80 Device Programming Menu Mode
The following explains these prompts in detail. The left two columns identify the prompts and list the
available entries. The right-most column provides a further explanation of the entries.
Note:
Entering a number other than one specified will give unpredictable results.
ZT16 is only available on the LYNXR-2SIA version of the control panel.
80
Powerline Carrier Device
Programming
0 = exit mode
1 = enter mode
Entering “0” exits mode, upon which this prompt blinks, indicating that the mode is
inactive.
Entering “1” advances to the next prompt below.
A
01
Device Number
01-08 = X10 device number to be
programmed
09-16 = Multi-mode (e-mail) event triggers
[
✻
] = continue
00 = exit Device Programming mode
Enter device numbers as 2-digit entries.
b aa
Device Action
0 = No response
1 = Close for 2 seconds
2 = Close and Stay Closed
3 = Continuous Pulse on & off (1 sec ON, 1
sec OFF)
[
✻
] = continue
[#] = return to previous prompt
Enter the 1-digit action (0-3) for the device being programmed (current action is
displayed).
Notes:
(1) If “3” is entered (pulse), only up to 3 different devices can be pulsed if one of
the devices is a siren/horn (X10 Powerhouse Security model SH10A). In
addition, the siren/horn cannot be manually activated using the lights
on/lights off keypad commands.
(2) If using an X10 Powerhouse Security SH10A siren, you must:
•
use device action “3.”
•
change the device action default to “3” (if using default table 2 or 4)
.
C
et
Start Event Type
0 = Not used
1 = Alarm
2 = Fault
3 = Trouble
[
✻
] = continue
[#] = return to previous prompt
Enter the 1-digit event type (0-3) to activate the device being programmed. A zone list
must be used in conjunction with an event. If a zone type/system operation is to be
used instead of an event, enter “0”.
d zl
Start Zone List
1-3 = zone list number (to be programmed in
field
✱
81)
0 = zone list not used for this device
[
✻
] = continue
[#] = return to previous prompt
If a zone list will be used to start the device action, enter the zone list number at this
prompt.
Summary of Contents for LYNXR-2 Series Security System
Page 4: ... 4 ...
Page 78: ...LYNXR 2 Series Installation and Setup Guide 78 Notes ...
Page 79: ...LYNXR 2 Series Installation and Setup Guide 79 Notes ...
Page 80: ...LYNXR 2 Series Installation and Setup Guide 80 Notes ...
Page 81: ...LYNXR 2 Series Installation and Setup Guide 81 Notes ...
Page 82: ...LYNXR 2 Series Installation and Setup Guide 82 Notes ...