background image

IPGSM-4GC Commercial Fire Communicator – Installation and Setup Guide

 

 

– 

10

 – 

PowerBoost1 Information 

 

LED Indicator 

STATUS 

AC  (green) 

AC power available. 

ACTIVE  (green) 

Cyclical flashing – normal communications. 
Repetition of 3 flashes – loss of communications. 

LOW BATT  (yellow) 

Missing or low battery. 

TROUBLE  (yellow) 

One or more trouble conditions exist, such as; overload, output 
supervision, ground fault, or charger failure. 

 

Notes:

  

 

If AC power is lost and the battery voltage falls below 10v, the PowerBoost1 output voltage will be turned 
off.  The output power is turned back on when AC power is restored. 

 

You must use the DIP switch settings shown below. 

 

iPGSM-COM-003-

V

0

TROUBLE LED
I

N

DICATOR

PowerBoost1

1

5

O

N

2 3 4

Configure DIP s

w

itch

as sho

w

n:

AC LED
I

N

DICATOR

ACTI

V

E LED

I

N

DICATOR

LOW BATT LED
I

N

DICATOR

1

5

O

N

2 3 4

(S

w

itch handle = 

w

hite)

 

 

 

 

 

 

 

Summary of Contents for IPGSM-4GC

Page 1: ...er rc ci ia al l F Fi ir re e C Co om mm mu un ni ic ca at to or r I In ns st ta al ll la at ti io on n a an nd d S Se et tu up p G Gu ui id de e IPGSM 4GC Commercial Fire Communicator RADIO TROUBLE LOW BATT AC ON AC LOSS 800 12458 7 12 Rev C ...

Page 2: ... a Location 2 STEP 4 Mount and Wire 3 Wiring the 659EN Line Fault Monitor if required 6 STEP 5 Program the Communicator 7 STEP 6 Configure the Fire Panel 8 STEP 7 Test the System 8 Dialer Capture Module Information 9 LED Display Information 9 PowerBoost1 Information 10 Communicator Information 11 RF Specifications 12 Central Station Messages 12 IPGSM 4GC Trouble Detection Information 13 IPGSM 4GC ...

Page 3: ...inform the central station of this condition Operation The IPGSM 4GC replaces the fire panel s POTS communications path When an event occurs the fire panel goes off hook to dial the central station The IPGSM 4GC detects the off hook condition and provides the fire panel with a dial tone When the fire panel detects the dial tone it begins dialing the central station The IPGSM 4GC considers the thre...

Page 4: ...that can be used to register the communicator Register the communicator by logging into AlarmNet Direct and choosing Show Programmed Devices GSM I Search for the account using the Account Information or MAC ID Under the Actions column use the pulldown menu and choose Register OR After the IPGSM 4GC is installed and programmed you can register the communicator by clicking the Tamper Switch 3 times ...

Page 5: ...ely to the wall using 4 screws or bolts Use screws or bolts that are suitable for the material being anchored to 2 Ensure the cabinet door lock is installed 3 Install the two plastic mounting rails for the LED Display board They simply snap into the back plate holes 4 Connect the LED Display board to its connector then slide the board into the mounting rails Refer to the LED Display Information to...

Page 6: ...SM COM 008 V0 PowerBoost1 1 5 ON 2 3 4 1 5 ON 2 3 4 Switch handle white 12 Ensure the following LED Display board is fully seated All wiring terminals and connectors are tight All wiring has been completed and secured with cable ties 13 Install the battery not supplied Apply power to the 1451 UL9 Wired Transformer and attach the battery cable ...

Page 7: ...ERY 7AH Dialer Capture Module Telco 1 Telco 2 ECP Tip 2 Ring 2 ZN EOL EOL ZN PWR GND Tip 1 Ring 1 Data Out Data In 12V In GND Data Out RED GREEN 1451 UL9 WIRED TRANSFORMER 18 VAC 72 VA TO 24 HR FACILITY POWER BLU BLU GND POST WIRES MUST BE RUN IN CONDUIT TO Cabinet Ground Post TO PowerBoost1 BLU GND BLU PN 100 02415 Power Boost1 Module Tin wire ends DO NOT REMOVE these knockouts 120VAC 60Hz 850mA ...

Page 8: ...UT 1 DC to Power Boost 1 Terminal OUTPUT 1 DC to Power Boost 1 Terminal ERTH GND Wire to a Zone on the Fire Panel 659EN YEL ORG RED BLK GRN IPGSM 4GC 013 V0 4 7K 1 2 watt IPGSM 4GC Example wiring for an addressable fire control panel T11 T10 T9 T8 T7 T6 T1 T2 T3 T4 T5 1 0 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 0 2 3 4 5 6 7 8 9 TENS ONES LOOP ADDRESS TOP B A B A A B NO NC C TB2 TB5 SLC Loop FIRE LITE...

Page 9: ...D Enter number 01 FE then press 8 Primary Sub ID Enter number 0001 9999 then press Note If a Com Path Choice of IP GSM or IP was selected prompt 9 will appear 9 Use DHCP Y N Y If your router is configured for DHCP press Shift then Y then press Note If DHCP is not selected your router is set for a static IP prompts 10 through 13 will appear Use the Space key to advance to the next address part 10 N...

Page 10: ... prompt press Shift plus ESC Note setting the factory defaults will also erase any password that may have been entered Set Default Y N_ Press Y to reset factory default values Press N to cancel this function Press Shift then Y then The Create Password prompt appears follow the prompts then exit STEP 6 Configure the Fire Panel 1 Ensure the Phone Line Supervision or Telco Fault on the panel is enabl...

Page 11: ... when radio trouble is present Both IP and GSM communication paths are lost Communicator radio is not registered Old Alarm Time has been exceeded Message has not been delivered within the fixed 10 minute window Buzzer Upon loss of AC power this will beep once every 10 seconds LOW BATTERY Yellow ON when battery is low 11 5VDC Yellow not used AC LOSS Yellow ON when no AC is present 90VAC AC ON Green...

Page 12: ...re trouble conditions exist such as overload output supervision ground fault or charger failure Notes If AC power is lost and the battery voltage falls below 10v the PowerBoost1 output voltage will be turned off The output power is turned back on when AC power is restored You must use the DIP switch settings shown below iPGSM COM 003 V0 TROUBLE LED INDICATOR PowerBoost1 1 5 ON 2 3 4 Configure DIP ...

Page 13: ...ith the Dialer Capture Module MODULE S RECEIVED SIGNAL STRENGTH RSSI When the Mode Switch is NOT depressed LED 1 will illuminate red The remaining LEDs indicate RSSI Received Signal Strength MODULE S OPERATION MODE When the Mode Switch IS depressed LED 1 will be OFF LEDs 2 and 3 indicate the module s communication mode with the control panel Mode LED 2 yellow LED 3 yellow When the Mode Switch IS d...

Page 14: ...communication path multiple alarm Codes and their appropriate Restore Codes are reported to the Central Station IPGSM 4GC communicator fault The Fire Panel sends out a E380 and E352 message via Telco 1 these are then relayed to the central station via the IPGSM 4GC Telco line 1 fault The Fire Panel sends out a E380 and E351 message via Telco 2 these are then relayed to the central station via the ...

Page 15: ...ON Cabinet Dimensions Width 12 3 4 inches Height 14 7 8 inches Depth 3 inches Transformer 1451 UL9 Primary 120VAC 60Hz 850mA Secondary 18VAC 72VA Battery 12V 7Ah sealed lead acid type not supplied Use a Honeywell 712BNP Yuasa NP7 12 or equivalent Battery Charging Current maximum 1A Battery Discharge Current standby 230mA active 950mA Environment Operating temperature 20º to 55ºC for ULC installati...

Page 16: ...IPGSM 4GC Commercial Fire Communicator Installation and Setup Guide 14 NOTES ...

Page 17: ...IPGSM 4GC Commercial Fire Communicator Installation and Setup Guide 15 NOTES ...

Page 18: ...IPGSM 4GC Commercial Fire Communicator Installation and Setup Guide 16 NOTES ...

Page 19: ...IPGSM 4GC Commercial Fire Communicator Installation and Setup Guide 17 NOTES ...

Page 20: ...IPGSM 4GC Commercial Fire Communicator Installation and Setup Guide 18 NOTES ...

Page 21: ...IPGSM 4GC Commercial Fire Communicator Installation and Setup Guide 19 NOTES ...

Page 22: ...IPGSM 4GC Commercial Fire Communicator Installation and Setup Guide 20 NOTES ...

Page 23: ...BLK WHT GRN BLK RED CABINET DOOR FUSE GRA OPTIONAL CABINET TAMPER SWITCH BLK BATTERY BATTERY 7AH CONDUIT GRA AC ON To Facility Ground not supplied Use a Honeywell 712BNP Yuasa NP7 12 or equivalent To Router To Fire Panel To Fire Panel YEL Dialer Capture Module Telco 1 ECP Tip 2 Ring 2 ZN EOL EOL ZN PWR GND Tip 1 Ring 1 YEL GRN RED BLK Data Out RED GREEN To Fire Panel Main Dialer To Fire Panel Back...

Page 24: ...s to the receiver control Plug the receiver control into a different outlet so that it and the radio or television receiver are on different branch circuits Consult the dealer or an experienced radio TV technician for help INDUSTRY CANADA CLASS B STATEMENT This Class B digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada ...

Reviews: