LYNXR-2 Series Installation and Setup Guide
- 44 -
✻
80 Device Programming Menu Mode
E
zt
Start Zone Type
01-58 = zone type to start this device action
(select only those that are applicable
00 = zone type not used for this device
[
✻
] = continue
[#] = return to previous prompt
If a zone type or system operation will be used to start the device action, enter the
appropriate 2-digit code for the device being programmed (see table that follows).
Choices for zone types
00 = Not Used
07 = 24 Hr Audible
01 = Entry/Exit #1
08 = 24 Hr Aux
02 = Entry/Exit #2
09 = Fire without verification
03 = Perimeter
10 = Interior w/Delay
04 = Interior Follower
14 = Carbon Monoxide
05 = Trouble Day/Alarm Night
16 = Fire with verification
06 = 24 Hr Silent
24 = Silent Burglary
Choices for system operation
20 = Arming–Stay
38 = Chime
21 = Arming–Away
52 = Kissoff
22 = Disarm. (Code + OFF)
39 = Any Fire Alarm
31 = End of Exit Time
40 = Bypassing
32 = Start of Entry Time
42 = System Battery Low
33 = Any Alarm (except ZT 08,
09, 14 or 16)
43 = Communications Failure
36 = At Bell Timeout**
58 = Duress
** Or at Disarming (which ever occurs earlier)
SIA
ZT 16 must be used in SIA fire applications.
F
zl
Stop Zone List
1-3 = zone list to stop this device action
0 = zone list not used
[
✻
] = continue
[#] = return to previous prompt
If a zone list will be used to STOP, or restore, the device action, enter the zone list
number 1, 2, or 3 (to be programmed in
✻
81 mode). If not used, enter “0”.
1A
zt
Stop Zone Type
01-58 = zone type to stop this device action
(select only those that are applicable
00 = zone type not used for this device
[
✻
] = continue
[#] = return to previous prompt
If a zone type or system operation will be used to STOP the device action, enter the
appropriate 2-digit code (see the "ZT" choices listed above). If not, enter 00. The
display then returns to the DEVICE NUMBER prompt (A) so that you can enter the
next device number to be programmed, or enter [0][0] to end device programming
Summary of Contents for LYNXR-2 Series Security System
Page 4: ... 4 ...
Page 78: ...LYNXR 2 Series Installation and Setup Guide 78 Notes ...
Page 79: ...LYNXR 2 Series Installation and Setup Guide 79 Notes ...
Page 80: ...LYNXR 2 Series Installation and Setup Guide 80 Notes ...
Page 81: ...LYNXR 2 Series Installation and Setup Guide 81 Notes ...
Page 82: ...LYNXR 2 Series Installation and Setup Guide 82 Notes ...