background image

IDENT-KEY block lock
Item-No. 022220

Mounting and Connection Instructions

Contents

Page

1. Safety instructions .............................................14

2. General information ...........................................14

3. Connection diagram IDENT-KEY block lock......15

4. Installation of the block lock...............................16

5. Connection instructions .....................................21

6. Technical data....................................................22

7. Connection diagram ..........................................22

8. The program ......................................................23

Seite 1 bis 12

Page 13 to 24

Approval

G 196098

Subject to change
without notice

P00619-10-002-03

2008-10-01

D

GB

Summary of Contents for IDENT-KEY

Page 1: ... 1 Sicherheitshinweise 2 2 Allgemeines 2 3 Abmessungen IDENT KEY Blockschloss 3 4 Blockschloss Einbau 4 5 Anschlusshinweise 9 6 Technische Daten 10 7 Anschlussplan 10 8 Das Programm 11 P00619 10 002 03 2008 10 01 Seite 1 bis 12 Page 13 to 24 Anerkennung G 196098 Änderungen vorbehalten D GB ...

Page 2: ...hten Das Gerät darf nicht in explosionsgefährdeter Umgebung oder in Räumen mit metall oder kunststoffzersetzenden Dämpfen eingesetzt werden Das IDENT KEY Blockschloss dient als Schaltorgan zur Scharf Unscharf Schaltung von Einbruchmeldeanlagen in Verbindung mit den IDENT KEY Rosetten 022167 022169 Der Anschluss kann an die Auswerteeinheiten 022160 10 022160 20 022164 022200 oder 022200 10 erfolgen...

Page 3: ... 3 8 21 8 241 40 43 10 20 5 5 5 5 10 4 4 5 8 6 5 5 10 4 4 5 8 6 40 1 10 4 8 28 5 55 8 124 2 222 5 249 257 11 10 10 5 10 10 5 3 Abmessungen IK Blockschloss mit Standardstulp in mm Montage Anschluss Anleitung IK2 Blockschloss 3 ...

Page 4: ... Blockschlossleitung dass im oberen Tür bereich genügend Platz zum Einbau eines Reedkontaktes vorhanden ist Bevor das Blockschloss in die Blockschlosstasche geschoben wird muss die Rosette am Blockschloss angeschlossen werden Dabei muss das Flach bandkabel mit Stecker durch die Zylinderaussparung in die Blockschlosstasche und von dort nach außen geführt werden Der Flachstecker muss dann in der an ...

Page 5: ...e befestigt Beim muss darauf geachtet werden dass das Flach bandkabel der Rosette nicht beschädigt wird Anschließend Gewindehülsen Rosettenbefestigung endgültig anziehen 6 Kabelübergang montieren a Darauf achten dass die Schlauchbuchsen an den Enden des Metallschutzschlauches auf gesteckt sind Dadurch wird eine Beschädigung des Blockschlosskabels vermieden b Befestigungskappen festschrauben und da...

Page 6: ...ssung des Schließbleches an den Blockschlossriegel z B durch einen Schreiner oder Schlosser ist dadurch problemlos möglich Jetzt kann das Blockschloss über einen Profilhalbzylinder problemlos auf und zugeschlossen werden IK Auswerteeinheit mit Summer Türzarge Türblatt Schloss Kabelvorrat IK Blockschloss mit Dornmaßverlängerung Kabelübergang Kabel vom Blockschloss zur Auswerteeinheit konventionelle...

Page 7: ...uben befestigten Stulp entfernen Umrüstsatz bestehend aus Stulpabstandshalter Riegelverlängerung Riegelverschlussstopfen und Sicherungsschrauben entsprechend Zeichnung montieren Werkseitig eingesetzte Stulp Befestigungsschrau ben lösen Stulp austauschen und mit Einweg Sicherungsschrauben befestigen Die Riegelabdeck platte ebenfalls mit Einweg Sicherungsschrauben montieren Eine durchgeführte Montag...

Page 8: ...nmeldetechnischen Anlagen P03061 15 000 XX Die Blockschloss Aussparung muss so beschaffen sein dass bei einge setztem Blockschloss ein Abstand von 20 mm zwischen Blockschloss Stulp und der beweglichen Schubstange der Mehrfachverriegelung bestehen bleibt 20 mm Verriegelungsgestänge geöffnet vorhandenes Türschloss Verriegelungsgestänge geschlossen vorhandenes Türschloss Blockschloss Blockschloss Blo...

Page 9: ... eines IK Blockschlosses in eine Holztür mit Holzrahmen ist der Kabelschirm durchgehend von der Zentrale bis zum Blockschloss durchzuverbinden Beim Einbau des Blockschlosses in eine Metalltür oder Holztür mit Metallrahmen wird der Schirm in der Auswerteeinheit unterbrochen um eine Erdschleife zu vermeiden Bei einer Metalltür oder Holztür mit MetaIIrahmen ist auf eine korrekte Erdung zu achten Wenn...

Page 10: ...x T Gehäusetasche 16 x 210 x 40 mm Stulp 20 x 257 x 3 mm Riegel 11 x 40 mm Riegelausschluss 15 mm Schließblech 130 x 25 x 3 mm Schließbartstellung Profilhalbzylinder je nach Türanschlag 90 rechts bzw 90 links Das IK Blockschloss 022220 entspricht bei bestimmungsgemäßer Anwendung den grund legendenAnforderungen gemäßArtikel 3 der R TTE Richtlinie 1999 5 EG Die EG Konformitätserklärung steht auf uns...

Page 11: ... Nr 022169 IDENT KEY Rosette Art Nr 022180 Distanzstück 2 5 mm Art Nr 022182 Distanzstück 2 5 mm Farbe schwarz Farbe grauweiß ähnlich RAL9002 zwischenTürblatt und Rosette Farbe schwarz zwischenTürblatt und Rosette Farbe grauweiß ähnlich RAL9002 11 Montage Anschluss Anleitung IK2 Blockschloss ...

Page 12: ...P00619 10 002 03 2008 10 01 2008 Novar GmbH Honeywell Security Data Collection www honeywell com security de Novar GmbH Johannes Mauthe Straße 14 D 72458 Albstadt ...

Page 13: ...14 2 General information 14 3 Connection diagram IDENT KEY block lock 15 4 Installation of the block lock 16 5 Connection instructions 21 6 Technical data 22 7 Connection diagram 22 8 The program 23 Seite 1 bis 12 Page 13 to 24 Approval G 196098 Subject to change without notice P00619 10 002 03 2008 10 01 D GB ...

Page 14: ...ve to be observed The unit must no be used in explosion endangered environment or in rooms with metal or plastic decomposing vapours The IDENT KEY block lock serves as switching element for arming disarming of intrusion detection systems in combination with the IDENT KEY rosettes 022167 022169 The block lock can be connected to the evaluation units 022160 10 022160 20 022164 022200 or 022200 10 Th...

Page 15: ...1 8 241 40 43 10 20 5 5 5 5 10 4 4 5 8 6 5 5 10 4 4 5 8 6 40 1 10 4 8 28 5 55 8 124 2 222 5 249 257 11 10 10 5 10 10 5 3 Dimensions IK block lock with standard face plate in mm Mounting and Connection Instructions IK2 block lock 15 ...

Page 16: ...here is enough space for the installation of a reed contact in the upper door area when laying the block lock cable Before the block lock is slid into the block lock sleeve the rosette has to be connected to the block lock The flat band cable with plug must be passed through the cylinder recess of the block lock sleeve towards the outside Then the flat plug must be plugged into the socket provided...

Page 17: ...th the en closed screw When make sure that the flat band cable of the rosette is not damaged Then tighten the threaded sleeves rosette fixture completely 6 Install the cable passage a Take care that the hose sockets are plugged at the ends of the protective flexible metal hose Thus damage of the block lock cable is avoided b Tighten the fixing caps and make sure that the block lock cable is not da...

Page 18: ...e evaluation unit Thus the face plate can be adjusted easily to the block lock bolt e g by a carpenter or a locksmith Now the block lock can be locked and unlocked easily by means of the profile semi cylinder IK evaluation unit with buzzer Door frame Door leaf Lock Extra cable IK block lock with bolt extension Door loop Cable from block lock to evaluation unit Conventional connecting technology or...

Page 19: ...4 x 33 M5 x 70 80 M4 x 8 M4 x 48 M5 x 95 100 M4 x 8 M4 x 48 M5 x 115 The IK block lock bolt can be extended with the corresponding kit from 25 mm to bolt lengths of 35 mm 50 mm 55 mm 65 mm 80 mm and 100 mm Remove the face plate mounted at the factory with standard screws Conversion kit consisting of face plate spacer bolt extension bolt lock plug and securing screws mount all according to the draw...

Page 20: ...nstallation of hazard detection systems P03061 15 000 XX The block lock recess must be laid out so that there is a distance of 20 mm between block lock face plate and moving connecting rod of the multiple locking device when the block lock is inserted 20 mm Locking rods open Existing door lock Locking rods shut Existing door lock Block lock Block lock Locking screw Moving push rods Mounting and Co...

Page 21: ...o a wooden door with wooden frame the cable shielding must lead from the central unit to the block lock without interruption When mounting the block lock into a metal door or a wooden door with metal frame the shielding is interrupted in the evaluation unit in order to avoid grounding loop The correct grounding has to be observed for metal doors or wooden doors with metal frame If you are not sure...

Page 22: ... position any International protection acc DIN 40 050 IP30 Environmental class acc VdS III Dimensions W x H x D Housing sleeve 16 x 210 x 40 mm Keybit position profile semi cylinder Depending on door stop 90 right or 90 left The IK block lock 022220 complies with the essential requirements of the R TTE 1999 5 EC Directive if used for its intended use The EC Declaration of Conformity can be downloa...

Page 23: ... IDENT KEY rosette Item No 022180 Distance piece 2 5 mm Item No 022182 Distance piece 2 5 mm Color black Color greywhite similar to RAL 9002 Color black Color greywhite RAL 9002 between door leaf and rosette between door leaf and rosette similar to Mounting and Connection Instructions IK2 block lock 23 ...

Page 24: ...P00619 10 002 03 2008 10 01 2008 Novar GmbH Honeywell Security Data Collection www honeywell com security de Novar GmbH Johannes Mauthe Straße 14 D 72458 Albstadt ...

Reviews: