LYNX Touch Series Control
Quick Installation Guide
This Quick Installation Guide can help you install the rechargeable LYNX Touch Series Control quickly and easily by providing the basic steps for installation using the built-in defaults.
FOR DOCUMENTATION AND ONLINE SUPPORT:
http://www.security.honeywell.com/hsc/resources/MyWebTech
(see LYNX Touch Series Installation and Setup
Guide P/N 800-10614 or higher.) A copy of the Installation and setup Guide may also be requested from Honeywell.
WARRANTY INFORMATION
For the latest warranty information, please go to:
www.honeywell.com/security/hsc/resources/wa
1. Install the Control
TERMINAL
STRIP
POWER
SUPPLY
RECEPTACLE
BACK
CASE
TAMPER
SWITCH
TELEPHONE
CONNECTIONS
EDGE
CONNECTOR
WIRE ROUTING
CLIPS (3)
MOUNTING
HOOKS
(HINGES)
5100-100-078-V0
LOCKING TABS
FRONT
CASE
ROTATE
FRONT CASE
UPWARD
TO RELEASE
HOOKS
EDGE
CONNECTOR
GSMVLP5-4G/ILP5
RECEPTACLE
ILP5 RECEPTACLE
KNOCKOUT
ILP5
SPACER
BATTERY
CABLE CHANNEL
TIE WRAP
POINTS (3)
MOUNTING
HOLES (4)
TIE WRAP
POINTS (2)
INSTALL
SCREW
IN CASE
TAMPER
CASE
TAMPER
DETAIL A
2. Make Wiring Connections
5100-100-076-V0
2K
OHM
EOLR
POWER SUPPLY
CONNECTOR
HARD
WIRED
ZONE
WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM
PREMISES
TELEPHONE
INCOMING
PHONE LINE
INCOMING
PHONE
LINE
H/S
T
H/S R
RING
TIP
EGND
EARTH
GROUND
HWZ1
TRIG
GND
GND
+9VDC
300-04705 or 300-04605
(300-04063 CANADA)
POWER SUPPLY
9V, 2.7A
STANDARD CAPACITY
BATTERY CONNECTORS
SUPER HIGH CAPACITY
BATTERY CONNECTOR
ZONES
POWER
PHONE
EDGE CONNECTOR
(L5100-ZWAVE)
EDGE CONNECTOR
(L5100-WiFi)
TRIGGER OUTPUT (NEG)
(3ma)
RING
TIP
RING TIP
TELCO
JACK
UL NOTE
THE MINIMUM WIRE SIZE USED FOR TELEPHONE
INSTALLATIONS MUST BE #26 GAGE
OBSERVE POLARITY WHEN
CONNECTING THE POWER
SUPPLY TO THE TERMINAL STRIP.
WARNING
TO PREVENT
RISK OF SHOCK,
DISCONNECT
TELEPHONE LINE
AT TELECOM
JACK BEFORE
SERVICING
THIS UNIT
NOTE
USE ONLY THE
300-04705/300-04605
OR 300-04063
POWER SUPPLY
PROVIDED
ALL OUTPUT CIRCUITS ARE POWER LIMITED.
GSMVLP5-4G/ILP5
RECEPTACLE
Note:
For the complete Summary of Connections, refer to the LYNX
Touch Series Installation and Setup Guide P/N 800-10614 or
higher.
3. Install the Communications Module
SIM CARD
5100-100-077-V0
ROTATED
180
ROTATED
180
CONNECTOR
BOARD
CONNECTOR BOARD
CONNECTOR BOARD
RECEPTACLE
LYNX TOUCH
TIE
WRAP
POINT
NOTE:
SIM CARD INSTALLED
IN GSMVLP5 ONLY
REMOVE
ILP5
SPACER
ILP5
SPACER
REMOVE
ILP5
KNOCKOUT
TIE
WRAP
(1)
LYNX TOUCH
ALTERNATE INSTALLATION
RJ45
RECEPTACLE
RJ45 RECEPTACLE
ETHERNET CABLE
GSMVLP5-4G
SCREW
(3)
ILP5
TO ILP5
Ensure that SIM card and the connector board are securely
installed in the communications module before installing it
in the LYNX Touch.
4. Make Battery Connections
5000-100-01
8
-
V
1
LYNXRCHKIT-SHA
(P/N 300-03866)
OR
RETAI
N
ER
SCRE
W
RETAI
N
ER
LYNXRCHKIT-SC
(P/N 300-03864-1)
SCRE
W
1. Release the front case from the rear case by depressing the two
locking tabs at the top of the unit with the blade of a medium size
screwdriver.
2. Separate the front and back case assemblies by rotating the front
case so that it is perpendicular to the rear case and unsnapping
(releasing) the two hooks (hinges) from the back case.
3. Feed the wiring through the appropriate openings in the back
case. Use tie wraps to secure the wiring to the built-in wire loops
as needed.
4. Mount the back case to a sturdy wall and secure with the provided
screws.
5. If required, install an additional mounting screw in the case
tamper (see Detail A).
6. Attach the front and back cases by connecting the hooks on the
front case to the attachments on back case. Once attached, the
hooks will support the front case and allow you to make the wiring
connections.
7. After all of the wiring connections have been made, snap the front
case and back case closed and ensure that the locking tabs
secure the case.
1. Make earth ground connections to EGND terminal.
2. Connect the incoming phone line to either the 8-position jack or
the TIP and RING terminals.
3. Connect the handset phone lines to the H/S T (TIP) and H/S R
(RING) terminals.
Note:
For full line seize operation, refer to the LYNX Touch Series
Installation and Setup Guide.
4 Connect the sensors/contacts to the HWZ1 (+) and GND (-)
terminals.
5. If used, install the GSMVLP5-4G or ILP5 communications module
Refer to the Install the Communications Module section or to the
Installation Guide for the Communications Module (P/N 800-
01115 or higher).
6. Connect wires from the 300-04705/300-04605 OR 300-04063
(Canada) Power Supply to GND (-) and +9VDC (+) terminals OR
plug the Power Supply connector into the receptacle on the LYNX
Touch.
1. If you are installing the ILP5 module, use a wire cutter or knife to cut
the plastic tabs that secure the ILP5 spacer to the back case of the
LYNX Touch. If you are installing the GSMVLP5-4G module,
proceed to step 3.
2. Remove the ILP5 receptacle knockout from the left side of the
LYNX Touch back case
3 Install the Communications Module into the front case. Ensure that
the connector board is properly seated into the receptacle on the
control.
4 Secure the module with the three provided screws. If you are
installing the ILP5 module, proceed to step 5. If you are installing
the GSMVLP5-4G module, proceed to step 8
5. Insert the ILP5 receptacle and spacer into the slot on the back
case.
6. Secure the communications cable to the tie wrap point on the ILP5
with the provided tie wrap.
7. Connect the Ethernet cable to the RJ45 receptacle.
8. Enable the module, configure alarm reporting and module
supervision and register the device. Refer to the “Communications
Diagnostics” section of the LYNX Touch Installation Guide (P/N
800-10614 or higher).
1. Remove screw securing the battery retainer.
2. Remove the battery retainer.
3. Insert battery pack into back case.
4. Install battery retainer.
5. Install screw to secure the battery retainer.
6. Connect battery connector to receptacle on PC board.
7. After all wiring connections have been made, snap the front case
to the back case so it is held by the locking tabs.
8. Plug the Power Supply into a 24-hour, 110VAC unswitched outlet.
Note:
Rechargeable batteries may take up to 48-hours to fully
charge. “Battery Low” message should clear within four hours,
or by entering Test Mode.
Battery
Part Number
Battery Standby
Time (Minimum)
Low Battery Notification
LYNXRCHKIT-SC
(300-03864-1)
4-hours
Approx. 1-hour before
battery depletion
LYNXRCHKIT-SHA
(300-03866)
24-hours
At least 1-hour before
battery depletion
Ê800-110599Š
800-11059 2/12 Rev. A
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2012 Honeywell International Inc.
www.honeywell.com/security