LYNXR-2 Series Installation and Setup Guide
- 29 -
Data Field Descriptions
✻
55
Reporting Channels
0 = Telco Line (no Radio)
1 = LRR/IP(Digital Communication only) and Telco Line
3 = LRR/IP (Digital Communication only) (no Telco Line)
5 = LRR/IP (Digital Communication with AAV) (Telco Line
Connections for 2-way voice seesion only, if
applicable)
This option is used to enable/disable Central Station reporting via
the LRR/IP Communications Device (See Field *77). Upload/
download via the Internet IP module is not affected by this entry.
The option specifies the channel that the control will use when
sending reports to the Central Station (Follow Me phone, and
Pager). Select some or all channels as required.
IMPORTANT NOTE
Make sure that selected channels are physically available and
functional.
Note:
Zone 103 can not be bypassed.
Field
✻
57:
Field *57 only applies to the LYNXR-2SIA control.
✻
57
False Alarm Options
Note:
This field applies only to the LYNXR-2SIA control.
LYNXR-2SIA SELECTIONS
Value
Cancel
Alarm
Display
Auto Stay
Arming
Exit Time
Restart/
Reset
0
= Disabled Disabled Disabled
1 =
Disabled
Disabled
Enabled
2
= Disabled Enabled Disabled
3 =
Disabled
Enabled
Enabled
4 =
Enabled
Disabled
Disabled
5
= Enabled Disabled Enabled
6 =
Enabled
Enabled
Disabled
7
= Enabled Enabled Enabled
Note:
The LYNXR-2SIA control validates the data entered in this field. If the
selection is not valid the control will emit a single long beep indicating
that the selection has been rejected. The control replaces the selection
with the default value “7”, which is displayed on the keypad, and
advances to the next field.
Cancel Alarm Display
This option enables the display of aborted and cancelled alarms on the
LYNXR-2SIA keypad. “CA” will be displayed.
Notes:
1. An abort occurs if the alarm panel is disarmed before it dials the
alarm report to the central station.
2. A cancel occurs if the alarm panel is disarmed after the alarm is
reported.
3. Zone types 5, 6 and 7 (panic zone types) and 24 (silent burglary)
cannot be cancelled.
Auto Stay Arming
If this feature is enabled and the control panel has been armed “Armed
Away” at the LYNX keypad or RF keypad, the system will switch to the
“Armed Stay” mode if the Exit Time has expired and no exit has been made.
Exit Time Restart-Exit Delay Restart/Reset
This option allows the systems to restart the exit delay time
after arming in STAY mode by entering the User Code and pressing the
STAY key (if quick arming is disabled) or by pressing the STAY key (if
quick arming is enabled). This option also enables automatic exit delay
reset, which resets exit delay if the entry/exit door is re-opened and closed
before exit delay time expires after arming.
Notes:
1. This avoids the need to disarm and then re-arm the system after
allowing someone to enter or exit.
2. Automatic Exit Delay Reset occurs only once during an armed
period.
✻
58
RF Jam Detection
0 = no jam detection
1 = RF jam detection with event logging, but no central
station report
2 = RF jam detection with event logging and with central
station report (if trouble/restore report is enabled in
fields
✻
60,
✻
71)
For Event Logging, Option 2 must be selected.
If the control detects an RF Jam condition, a “FAULT” message appears for
zone 90. The Contact ID® code for RF Jam is 344.
SYSTEM STATUS AND RESTORE REPORT CODES PROGRAMMING (
✻
59 –
✻
76, &
✻
89)
Program Report Codes using the interactive *56 Enhanced Zone Programming Mode, or codes can be entered in data
fields *59
-*
76 and *89. Use the following guidelines when programming report codes. The actual report code digits
entered depend upon the particular installation, and should be in agreement with you and the central station office
receiving the signals.
Field *59 is used to program different features in the LYNXR-2 and LYNXR-2SIA controls. Please be sure
that you use the correct field for the control being installed.
With a 3+1 or 4+1 Standard Format:
Enter a code in the first box: 1–9, A, B, C, D, E, or F. Enter "#+10" for A
(reports a “0” on some receivers), "#+11" for B, "#+12" for C, "#+13" for D, "#+14" for E, "#+15" for F. Entering "0" in the
first
box will disable a report. Entering "0" in the second box results in automatic advance to the next field.
Summary of Contents for LYNXR-2 Series Security System
Page 4: ... 4 ...
Page 78: ...LYNXR 2 Series Installation and Setup Guide 78 Notes ...
Page 79: ...LYNXR 2 Series Installation and Setup Guide 79 Notes ...
Page 80: ...LYNXR 2 Series Installation and Setup Guide 80 Notes ...
Page 81: ...LYNXR 2 Series Installation and Setup Guide 81 Notes ...
Page 82: ...LYNXR 2 Series Installation and Setup Guide 82 Notes ...