LYNX Touch Installation and Setup Guide
- 79 -
5100-100-SOC-V1
2K
OHM
EOLR
PO
WER SUPPL
Y
CONNECT
OR
HARD
WIRED
ZONE
WEEKL
Y
TESTING IS REQ
UIRED
T
O ENSURE
PR
OPER OPERA
TION OF
THIS SYSTEM
PREMISES
TELEPHONE
INCOMING
PHONE LINE
INCOMING
PHONE LINE
H/S T
H/S R
RING
TIP
EGND
EARTH GR
OUND
HWZ1
TRIG
GND
GND
+9VDC
300-04705 or 300-04065
(300-04063 CANAD
A)
PO
WER SUPPL
Y
9V
, 2.7A
STANDARD CAPACITY
BATTERY CONNECTOR
SUPER HIGH CAPACITY
BATTERY CONNECTOR
L
YNX
T
OUCH SERIES SUMMAR
Y OF CONNECTIONS
ZONES
POWER
PHONE
TRIGGER OUTPUT (NEG)
(3ma)
THIS DEVICE COMPLIES
WITH P
AR
T 15 OF FCC R
ULES
. OPERA
TION IS
SUBJECT
T
O
THE FOLLO
WING
TW
O CONDITIONS:
(1)
THIS DEVICE MA
Y
NO
T CA
USE HARMFUL INTERFERENCE, AND (2)
THIS DEVICE MUST
A
CCEPT ANY INTERFERENCE RECEIVED
, INCLUDING INTERFERENCE
THA
T MA
Y CA
USE UNDESIRED OPERA
TION.
THIS EQ
UIPMENT SHOULD BE INST
ALLED IN A
CCORD
ANCE
WITH
THE NA
TIONAL FIRE
PR
O
TECTION ASSOCIA
TION ST
AND
ARDS ANSI/NFP
A 70 NA
T
ONAL ELECTRIC CODE AND
NFP
A 72 NA
TIONAL FIRE ALARM CODE, CHAPTER 2 (NA
TIONAL FIRE PR
O
TECTION
ASSOC
., BA
TTER
Y MARCH P
ARK, Q
UINCY
, MA 02169).
PRINTED INFORMA
TION
ESCRIBING PR
OPER INST
ALLA
TION, EV
A
CU
A
TION PLANNING AND REP
AIR SER
VICE IS
T
O
BE PR
O
VIDED
WITH
THIS EQ
UIPMENT
.
THE L
YNX
T
OUCH CONTR
OLS ARE COMP
A
TIBLE
WITH
THE
FOLLO
WING INTEGRAL RECHARGEABLE BA
TTER
Y P
A
CKS:
REPLA
CE EVER
Y FOUR
YEARS
P/N 300-03864-1/L
YNXRCHKIT
-SC
P/N 300-03866/L
YNXRCHKIT
-SHA
COMPLIES
WITH FCC R
ULES
, P
AR
T 68 FCC REGISTRA
TION
No
. A
C3AL05BL5000
RINGER EQ
UIV
ALENCE:
0.5B
RING
TIP
RING
TIP
TAMPER
SWITCH
TELCO
JACK
EDGE
CONNECTOR
(L5100-WiFi)
EDGE
CONNECTOR
(L5100-
ZWAVE)
GSMVLP5-4G/GSMVLP5CN4G/
ILP5 RECEPTACLE
NOTE:
THE HARDWIRE ZONE CANNOT BEUSED AS A FIRE ZONE.
UL INST
ALLA
TIONS
THE MINIMUM
WIRE
SIZE USED FOR
TELEPHONE
INST
ALLA
TIONS
MUST BE #26 GA
GE
W
ARNING
T
O PREVENT RISK OF
SHOCK, DISCONNECT
TELEPHONE LINE
A
T TELECOM
J
A
CK
BEFORE SER
VICING
THIS UNIT
LYNX
T
OUCH SERIES ALSO COMPLIES
WITH
THE FOLLO
WING:
CANADIAN ST
AND
ARDS ASSOCIA
TION (CSA) C22.1,
CANADIAN ELECTRICAL CODE, P
AR
T 1, SAFETY ST
AND
ARD
FOR ELECTRICAL INST
ALLA
TIONS AND CAN/ULC-S540
INST
ALLA
TION OF RESIDENTIAL FIRE
W
ARNING SYSTEMS
.
CIRCUIT
(ZONE)
CONTROL UNIT
DELAY-SEC
SMOKE DETECTOR
MODEL DELAY-SEC
THIS UNIT MAY BE PROGRAMMED TO INCLUDE AN ALARM
VERIFICATION FEATURE THAT WILL RESULT IN A DELAY OF THE
SYSTEM ALARM SIGNAL FROM THE INDICATED FIRE CIRCUITS.
THE TOTAL DELAY (CONTROL UNIT PLUS SMOKE DETECTORS)
SHALL NOT EXCEED 60 SECONDS. NO OTHER INITIATING
DEVICES SHALL BE CONNECTED TO THESE CIRCUITS UNLESS
APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION.
WARNING
5806W3
10 seconds
30 seconds
02 - 48
ZT16
Be sure to obser
v
e
polar
ity when
connecting the
po
w
er supply to
the ter
minal str
ip
.
IMPOR
T
ANT
Notes:
Connection of the fire alarm signal to a fire alarm headquarters or a central station shall be permitted with the
approval of the local authority having jurisdiction. The burglar alarm signal shall not be connected to a police
emergency number. The System must be checked by a qualified technician once every three years