Summary of Contents for LP1501

Page 1: ...Sep 2020 2020Honeywell All rights reserved 800 26497 PW7K1ICE Intelligent Controller LP1501 Installation and Configuration Guide ...

Page 2: ...the right to change any information in this document at any time without prior notice Microsoft and Windows are registered trademarks of Microsoft Corporation Windows Server is a trademark of Microsoft Corporation Ordering Information Please contact your local Honeywell Integrated Security representative or visit us on the web at www honeywellintegrated com for information about ordering Feedback ...

Page 3: ... 4 DIP Switch Configuration 17 2 5 Factory Default Communication Parameters 17 2 6 Bulk Erase Configuration Memory 18 2 7 Bulk Erase Steps 18 2 8 Input Power 18 2 9 Communication Wiring 19 2 10 Reader Wiring 19 2 11 Input Circuit Wiring 22 2 12 Relay Circuit Wiring 22 2 13 Memory Backup Battery 23 2 14 Status LEDs 24 2 15 IT Security 25 2 16 Specifications 25 2 17 Additional Mounting Information 2...

Page 4: ...ww honeywell com Device Info Screen 40 Users Screen 41 Auto Save Screen 42 Restore Default Screen 42 Load Certificate Screen 43 3 4 Initializing the System and Performing a System Download 44 3 5 Logout 46 ...

Page 5: ...Document 800 26497 5 1 PW7K1ICE Introduction In this chapter 1 1 Overview 6 1 2 General UL Compliance 7 1 3 CE WEEE Marking 8 1 5 Access Control 10 1 6 Card Formats 11 1 8 Alarm Management 13 1 9 Warranty 14 1 10 Liability 15 1 11 FCC Compliance 16 ...

Page 6: ...S 485 electrical signaling such as an OSDP reader standards one or two wire LED controls and buzzer control one wire LED mode only This port can also utilize multiple RS 485 multi dropped devices The second reader port can accommodate readers that utilizes Wiegand or magnetic stripe signaling one or two wire LED controls and buzzer control one wire LED mode only Two form C relay outputs may be use...

Page 7: ...have been evaluated for use with this system This product is intended to be installed indoors within the protected premises Access Control System Model PRO4200 and Controller Model PRO42IC meet the requirements for CAN ULC S319 05 Equipment Class 1 This product s compliance to ULC S319 Electronic Access Control Systems will be considered invalidated through the use of any add on expansion memory o...

Page 8: ...EE Marking Stick the CE label from accessories onto the enclosure Description of the used symbol CE Standard Logo This product complies with the harmonized Regulation of the EU WEEE symbol It indicates this product is to be recycling and not been thrown in the dustbin ...

Page 9: ... Document 800 26497 9 1 4 Door Control One 1 physical barrier can be controlled using single or paired readers Two reader ports Mag Wiegand or RS 485 RS 485 on one reader port capable of supporting two readers Two supervised inputs two relays Diagnostic LEDs Dedicated tamper input ...

Page 10: ...nsaction buffer software configurable 12 to 32 Access Levels per cardholder software configurable Card Number 19 digit 64 bit User Id with 15 digit PIN numbers MAX Activation Deactivation Dates Macro capability using IF and THEN logic Anti Passback support with Nested Area and Hard Soft or Timed Forgiveness ...

Page 11: ...PW7K1ICE Introduction Card Formats PW7K1ICE Installation and Configuration Guide Document 800 26497 11 1 6 Card Formats 8 active card formats per PW7K1ICE PIV II CAC TWIC card compatible ...

Page 12: ...e following Listed ALVY card readers Manufacturer Model Part Number HID ProxPro HU 5355AGN00 ProxPro II HU 5455BGN00 ProxPro K HU 5355AGK00 MiniProx HU 5365EGP00 ThinLine II HU 5395CB100 HU 5395CG100 HU 5395CK100 Honeywell OM40 OM40BHONC OM40GHONC OM41 OM41BHONC OM41GHONC OM55 OM55BHONB OM55GHONB OP 10 OP10GENR OP10HONR OP 30 OP30GENR OP30HONR OP 40 OP40GENR OP40HONR ...

Page 13: ...troduction Alarm Management PW7K1ICE Installation and Configuration Guide Document 800 26497 13 1 8 Alarm Management Normally open Normally closed unsupervised supervised Standard or custom end of line resistances ...

Page 14: ... to the repair or replacement of the defective unit There are no expressed warranties other than set forth herein Honeywell Security Access does not make nor intends nor does it authorize any agent or representative to make any other warranties or implied warranties and expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose Returned units are...

Page 15: ...native method for exit is available This product is not intended for nor is rated for operation in life critical control applications Honeywell Security Access is not liable under any circumstances for loss or damage caused by or partially caused by the misapplication or malfunction of the product Honeywell Security Access s liability does not extend beyond the purchase price of the product ...

Page 16: ...liance This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation ...

Page 17: ...ns 19 2 3 Jumper Configuration 20 2 4 DIP Switch Configuration 21 2 5 Factory Default Communication Parameters 21 2 6 Factory Default Details 22 2 8 Input Power 22 2 9 Communication Wiring 23 2 10 Reader Wiring 23 2 11 Input Circuit Wiring 26 2 12 Relay Circuit Wiring 26 2 13 Memory Backup Battery 27 2 14 Status LEDs 28 2 16 Specifications 29 2 17 Additional Mounting Information 32 ...

Page 18: ...18 www honeywell com PW7K1ICE Wiring and Setup PW7K1ICE Hardware 2 1 PW7K1ICE Hardware Figure 2 1 PW7K1ICE Control Board ...

Page 19: ...See Note 1 TB2 5 DAT Reader 1 DAT Data 0 TR A See Note 1 TB2 6 GND Reader 1 Ground TB3 1 LED Reader 2 LED Output TB3 2 BZR Reader 2 Buzzer Output TB3 3 CLK Reader 2 CLK Data 1 Input TB3 4 DAT Reader 2 DAT Data 0 Input TB4 1 VO Auxiliary Power Output 12VDC TB4 2 GND Auxiliary Power Output Ground TB4 3 VIN Input Power 12VDC from local power supply TB4 4 GND Input Power Ground TB5 1 NO Relay K1 Norma...

Page 20: ...per Set at Description J1 N A Factory Use Only J3 PoE PW7K1ICE powered from the Ethernet connection 12V PW7K1ICE powered from an external 12VDC power source connected to TB4 3 VIN TB4 4 GND J4 N A Factory Use Only J5 N A Micro USB Port 2 0 J6 N A 10 Base T 100Base Tx Ethernet Connection Port 0 J7 Cabinet Tamper normally open switch J8 N A Micro SD Card ...

Page 21: ... password The switch is read on the fly no need to re boot See IT security section for additional information OFF ON X OFF Use factory default communication parameters ON ON X OFF Use OEM default communication parameters Contact system manufacture for details See Bulk Erase below ON ON OFF OFF Bulk Erase prompt mode at power up See Bulk Erase below X X X ON Makes the LP1501 report and function lik...

Page 22: ...ithin 10 seconds after the above pattern starts change switches 1 or 2 to OFF If these switches are not changed the LP1501 board will power up using the OEM default communication parameters 5 LED 2 will flash indicating that the configuration memory is being erased 6 Full memory erase takes up to 60 seconds usually a lot less 7 When complete only LEDs 1 4 will flash for about 3 seconds 8 The LP150...

Page 23: ... may be powered from the 12 VDC auxiliary power supply output TB4 1 and TB4 2 Readers that require different voltage or have high current requirements should be powered separately Refer to the reader manufacture specifications for cabling requirements In the 2 wire LED mode the buzzer output is used to drive the second LED Reader port configuration is set via the host software Reader port 1 can su...

Page 24: ...24 www honeywell com PW7K1ICE Wiring and Setup Reader Wiring Inputs on supervised F 2F readers may be unsupervised or supervised shown Caution Jumper D1 and LED on supervised F 2F readers ...

Page 25: ...PW7K1ICE Wiring and Setup Reader Wiring PW7K1ICE Installation and Configuration Guide Document 800 26497 25 ...

Page 26: ...upervised input circuit requires two resistors be added to the circuit to facilitate proper reporting The standard supervised circuit requires 1K Ohm 1 resistors and should be located as close to the sensor as possible Custom end of line EOL resistances may be configured via the host software Note Grounded and foreign voltage states are not a requirement of UL 294 and therefore not verified by UL ...

Page 27: ... Auxiliary output the LP1501 can provide 12 VDC power for external devices provided that the maximum current is not exceeded See the specifications section for details If a local power supply is used it must be UL Listed Class 2 rated Figure 2 5 Relay Circuit Wiring Diagram 2 13 Memory Backup Battery The SRAM is backed up by a rechargeable battery when input power is removed This battery should re...

Page 28: ...actory Default Details page 22 see section 4 If clearing the memory does not correct the initialization problem contact technical support Running After initialization is complete the meaning of the various ways in which the LEDs flash is described in Table 2 5 At power up LEDs 2 through 7 are first turned ON then OFF in sequence Table 2 5 LED Descriptions LED DESCRIPTION 1 Off Line On Line and Bat...

Page 29: ...least one user account is defined and the DIP switches are set to OFF before the LP1501 is commissioned It is also highly recommended not to configure the LP1501 with an IP address that is accessible from the public Internet To further enhance network security options are available to disable SNMP Zeroconf discovery as well as the web configuration module itself Additionally data encryption can al...

Page 30: ...B Host Communica tion Ethernet 10BaseT 100Base TX and Micro USB port 2 0 with optional adapter pluggable model USB2 OTGE100 Inputs 2 supervised Programmable End of Line resistors 1k 2k ohm 1 1 4W watt standard and dedicated tamper input Relays 2 outputs Form C contacts 2A 30VDC Reader Interface Reader Power PoE 12 VDC 10 or local power supply 12VDC PTC limited 300mA max Reader Data Inputs Two TTL ...

Page 31: ...resistance Reader data TTL 18AWG 6 conductors 500 foot 152 m maximum Reader data F 2F 4 conductor 18 AWG 500 ft 152 m maximum Reader data RS 485 24AWG 120 ohm impedance Twisted pair with shield 2000 foot 610 m maximum Output As required for the load Environmental Temperature 0 to 70 C operating 55 to 85 C storage Humidity 5 to 95 RHNC Mechanical Dimensions 5 5 140mm W x 2 75 70mm L x 0 96 24mm H w...

Page 32: ...ion 2 17 Additional Mounting Information Sources for the optional items are shown below 3 gang stainless steel blank cover Leviton part number 84033 40 Available from Graybar part number 88158404 Magnetic switch set G R I part number 505 Figure 2 6 Stainless Steel Blank Cover ...

Page 33: ...ing Information PW7K1ICE Installation and Configuration Guide Document 800 26497 33 Figure 2 7 Mounting Plate Dimensions 3 85 97 8 2 35 59 7 5 50 139 7 3 63 92 1 3 30 83 8 3 63 92 1 Ø0 16 Ø4 0 MR50 MGT HOLES 4PL Ø0 16 Ø4 0 3 GANG MGT HOLES 4PL ...

Page 34: ...34 www honeywell com PW7K1ICE Wiring and Setup Additional Mounting Information This page is left blank intentionally for double sided printing ...

Page 35: ... to ACDSM for the First Time 36 3 2 Login 37 3 2 1 Security Certificate 38 3 3 Web Server Configuration 41 3 3 1 Home Screen 41 3 3 3 Host Communication Screen 43 3 3 4 Device Info Screen 44 3 3 5 Users Screen 45 3 3 6 Auto Save Screen 46 3 3 7 Restore Default Screen 46 3 3 8 Load Certificate Screen 47 3 4 Initializing the System and Performing a System Download 48 ...

Page 36: ... server is 192 168 0 251 3 1 1 Connecting to ACDSM for the First Time 1 Use the factory default controller IP address 192 168 0 251 2 Set the DIP switches to S4 OFF S3 OFF S2 ON S1 OFF 3 Connect the computer to host the web server via Ethernet Port 0 Connection should be via crossover Ethernet cable or by the regular Ethernet cables connected via the hub 4 Set the host computer to the static IP ad...

Page 37: ...display the User Name and Password fields Figure 3 1 Configuration Manager Login Screen If DIP Switch 1 is ON then set Default Username to admin and Default Password to password This switch is read on the fly There is no need to reboot the controller If the security certificate of your server is not valid continue with the next step Security Certificate on page 38 If the security certificate of yo...

Page 38: ...If there is a problem with your security certificate the system will display the following message Figure 3 2 Security Certificate Warning Screen If the security certificate of your server is not valid the system will display the following warning message Figure 3 3 Security Certificate Invalid Message ...

Page 39: ...t 800 26497 39 1 To download a valid security certificate click the About Certificate Errors link and display the certificate properties screen Figure 3 4 Security Certificate Information Screen 2 Click Install Certificate to launch the Certificate Import Wizard Figure 3 5 Security Certificate Import Wizard ...

Page 40: ... Certificate Store Screen 4 Select Automatically Select the certificate store based on the type of certificate option button and click Next to display the completion screen Figure 3 7 Security Certificate Import Completion Screen 5 Click Finish to display the Login Enabled confirmation message Figure 3 8 Login Enabled Confirmation Screen ...

Page 41: ...Click OK to log in to the configuration screen and resume the configuration process 3 3 Web Server Configuration Complete the login by entering your User Name and Password 3 3 1 Home Screen The system will display the Home screen which has all the available configuration links on the left navigation bar Figure 3 9 Configuration Manager Screen ...

Page 42: ...Settings screen where you can configure the IP address and hostname information Figure 3 10 Network Settings Screen 2 Click the Use Static IP Configuration option button to assign a static IP address and enter the following information in the appropriate fields IPAddress Subnet Mask Default Gateway 3 Enter the appropriate IP address for the DNS Server field 4 Click Accept to save the settings ...

Page 43: ... addresses for the PW7K1ICE board 3 For the Primary Host Port make the following selections a Connection Type Select IP Server b Data Security Select one of the following values from the drop down list None Password AES c Port Number Enter the port number through which the host computer can communicate with the PW7K1ICE board d Select either Allow All or the Authorized IPAddress Required option bu...

Page 44: ...IP Client b Data Security Select one of the following values from the drop down list None Password AES c Select a Baud Rate from the drop down list d Select a Flow Control from the drop down list 5 Click Accept to save the settings 3 3 4 Device Info Screen 1 Click the Device Info link on the navigation bar to display the read only Device Information screen where you can view all the device informa...

Page 45: ...dium Password Strength minimum of 6 characters and passes two of the password strength tests High Password Strength minimum of 8 characters passes three of the password strength tests and password not based on user name The following strong password requirements are based on Microsoft guidelines for creating strong passwords Password Strength Tests contains characters from any of the following cat...

Page 46: ...e link on the navigation bar to display the Auto Save screen Figure 3 14 Auto Save Configuration Screen 2 Select one of the following option buttons in case you lose changes made prior to reset Restore from the last saved settings Clear all settings and force a full download 3 Select Enable for Auto Save and select a Delay Before Save time value from the drop down list 4 Click Save Settings 3 3 7 ...

Page 47: ...settings for all the configuration variables 3 Click Restore Current to reload the current operational settings for all the configuration variables 3 3 8 Load Certificate Screen 1 Click the Load Certificate link on the navigation bar to display the Load Certificate screen Figure 3 16 Load Certificate Screen 2 Locate the Certificate File and Private Key File by clicking the respective Browse button...

Page 48: ...ializing the System and Performing a System Download After creating the PW6KICE EP1501 panel initialize the system and perform a system download 1 Right click on the panel and select Download 2 Clear the Download System check box see Figure 3 17 on page 49 and select the Initialize check box 3 Click Download see Figure 3 17 on page 49 ...

Page 49: ... 17 Panel Download 4 Right click on the panel again and select Download This time keep Download System checked and click Download The panel will be initialized and Pro Watch will trigger a system download After you add a PW6K1R1E downstream board to the PW6KICE you must set the panel s MAC address and IP address see Figure 3 18 Note MAC address octets must be separated by a colon ...

Page 50: ...www honeywell com PW7K1ICE System Configuration via Web Interface Logout Figure 3 18 Setting MAC address and IP address 3 5 Logout Click Log Out to complete the web server configuration process and log out ...

Page 51: ... This page is left blank intentionally for double sided printing ...

Page 52: ...y 135 W Forest Hill Avenue Oak Creek WI 53154 414 766 1700 414 766 1798 Fax European Office Boblingerstrasse 17 D 71101 Schonaich Germany 49 7031 637 782 49 7031 637 769 Fax www honeywell com Specifications subject to change without notice Honeywell All rights reserved 800 26497 ...

Reviews: