Data Field Descriptions
With an Expanded or 4+2 Format:
Enter codes in
both
boxes (1st and 2nd digits) for 1–9, or A–F, as described above.
Entering "0" in the first box will disable a report. Entering "0" in the second box will eliminate the expanded message for
that report.
With ADEMCO Contact ID® Reporting:
Enter a digit in the first box to enable the zone to report. Use a different
digit for each zone until you have used up available digits. If the number of zones exceeds the number of available
digits, begin with digit 1 again. This is an "enabling" code only and is not the actual code sent to the central station
office. Entries in the second boxes will be ignored. For system status (non-alarm) codes, enter a “1” in the first box for all
the system conditions you want to send to the central station. A "0" in the first box disables the report.
For the LYNXR-2SIA control the *59 Exit Error Report Code and *68 Cancel Report Code options are always enabled. A report
code can be entered if reporting formats other than Contact ID
®
are used.
SYSTEM STATUS REPORT CODES
(
✻
59–
✻
68)
✻
59
Exit Error Report Code
(See notes above)
LYNXR-2SIA ONLY
Always enabled, a report code can be entered if reporting
formats other than Contact ID
®
are used.
If the system is armed and an entry/exit or interior zone is still open after
the exit delay time has expired, an alarm will sound at the keypad and
external sounder. If the system is disarmed before the end of the entry
delay that immediately follows, the alarm sounding will stop and no
message will be sent to the central station. The keypad will display “CA
(CANCELED ALARM).”
If the system is not disarmed before the end of the entry delay mentioned
above, and an entry/exit or interior zone is still open, an “exit alarm”
message will be sent to the central station if an Exit Error report code is
selected in this field. The keypad will display “EA (EXIT ALARM),” and the
alarm sounding will continue until the system is disarmed (or timeout
occurs).
An Exit Alarm condition will also result if a fault occurs in an exit or
interior zone within 2 minutes following the end of the exit delay, and an
“Exit Alarm” message will be sent to the central station.
If Contact ID® format has been programmed, the message will contain the
zone number and error code 374 (Trouble–Exit Error). If 4+2 format is
used, the digit entered in this field will be sent followed by the second digit
of the programmed alarm code for that zone. If 3+1 or 4+1 format is used,
only the digit entered in this field will be sent. This message will go to the
primary phone no. Under any of these conditions, no restore message will
be sent.
If “0” is entered in this field, no special message will be sent, only the
regular alarm and alarm restore code for the zone.
LYNXR-2SIA ONLY
If the system is armed and an entry/exit or interior zone is still open after
the exit delay time has expired, an alarm will sound at the keypad and
external sounder (the keypad will also display “EA”) , and the entry delay
begins. If the system is disarmed before the end of the entry delay that
immediately follows, the alarm sounding will stop and no message will be
sent to the central station. The keypad will display “CA “(CANCELED
ALARM) if the cancel display option was enabled in field
✻
57.
If the system is not disarmed before the end of the entry delay mentioned
above, and an entry/exit or interior zone is still open, an “Exit Alarm”
message and a “Zone Alarm” message will be sent to the central station.
The keypad will display “EA (EXIT ALARM),” and the alarm sounding will
continue until the system is disarmed (or timeout occurs).
If Contact ID® format has been programmed, the message will contain the
zone number and error code 374 (Alarm–Exit Error).
Note:
The LYNXR-2SIA control validates the data entered in this field. If the
selection is not valid the control will emit a single long beep indicating
that the selection has been rejected. The control replaces the selection
with the default value “1”, which is displayed on the keypad, and
advances to the next field.
✻
60
Trouble Report Code
(See notes above)
This will be sent if a zone goes into trouble.
✻
61
Bypass Report Code
(See notes above)
This will be sent when a zone is manually bypassed.
Summary of Contents for LYNXR-2 Series Security System
Page 4: ... 4 ...
Page 78: ...LYNXR 2 Series Installation and Setup Guide 78 Notes ...
Page 79: ...LYNXR 2 Series Installation and Setup Guide 79 Notes ...
Page 80: ...LYNXR 2 Series Installation and Setup Guide 80 Notes ...
Page 81: ...LYNXR 2 Series Installation and Setup Guide 81 Notes ...
Page 82: ...LYNXR 2 Series Installation and Setup Guide 82 Notes ...