Page 2: ...may be attached to your security system s control or other communicating bus if Honeywell has not approved such device for use with your security system Use of any such unauthorized device may cause damage or compromise the performance of your security system and affect the validity of your Honeywell limited warranty When you purchase devices that have been manufactured or approved by Honeywell yo...

Page 3: ...sarming the System 20 User Code Error Touchpad Lockout 20 Bypassing Protection Zones 20 Entry and Exit Delays 21 Emergency Alarms 22 Chimes Voice Annunciations 23 Audio Alarm Verification Two Way Voice 24 AUTOMATION Z WAVE AND OTHER DEVICES 25 Working with Z Wave Devices 25 Adding Z Wave Devices Include Devices 26 Deleting Z Wave Devices Exclude Devices 28 Editing Z Wave Device Names 29 Advanced T...

Page 4: ...ME GATEWAY APP SYMBOLS 51 EVENT LOG CODES 52 GLOSSARY 55 FIRE CO ALARM SYSTEM 56 In Case of Fire 56 In Case of Carbon Monoxide Alarm 56 Silencing a Fire Carbon Monoxide Alarm 56 NATIONAL FIRE PROTECTION ASSOCIATION SMOKE DETECTOR RECOMMENDATIONS 57 Emergency Evacuation 58 REGULATORY AGENCY STATEMENTS 59 WIRELESS KEYS 60 Key Assignments 60 SiXFOB Wireless Key Status Indications 60 YOUR SYSTEM INFOR...

Page 5: ...remise s Wi Fi router Ethernet cable or Wi Fi The Total Connect App requires internet or cellular connection for remote access to the Gateway Note for Android Mobile Device Users Before using the MyHome Gateway App disable Power Saving mode on your device Failure to do so may cause the app to lose connection to the Gateway if the mobile device enters power save mode About This Guide Throughout the...

Page 6: ...ser code Disarm system silence alarms and enter your user code repeat to silence alarms alerts Emergency Panic Not available from the MyHome Gateway App Use the Gateway Touchpad Emergency options or if programmed to do so use your wireless key key fob to signal an emergency Video Press on the Home screen to view and configure Wi Fi cameras Control Panel Settings Press Settings on the Home screen G...

Page 7: ...on Master User Functions Press Security then Tools and enter your Master User code Add delete or modify user codes Users View a list of System Events Events System tests Advanced and select Walk Test or Comm Test View a list of mobile smart devices paired to your Gateway Paired Devices Network Wi Fi Configuration Network Config ...

Page 8: ...ystem The system also features Chime mode which can alert you to the opening of protected doors and windows while the system is disarmed Security User Codes A user code is required when arming or disarming and for some other functions When the system is installed you are asked to choose a personal 4 digit security code known as the Master User code Other users can be added typically with less cont...

Page 9: ...e exit delay ends The delay period is set by your installer Exit Time Restart Exit Delay Restart Reset If you leave the premises and enter again before the exit delay has expired the exit delay restarts giving you more time to leave without causing an alarm With 10 seconds left to exit the Gateway begins beeping quickly indicating that an alarm will occur if you don t exit or disarm the system imm...

Page 10: ...10 ...

Page 11: ...our Gateway with the MyHome Gateway App section in this User Reference Guide to operate your system with the MyHome Gateway App Gateway Menu Modes The Gateway provides a Menu Mode with options to add and delete smart devices from your system or change the system Wi Fi network Access the Menu Mode when the System is disarmed and the numbers are off Enter the Master user code then the two digit code...

Page 12: ...Red blinking slowly Entry delay countdown started enter your user code to disarm the system Red blinking rapidly System is in Alarm If programmed to do so two way Voice Communication may be active when the system is in Alarm See your installer to program this feature White steady System is waiting for a user code See the Emergency section for information on silent alarms System Alert If the system...

Page 13: ... a code in Away mode or Home mode or For 3 seconds Disarm the system and enter your user code Switching Arming Modes You can easily switch between arming modes without having to first disarm the system When the system is armed or while arming or disarming simply press the desired arming option and enter your user code This feature is available only from the Gateway Touchpad or a Wireless Key Auto ...

Page 14: ...ID OPTGW_ is listed on a label on the bottom of the Gateway b When prompted enter Gateway s 8 Digit case sensitive WPA2 Password The password is also on the SSID label 3 Launch the MyHome Gateway App on a device 4 Enter your Master user code then 2 1 on the Gateway Touchpad 5 The App displays a six digit Pairing key number Enter that number on the Gateway Touchpad and the system announces when Enr...

Page 15: ...ually operate your Z Wave devices and select the device Add or delete Z Wave Devices then and See the Automation section for details TC Video View and configure system cameras manage video recovery functions See Video section for details Smart Scenes View and run automation scenes to operate your system for convenience comfort energy savings and security and enter your Master User Code See the Sma...

Page 16: ...s The Master User code is required See Users and Security Codes for details Events View system event logs See Events Advanced Access software upgrades tests and user maintenance functions Includes features found in the Maintenance and System Settings sections Paired Devices Manage smart devices paired to your Gateway See Paired Devices Network Config Configure Wi Fi connection to the Gateway See W...

Page 17: ...ound alarms The MyHome Gateway App displays the system arming status top and center of the screen Ready to Arm the system is ready to be armed Not Ready To Arm Fault one or more zones are faulted The system cannot be armed until all zone faults are fixed or bypassed Armed Home Away Custom etc the system is armed and arming mode description Arming the System Before arming your system all protected ...

Page 18: ...mmediately if an exterior door is opened Quick Arm Used to arm the system in any mode without entering a user code if programmed NOTE A user code is always needed to disarm the system Auto Home If you arm the system in the Away mode but no one exits the alarm system automatically changes to the Home mode This helps to prevent unwanted alarms when someone remains on the premises Disarm the system a...

Page 19: ...the door Bypassed zones are left unprotected NOTE The next time Arm Custom is used the same zones that were previously selected are highlighted on the zone list screen If desired select different zones for custom arming Instant Mode Security Arm Custom In Instant mode an alarm occurs immediately when a protected Entry Exit is opened There is no Entry delay during which a code can be entered to dis...

Page 20: ...t additional user code entries for 15 minutes lockout period Bypassing Protection Zones Any zones with faults must be cleared before arming the system Bypass allows arming the system while intentionally leaving selected zones unprotected Bypassed zones will not trigger an alarm To Bypass zones 1 Before arming the system press Zones on the Security menu A list of your system s zones appears Faulted...

Page 21: ... by the installer Exit delay can be restarted once Exit Alarm This option helps minimize false alarms sent to the monitoring company Exit Alarm is always enabled Exit delay begins whenever the system is armed If an exterior door or protected interior zone is faulted during the exit delay and remains faulted when the exit delay ends an exit alarm occurs and an entry delay countdown begins If the sy...

Page 22: ...o audible alarms or display on either the Gateway Touchpad or MyHome Gateway screen Requires connection to a monitoring company Audible emergency audible alarm Sends an emergency message to the monitoring company if connected A loud steady tone sounds at the Gateway and external sounders if connected and an alarm appears on the MyHome Gateway App screen Personal emergency or Aux alarm Sends an eme...

Page 23: ...NT The Chime feature is intended for convenience and is not intended for life safety purposes or pool alarm and does not meet the requirements of UL 2017 Volume Mute Home Settings Gateway can be set to give audible notifications when a protected zone opens while the system is disarmed On the Settings screen 1 Select CHIME and PANEL VOICE to enable chime sounds and voice annunciations De select PAN...

Page 24: ...tem announcements are disabled when this feature is active Fire and CO alarms prevent Audio Alarm Verification from operating New Fire or CO alarms terminate Audio Alarm Verification operation Burglar alarms occurring during Audio Alarm Verification operation do not interrupt operation and are reported immediately after operation concludes Audio Alarm Verification modes are controlled by the centr...

Page 25: ...roughout the home This product can be included and operated in any Z Wave network with other Z Wave certified devices from other manufacturers and or other applications All non battery operated nodes within the network act as repeaters regardless of vendor to increase the network reliability NOTES Z Wave Grouping Identifier of Gateway is 1 and used for the Lifeline association The maximum number o...

Page 26: ... device can be Included successfully 1 On the Z Wave Device Management screen press the Down arrow 2 Press Tools 3 Options appear including Include Devices Exclude Devices and Advanced Tools View Failed Devices and Replace Failed Devices may also appear 4 Select Include Devices After the Gateway enters Inclusion mode the screen displays Ready to Include Device Press the function button on the devi...

Page 27: ... your system Refer to the device s instructions for more information about installation IMPORTANT Honeywell is not responsible for property damages due to improper setting of thermostat modes NOTES Some thermostats may not update temperature status displayed on the MyHome Gateway App When using Z Wave thermostat control on the Gateway make sure the thermostat s scheduling feature is disabled on th...

Page 28: ...ed thermostat Threshold Monitoring Enable Disable Threshold Monitoring Feature if available Saving Off Saving On Enables disables the thermostat s Energy Saving Schedule Function EDIT Used to edit the thermostat s name BACK Used to return to Thermostats screen Thermostat Energy Saving Mode 1 On the Z Wave Device Management screen select Thermostats 2 Select the desired thermostat from the displaye...

Page 29: ...mation Primary or Secondary Z Wave Library Rev Home ID device type device ID node number manufacturer Secured or Non Secured Factory Default Controller Press to delete all Z Wave nodes in the Gateway and reset the Gateway s Home ID When prompted press Yes to confirm Important Defaulting the Controller does not delete Exclude individual Z Wave devices Therefore each device must be Excluded before b...

Page 30: ...l on the Z Wave Device Management screen or the symbol appears in gray on the Home screen To view Failed Devices 1 On the Z Wave Device Management screen select View Failed Devices OR press the Down arrow Tools and then View Failed Devices 2 The device s information is displayed If multiple devices are listed use the up and down arrows at right to view the entire list NOTE When troubleshooting a f...

Page 31: ...hat cannot detect an object and stop and reverse the door does not meet current U S federal safety standards Your garage door opener also must signal before unattended door operation For more information please consult your garage door opener manual NOTE Press Switches on the Z Wave Device Management menu to configure new Z Wave binary garage door openers Ask your security professional for more in...

Page 32: ... since the metal box blocks a large part of the RF signal Additional Z Wave Information Gateway can control up to 72 Z Wave devices The system supports a maximum of 232 nodes Note that a node is created every time a device is Included even if the device is being re added to the system after being Excluded This can cause the number of nodes in the system to exceed the number of actual devices If th...

Page 33: ... Wireless Siren Strobe Alarm Kwikset Smartcode Deadbolt Lock Water Valve Thermostats FortrezZ WV 01 Wireless Z Wave Water Valve Honeywell Z Wave Thermostat ZWSTAT Garage Door Wayne Dalton Z Wave Thermostat Linear GDZ 004 Garage Door Module Trane Z Wave Thermostat Window Shades Residential Control Systems Thermostat Model TZ45 Somfy ILT Series Intermatic InTouch Thermostat Model CA8900 Somfy Z Wave...

Page 34: ...d in pairs For example a Smart Scene might be set to operate multiple devices turning on lights and opening blinds or shades A second Smart Scene could be used to return these devices to their off or closed states NOTES As many as 100 Smart Scenes can be created You can modify Edit manually start Run and review Show Smart Scenes prior to operation Scheduled and Triggered Smart Scenes can be paused...

Page 35: ... scenes are labeled as When you manually run this scene or When you click it in Total Connect Creating any Smart Scene involves these settings Name The type of trigger that initiates the Smart Scene The type of user who can manually run the Smart Scene The resulting action s that take place when the triggering events or conditions occur NOTE Creating a Smart Scene should begin with giving it a Nam...

Page 36: ...pend on the system s connection to the internet or cellular phone network Ask your installer for more information d Set the days of the week for the Smart Scene to take place e Press Save The schedule settings are displayed f Press New Action to define the response when the scheduled time occurs see Step 8 g Press to return to the Smart Scenes menu 8 Select Triggered Action These options appear Sm...

Page 37: ... to a Fault Trouble or Alarm in a particular zone or changes to connected devices A note about triggering events Any change in the state of a security system zone is known as a Fault Faults can include Trouble and Alarm conditions Trouble can include low battery or loss of communication with the device Alarm conditions include zone faults while the system is armed and fire CO detectors Fault Troub...

Page 38: ...trols allow you to pause preview execute and review Smart Scenes from the MyHome Gateway App NOTE You can use the Hold Run and Show functions from the MyHome Gateway App even when set up with Total Connect remote services Hold Hold allows Scheduled and Triggered Smart Scenes to be temporarily suspended A Scheduled Smart Scene can be put on Hold before programmed operations take place 1 Select a Sc...

Page 39: ... to return to the list view With multiple cameras displayed you can select one to work with by tapping its video window 4 Viewing a single camera displays its details which vary with the camera selected For all compatible cameras you can Name the camera Select Name above the video display or Edit at right Press Save on the on screen keyboard Press to show the camera full screen Press to return to ...

Page 40: ...uest Visitors and others who are authorized to arm disarm the system only at certain times or on a temporary basis Examples babysitters cleaning people etc The Guest s user code can be used to arm the system but cannot disarm it unless the system was armed using the Guest code The Guest s user number is 47 Duress Code IMPORTANT The Duress function requires connection to an alarm monitoring service...

Page 41: ...nd then Edit c Set Change Duress Code Press Duress and then Edit Enter a 4 digit code 5 Save after making settings The list of user codes reappears 6 Press to return to the Tools menu Changing Security Codes or the Duress Code The Master User can change other users names and security codes as well as delete users from the system 1 Access the Users screen as shown above 2 Select one of the listed u...

Page 42: ...e 1 Press User Code A keypad appears 2 Press Clear if you are changing an existing code 3 Enter a four digit code 4 Press Done User details appear 5 Save The list of users appears Users and Z Wave Lock Control NOTE This option appears only if Z Wave devices are connected Each user can be given the ability to disarm the system by entering their code to open a Z Wave lock When creating or editing a ...

Page 43: ...ints A list of available networks is displayed Use the up and down arrows to scroll through the list Press to return to the previous screen 3 Select the desired network and press Edit The network information is displayed 4 If a password is required press Key enter the password press DONE and Save 5 Press JOIN and a confirmation message appears 6 Press YES and the system announces when connected to...

Page 44: ...cessfully added to the network Press OK 5 Change network settings on all mobile devices that have the MyHome Gateway App to the same network as the Gateway If the WPS connection does not succeed the Gateway announces a failure to connect message and the system reverts to the previous network connection Try the process again Software Updates Home Security Tools Advanced Gateway Software updates for...

Page 45: ...y are displayed Viewing Events 1 On the Tools menu press Events The MyHome Gateway App Events screen lists all events sorted chronologically 2 Press All to select different sorting options Alarm Trouble Bypass Open or Close or Non Security 3 Select All on the list to return to the view of all events Paired Devices Home Security Tools Paired Devices This menu displays the name of mobile devices con...

Page 46: ...e MyHome Gateway App screen Notifications of problem zones clear when the door or window is closed Motion Sensors Walk in front of each sensor and listen for three beeps and or voice descriptors The device s identification should appear on the display when it is activated The display clears when no motion is detected NOTE If wireless motion detectors are in use there is a 3 minute delay between ac...

Page 47: ...essful the MyHome Gateway App screen displays Service OK or ACK Received Details of the test may be shown Test Ethernet Checks internet connectivity without sending test messages Send Any Sends test messages via all available connections Send Cellular Message Sends test messages via cellular network Send Ethernet Message Sends test messages via internet Finish by pressing to run a different test o...

Page 48: ...ery IMPORTANT Replace the battery pack when the Security menu displays Low Battery with no zone number specified Use only batteries recommended by the installer or the manufacturer Disarm the system before changing the Gateway s battery pack Remember that you must enter the Master User code for access to the Tools menu Gateway 1 On the MyHome Gateway App navigate to the Advanced menu and select In...

Page 49: ...eattach the desk stand 11 On the MyHome Gateway App screen press OK on the battery installation procedure screen The system confirms Battery successfully installed 12 Press OK The system returns to the Advanced menu 13 Press to return to the previous screen s Sensors IMPORTANT The Gateway beeps every 40 45 seconds when a sensor reports a low battery A sensor with a low battery will continue to ope...

Page 50: ... code 4 Select Advanced then Install Cellular Module Follow the on screen instructions for changing the module 5 Squeeze inward on the corners of the top cover and remove the top cover as shown 6 Use the Communication Module pull tab to remove the old module 7 Insert the replacement Communication module as shown 8 Press OK on the MyHome Gateway App screen and the system confirms installation 9 Pre...

Page 51: ...i signal strength Window Open Arm Home Wi Fi Loss Glass Break Arm Custom AC Power Loss Fire or Heat Sensor Arm Night Home Low Battery Flood Sensor Disarm No Battery Features Various Icons may appear in red or orange to indicate device status Problems involving Z Wave devices are indicated by the Automation icon appearing in gray on the Home screen Tools Network Wi Fi Configuration Locks Users Auto...

Page 52: ...efinition Event Log Display 110 Alarm Fire Fire 121 Alarm Duress Duress 122 Alarm Silent Silent 123 Alarm Audible Audible 131 Alarm Perimeter Perimeter 132 Alarm Interior Interior 134 Alarm Entry Exit Entry Exit 135 Alarm Day Night Day Night 137 Alarm Tamper Tamper 145 Expansion Module Tamper Expansion Module Tamper 146 Silent Burglary Silent Burglary 150 24 Hour Non Burglary 24 Hour Non Burglary ...

Page 53: ...ident Monitor Zone Response 760 Resident Response Zone Response Resident Response Zone Response 761 General Monitor Zone Response General Monitor Zone Response 762 General Response Zone Response General Response Zone Response 1401 Local Alarm Local Alarm 3000 Binary Switch Off Switch Off Z Wave Device 3001 Binary Switch On Switch On Z Wave Device 3100 Multi Level Switch Change Level Off Multilevel...

Page 54: ...ostat Hold Thermostat Hold 3411 Thermostat No Scheduling Thermostat No Scheduling 3412 Thermostat Normal Mode Thermostat Normal Mode 3500 Low Battery Low Battery Z Wave Device 3501 Low Battery Restore Low Battery Restore Z Wave Device 5000 Critical Panel Firmware Update Downloaded Critical Panel Update Downloaded If your Central Monitoring Station receives a Comm Fail message E316 your system has ...

Page 55: ... to be opened for a set time period This feature is used for checking the mailbox retrieving the newspaper etc Zone Specific areas of protection in your home Sensing devices are assigned to these numbered Zones with designations such as front door kitchen window etc Zone numbers appear on the display when an alarm or fault occurs Z Wave Controller The primary controller is the main device used to ...

Page 56: ...y your local Fire Department immediately 4 If no flames or smoke are apparent investigate the cause of the alarm The zone number of the zone s in an alarm condition appears on the MyHome Gateway screen In Case of Carbon Monoxide Alarm 1 If a high level of carbon monoxide is detected you should evacuate all occupants from the premises and immediately move to a location where fresh air is available ...

Page 57: ...ction equipment in all rooms and areas of the household The equipment should be installed as follows A smoke detector installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfinished attics In addition the NFPA recommends that you install heat or smoke dete...

Page 58: ...rs stairs and rooftops that can be used to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes in every room 4 Assure that all bedroom doors are shut while you are asleep This will prevent deadly smoke from entering while you escape 5 Try the door If the door is hot check your alternate escape route If the door is cool open it ca...

Page 59: ...ustrie Canada Son fonctionnement est soumis aux conditions suivantes 1 Cet appareil ne doit pas causer d interférences nuisibles 2 Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception indésirable RF EXPOSURE WARNING The antenna s used for this device must be installed to provide a separation distance of at least 7 8 inches 20 cm from all persons and...

Page 60: ...__ 5800 Series wireless key Button 1 ___________________ Button 2 ___________________ Button 3 ___________________ Button 4 ___________________ Button 8 ___________________ press and hold BOTH buttons to activate SiX Series wireless key SiXFOB Wireless Key Status Indications Press and release any key for system status Status is indicated by the LEDs at the top of the key fob Green LEDs Red LEDs So...

Page 61: ...mode enabled Yes No Audio Alarm Verification enabled Yes No Two Way Voice FIRE Yes No MEDICAL Yes No POLICE Yes No Silent Alarm Reporting Delay __________ SYSTEM USERS Keep track of authorized system users in the chart below This record should be kept secure by the Master User User User Code Comment Description 02 preset Master User Can add and modify Users Can add modify edit and run all Smart Sc...

Page 62: ...62 ZONES Zone Number Location and Description ...

Page 63: ...63 SMART SCENES Smart Scene Name Description Z WAVE DEVICES Type Name Location ...

Page 64: ...64 Notes ...

Page 65: ...65 Notes ...

Page 66: ...66 Notes ...

Page 67: ...67 Notes ...

Page 68: ...s 16 45 52 Exit Alarms 9 Exit Delay 9 21 37 61 False Alarm Prevention 9 Gateway Menu Modes 11 Gateway Touchpad 5 6 8 11 12 13 14 22 43 56 Guest 40 41 Instant Arm 18 Key Fob 44 Keypad Lockout 8 Maintenance 48 Master User 7 40 Master User Code 46 Memory of Alarm 8 23 MyHome Gateway App 15 Network Config 16 Network Configuration 14 43 Paired Devices 16 45 Quick Arm 18 Quick Exit 9 55 Reboot 47 Securi...

Page 69: ...69 ...

Page 70: ...al Sounding Device Police Dept Fire Dept Central Station Name _________________________________________________________________________ Address Phone C POWERED BY A C with Rechargeable Power Supply D TESTING Quarterly Monthly Weekly Other E SMOKE DETECTOR LOCATIONS Furnace Room Kitchen Bedrooms Attic Basement Living Room Dining Room Hall F BURGLARY DETECTING DEVICE LOCATIONS Front Door Basement Do...

Page 71: ...otion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual Passive Infrared Detectors do not provide volumetric area protection They do create multiple beams of protection and intrusion can only be detected in unobstructed areas covered by those beams They cannot detect motion or intrusion that takes place behind walls ceilings floors closed doo...

Page 72: ...ATING IN ANY WAY TO THE PRODUCT AND OR FOR BREACH OF THIS OR ANY OTHER WARRANTY OR CONDITION EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY SELLER S OWN NEGLIGENCE OR FAULT AND EVEN IF SELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSSES OR DAMAGES Any product description whether in writing or made orally by Seller or Seller s agents...