LYNX Touch Installation and Setup Guide
- 67 -
LYNX Touch (L5100CN) Canada Programming Default Values
Program Function
Configuration 1
Configuration 2
Configuration 3
Configuration 4
Downloader
Phone
Answer
Yes Yes Yes Yes
Ans. Machine Defeat
Yes
Yes
Yes
Yes
Modem Speed (Future Use)
Slow
Slow
Slow
Slow
Ring Counter
2
2
2
2
Callback Number
Blank
Blank
Blank
Blank
Flexible Callback
No
No
No
No
Number 1
1
1
1
Sounder
Burglary Alarm Sound
Yes
Yes
Yes
Yes
Burglary Bell Timeout
4 Minutes
4 Minutes
4 Minutes
4 Minutes
Fire Bell Timeout
4 Minutes
4 Minutes
4 Minutes
4 Minutes
Arm Confirm
None
None
None
None
Alarm Options
Unlimited
2
2
2
System Settings
Entry Delay 1
30 Seconds
45 Seconds
30 Seconds
30 Seconds
Entry Delay 2
60 Seconds
60 Seconds
60 Seconds
60 Seconds
Exit Delay
60 Seconds
60 Seconds
60 Seconds
60 Seconds
Backlight
Timeout
No No No No
Quick
Arm
Yes Yes Yes Yes
Quick
Exit
Yes Yes Yes Yes
Restart Exit Time
No
Yes
Yes
Yes
Force
Bypass
No No No No
Exit Warning
No
Yes
Yes
Yes
Auto Stay Arming
No
Yes
Yes
Yes
Lack Of Usage Notify
Disabled
Disabled
Disabled
Disabled
Power-Up In Previous
Yes
Yes
Yes
Yes
Display Alarm Cancel
No
Yes
Yes
Yes
Display Exit Time
Yes
Yes
Yes
Yes
Cross Zone Delay
3 Minutes
None
None
None
Cross Zone 1
Disabled
Disabled
Disabled
Disabled
Cross Zone 2
Disabled
Disabled
Disabled
Disabled
Z-Wave
Z-Wave
Enabled-Installed Enabled-Installed Enabled-Installed Enabled-Installed
Temperature
Fahrenheit Fahrenheit Fahrenheit Fahrenheit