Magnetic Lock
Magnetic lock connected directly to the reader:
Fig. 27. Connections between reader and magnetic lock
1.
Connect 12VDC+ of the power supply to pin 4 (Relay-
NC) or pin 3 (Relay-C) of the reader and 12VDC- to the
-ve pin of the magnetic lock.
2.
Connect either pin 4 (Relay-NC) or pin 3 (Relay-C),
whichever is left free, of the reader to the +ve pin of the
magnetic lock.
In this setup, the door will remain locked as long as power is
provided and will unlock in the absence of power. If the reader
is powered off in this situation, the door will unlock.
NOTE:
The above describes one way of wiring the mag-
netic lock. Wiring must be done strictly as per the
stipulated safety codes that the building must
follow. Accordingly, the wiring would be either
done in a fail-safe or fail-secure configuration.
For description of reader pins refer to Table.5 and Table.6.