engine warms up, and RPM stabilizes, gradually
push choke control to OFF position.
NOTICE
Keep the generator at a minimum of 6 feet (2 meters) from
any building, object, or wall.
FIGURE 23:
Circuit Breaker Position
FIGURE 24:
Fuel Shut-off Valve — ON/OFF position
FIGURE 25:
Choke Control
FIGURE 26:
Engine Control Switch
Set
Tripped
Set
Tripped
ON
OFF
START
ENGINE
STOP
RU
N
FIGURE 27:
Recoil Starter Handle
NOTICE
NEVER allow the starter grip to snap back against the
engine. Return it gently to prevent damage to the starter.
NOTICE
If engine will not start, move the choke to the OFF position
to reduce fuel to the engine.