background image

 

LYNX Touch Series Control

  

Quick Installation Guide 

This Quick Installation Guide can help you install the rechargeable LYNX Touch Series Control quickly and easily by providing the basic steps for installation using the built-in defaults.   

FOR DOCUMENTATION AND ONLINE SUPPORT: 

http://www.security.honeywell.com/hsc/resources/MyWebTech

 (see LYNX Touch Series Installation and Setup 

Guide P/N 800-10614 or higher.) A copy of the Installation and setup Guide may also be requested from Honeywell.

 

 
 

WARRANTY INFORMATION 

For the latest warranty information, please go to: 

www.honeywell.com/security/hsc/resources/wa 

 

 

1.  Install the Control 

TERMINAL
STRIP

POWER
SUPPLY
RECEPTACLE

BACK
CASE

TAMPER

SWITCH

TELEPHONE

CONNECTIONS

EDGE

CONNECTOR

WIRE ROUTING

CLIPS (3)

MOUNTING

HOOKS

(HINGES)

5100-100-078-V0

LOCKING TABS

FRONT
CASE

ROTATE

FRONT CASE

UPWARD

TO RELEASE

HOOKS

EDGE
CONNECTOR

GSMVLP5-4G/ILP5

RECEPTACLE

ILP5 RECEPTACLE

KNOCKOUT

ILP5
SPACER

BATTERY

CABLE CHANNEL

TIE WRAP

POINTS (3)

MOUNTING

HOLES (4)

TIE WRAP

POINTS (2)

INSTALL

SCREW

IN CASE
TAMPER

CASE

TAMPER

DETAIL A 

 

2.  Make Wiring Connections 

5100-100-076-V0

2K

OHM

EOLR

POWER SUPPLY

CONNECTOR

HARD

WIRED

ZONE

WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM

PREMISES

TELEPHONE

INCOMING

PHONE LINE

INCOMING

PHONE

LINE

H/S   

T

H/S   R

RING

TIP

EGND

EARTH

GROUND

HWZ1

TRIG

GND

GND

+9VDC

300-04705 or 300-04605

(300-04063 CANADA)

POWER SUPPLY

9V, 2.7A

STANDARD CAPACITY

BATTERY CONNECTORS

SUPER HIGH CAPACITY

BATTERY CONNECTOR

ZONES

POWER

PHONE

EDGE CONNECTOR
(L5100-ZWAVE)

EDGE CONNECTOR

(L5100-WiFi)

TRIGGER OUTPUT (NEG)

(3ma)

RING

TIP

RING TIP

TELCO

JACK

UL NOTE

THE MINIMUM WIRE SIZE USED FOR TELEPHONE

INSTALLATIONS MUST BE #26 GAGE

OBSERVE POLARITY WHEN

CONNECTING THE POWER

SUPPLY TO THE TERMINAL STRIP.

WARNING

TO PREVENT

RISK OF SHOCK,

DISCONNECT

TELEPHONE LINE

AT TELECOM

JACK BEFORE

SERVICING

THIS UNIT

NOTE

USE ONLY THE

300-04705/300-04605

OR 300-04063

POWER SUPPLY

PROVIDED

ALL OUTPUT CIRCUITS ARE POWER LIMITED. 

GSMVLP5-4G/ILP5

RECEPTACLE

 

 

Note: 

For the complete Summary of Connections, refer to the LYNX 
Touch Series Installation and Setup Guide P/N 800-10614 or 
higher.

 

3.  Install the Communications Module 

SIM CARD

5100-100-077-V0

ROTATED

180 

ROTATED

180 

CONNECTOR

BOARD

CONNECTOR BOARD

CONNECTOR BOARD

RECEPTACLE

LYNX TOUCH

TIE

WRAP
POINT

NOTE:

SIM CARD INSTALLED
IN GSMVLP5 ONLY

REMOVE

ILP5

SPACER

ILP5

SPACER

REMOVE

ILP5

KNOCKOUT

TIE

WRAP

(1)

LYNX TOUCH

ALTERNATE INSTALLATION

RJ45

RECEPTACLE

RJ45 RECEPTACLE

ETHERNET CABLE

GSMVLP5-4G

SCREW

(3)

ILP5

TO ILP5

 

 

 

Ensure that SIM card and the connector board are securely 
installed in the communications module before installing it 
in the LYNX Touch. 

 

4.  Make Battery Connections 

 

5000-100-01

8

-

V

1

LYNXRCHKIT-SHA

(P/N 300-03866)

OR

RETAI

N

ER

SCRE

W

RETAI

N

ER

LYNXRCHKIT-SC

(P/N 300-03864-1)

SCRE

W

 

 

1.  Release the front case from the rear case by depressing the two 

locking tabs at the top of the unit with the blade of a medium size 
screwdriver. 

2.  Separate the front and back case assemblies by rotating the front 

case so that it is perpendicular to the rear case and unsnapping 
(releasing) the two hooks (hinges) from the back case.

  

3.  Feed the wiring through the appropriate openings in the back 

case. Use tie wraps to secure the wiring to the built-in wire loops 
as needed. 

4.  Mount the back case to a sturdy wall and secure with the provided 

screws. 

5.  If required, install an additional mounting screw in the case 

tamper (see Detail A). 

6.  Attach the front and back cases by connecting the hooks on the 

front case to the attachments on back case. Once attached, the 
hooks will support the front case and allow you to make the wiring 
connections. 

7.  After all of the wiring connections have been made, snap the front 

case and back case closed and ensure that the locking tabs 
secure the case. 

1.  Make earth ground connections to EGND terminal. 
2.  Connect the incoming phone line to either the 8-position jack or 

the TIP and RING terminals. 

3.  Connect the handset phone lines to the H/S T (TIP) and H/S R 

(RING) terminals. 

Note: 

For full line seize operation, refer to the LYNX Touch Series 
Installation and Setup Guide.

 

4  Connect the sensors/contacts to the HWZ1 (+) and GND (-) 

terminals. 

5.  If used, install the GSMVLP5-4G or ILP5 communications module 

Refer to the Install the Communications Module section or to the 
Installation Guide for the Communications Module (P/N 800-
01115 or higher). 

6.  Connect wires from the 300-04705/300-04605 OR 300-04063 

(Canada) Power Supply to GND (-) and +9VDC (+) terminals OR 
plug the Power Supply connector into the receptacle on the LYNX 
Touch. 

1.  If you are installing the ILP5 module, use a wire cutter or knife to cut 

the plastic tabs that secure the ILP5 spacer to the back case of the 
LYNX Touch. If you are installing the GSMVLP5-4G module, 
proceed to step 3. 

2.  Remove the ILP5 receptacle knockout from the left side of the 

LYNX Touch back case 

3  Install the Communications Module into the front case. Ensure that 

the connector board is properly seated into the receptacle on the 
control. 

4  Secure the module with the three provided screws. If you are 

installing the ILP5 module, proceed to step 5. If you are installing 
the GSMVLP5-4G module, proceed to step 8 

5.  Insert the ILP5 receptacle and spacer into the slot on the back 

case. 

6.  Secure the communications cable to the tie wrap point on the ILP5 

with the provided tie wrap. 

7.  Connect the Ethernet cable to the RJ45 receptacle. 
8.  Enable the module, configure alarm reporting and module 

supervision and register the device. Refer to the “Communications 
Diagnostics” section of the LYNX Touch Installation Guide (P/N 
800-10614 or higher). 

1.  Remove screw securing the battery retainer. 
2.  Remove the battery retainer. 
3.  Insert battery pack into back case.  
4.  Install battery retainer. 
5.  Install screw to secure the battery retainer. 
6.  Connect battery connector to receptacle on PC board.  
7.  After all wiring connections have been made, snap the front case 

to the back case so it is held by the locking tabs.  

8.  Plug the Power Supply into a 24-hour, 110VAC unswitched outlet. 

Note:

  Rechargeable batteries may take up to 48-hours to fully 

charge. “Battery Low” message should clear within four hours, 
or by entering Test Mode. 

 

Battery  

Part Number 

Battery Standby 
Time (Minimum)

Low Battery Notification 

LYNXRCHKIT-SC 

(300-03864-1) 

4-hours 

Approx. 1-hour before 

battery depletion 

LYNXRCHKIT-SHA 

(300-03866) 

24-hours  

At least 1-hour before 

battery depletion 

 

Ê800-110599Š 

800-11059  2/12 Rev. A

 

2 Corporate Center Drive, Suite 100

P.O. Box 9040, Melville, NY 11747

Copyright © 2012 Honeywell International Inc.

www.honeywell.com/security

 