36
www.honeywell.com
PW7K1ICE System Configuration via Web Interface
Overview
3.1 Overview
PW7K1ICE comes with
Access Control Device Server Manager (ACDSM)
; i.e., a
built-in web server through which the users can configure their network and other
system settings.
Note:
The default factory-set TCP/IP address for the built-in system configuration web
server is
192.168.0.251
3.1.1 Connecting to ACDSM for the First Time
1. Use the factory default controller IP address
192.168.0.251
.
2. Set the DIP switches to
S4=OFF
,
S3=OFF
,
S2=ON
,
S1=OFF
.
3. Connect the computer to host the web server via Ethernet
Port 0
. Connection
should be via crossover Ethernet cable or by the regular Ethernet cables
connected via the hub.
4. Set the host computer to the static IP address
192.168.0.250
to be able to
connect to the factory-default PW7K1ICE controller at address
192.168.0.251
.
5. Power up the PW7K1ICE controller.