LYNXR-2 Series Installation and Setup Guide
- 17 -
Mechanics of Programming
General Programming Information
Programming options are stored in non-removable, electrically erasable, nonvolatile EEROM memory. The
system can be programmed at any time, even at the installer's premises prior to the actual installation.
Simply apply power temporarily to the Control and then program the unit as desired. There are four
programming modes:
•
Data field programming
(used for setting various system options).
•
Interactive menu mode programming
(used for programming zone information, programming
Powerline Carrier Devices, and for entering transmitter serial numbers).
•
Voice Prompt programming
(used for setting various system options).
•
Pass-Thru programming
(used for programming connected LRR/IP Communications Device).
The system can also be programmed remotely, using an IBM Personal Computer, and Compass
Downloader and modem or via capable GSM or IP communications modules. See the
Remote
Programming/Control (Downloading)
section
.
Note:
You may find it convenient to adjust the volume setting before entering the Program Mode. This will allow you to
clearly hear the feedback announcements or system beeps in the Programming Mode, of the system’s built-in
speaker. To adjust the volume, press FU [3] or [6]. Upon exiting the Program Mode, the
system will reset the volume to the default value (mid level).
Entering Program Mode
Use one of the following methods to enter Programming Mode:
1. Press both the [
✻
] and [#] keys at the same time,
within 50 seconds
after power is applied to the
Control or from exiting Programming mode,
OR
2. After power-up, enter the
Installer Code (4112) + 800
to enter
Expert Programming
mode (This
method disabled if Program mode is exited using
✻
98).
OR
enter
Installer Code (4112) + 888
to
enter
Voice Prompt Programming
mode.
If a different Installer Code has been programmed, use that code to enter the Programming mode.
3. Upon entering programming mode, the control will display “--” for up to two seconds indicating it is
communicating with the LRR/IP devices.
4. Once you have entered the Program mode, data field “20” (the first data field in the system) will be
displayed and both keypad LEDs will flash. If you have entered the Voice Prompt Programming mode.
“Pro” will be displayed.
Programming a Data Field
1. Press
[
✻
] + Field No. (for example,
✻
21), followed by the required entry.
2. When you have completely programmed a data field, the keypad will “beep” three times and then
automatically display the next data field in sequence. To go to a different field, press [
✻
] plus the
desired field number.
3. If the number of digits that will be entered in a data field is less than the maximum number of digits
available (e.g. phone number field), enter the desired data, then press [
✻
] to advance to the next data
field.
4. If a nonexistent field has been entered, the keypad will display “EE”. Simply re-enter [
✻
] plus a valid
field number.
To view a data field
without making changes:
Enter [#] +
Field No.
Data will be displayed for that field.
To delete an entry
in a field:
Enter [
✻
]
+
Field No.
+
[
✻
].
(Applies only to fields
✻
40–
✻
44,
✻
88 and
✻
94).
Summary of Contents for LYNXR-2 Series Security System
Page 4: ... 4 ...
Page 78: ...LYNXR 2 Series Installation and Setup Guide 78 Notes ...
Page 79: ...LYNXR 2 Series Installation and Setup Guide 79 Notes ...
Page 80: ...LYNXR 2 Series Installation and Setup Guide 80 Notes ...
Page 81: ...LYNXR 2 Series Installation and Setup Guide 81 Notes ...
Page 82: ...LYNXR 2 Series Installation and Setup Guide 82 Notes ...