Honeywell GmbH
12
MU1H-1417GE23 R0708
GB
13. Troubleshooting
*
CS = Customer services tel. 0 18 01 - 46 63 88
Problem
Cause
Remedy
No water supply to the device
Shut-off device in the bypass is not
open or only partially open
Open shut off valve fully
Pipework of the drinking water supply
is calcified or blocked
Clean or replace the pipework
Device does not regenerate
Flow meter is defective
Check and, if necessary, replace the
flow meter (CS*)
Internal electric cabling is defective
Check internal electric cabling (CS*)
Wrong connection of connecting hosesConnect the flexible connection lines
correctly
Rotary disc valve defective
Call Technical Customer Service
Nothing is displayed
Power supply has been interrupted
Check power suppy (mains plug, fuse)
Rotary disc valve defective
Call Technical Customer Service
Incorrect time is displayed
Power failure occurred
Set the time
Insufficient function
Device not deaerated
Deaerate device
Storage tank is almost or completely
empty
Check salt level
Blending has been set incorrectly
Check blending valve and mixing ratio
Control valve is contaminated or
defective
Call Technical Customer Service
14. Disposal
• High quality synthetic material housing
• All components subject to pressure in glass-fibre-
reinforced plastics
• All components to brine in Noryl
15. Spare Parts
16. Accessories
Observe the local requirements regarding
correct waste recycling/disposal!
No. Description
Part No.
1
Disinfection unit
DE10S-A
2
Controller head seal kit
EK10S-A
3
Spare part kit for brine pump
EK10S-B
4
O-ring set
EK10S-C
5
Turbine water counter
EK10S-D
D06F
Pressure reducing valve
Noise protected pressure reducing valve
with setting scale. Maximum inlet pressure
16 bar, with brass filter bowl 25 bar, outlet
pressure range 1.5 - 6.0 bar
A = With clear filter bowl up to 40 °C / 16 bar
B = With brass filter bowl up to 70 °C / 25 bar
F76S
Fine filter, reverse rinsable
AA = With clear filter bowl
AAM= With red bronze filter bowl
OFV10S-A Bypass valve insert
if a pressure scourer is applicated it is
neccessary to fit a bypass valve insert into
the bypass valve.