Cleaning Spark Arrestor Screen
Cleaning Spark Arrestor Screen
Generator muffler is equipped with spark arrestor screen,
which must be cleaned according to maintenance sched-
ule (Table 2).
1.
Stop generator if engine is running. Allow to com-
pletely cool.
2.
Place the generator on a flat, level surface.
3.
Using a socket wrench with 8 mm socket, remove the
muffler cover bolts.
4.
Remove muffler cover.
5.
Loosen the spark arrestor clamp screw (A) with a slot-
ted screwdriver.
6.
Remove spark arrestor clamp.
7.
Using pliers remove the spark arrestor screen cover
(B) using a gentle rocking motion.
8.
Remove the spark arrestor screen (C).
9.
Inspect spark arrestor screen.
If screen is damaged or excessively worn, replace
with new screen.
If screen is in good condition, clean using wire
brush and then reinstall.
10.
Reinstall remaining spark arrestor components care-
fully aligning screw holes.
Screen cover
Clamp
Muffler cover
Transporting Generator
When transporting the generator:
•
Press engine control switch to OFF position.
•
Turn fuel shut-off valve to OFF position.
•
Keep generator level to prevent fuel spillage.
•
Be sure pins are in place in the handle and handle
bracket before moving generator.
Muffler reaches temperatures that can cause serious
burns if touched. NEVER touch hot surfaces.
To clean spark arrestor screen, you will need:
1/4” socket wrench
8 mm socket
Slotted screwdriver
Pliers
Wire brush
FIGURE 53:
Remove Muffler Cover
FIGURE 54:
Spark Arrestor Assembly
WARNING
A
B
C
FIGURE 55:
Clean Screen
Hot engine or exhaust system can cause serious
burns or fires. Cool generator completely before
transporting or storing.
NOTICE
NEVER drop, strike, or place heavy objects on generator
when transporting.
WARNING
Summary of Contents for HW7500E - Portable Generator NOT
Page 99: ... ...