Lyric Gateway Installation and Reference Guide
- 12 -
Wireless Zones
Wireless Zones
Wireless Zones
Wireless Zones
General Information
General Information
General Information
General Information
Zones
Zones
Zones
Zones
The Lyric Gateway supports up to 64 total wireless protection zones using 5800 and SiX™ Series transmitters,
and wireless keys.
Range
Range
Range
Range
The built-in RF receiver can detect signals from wireless transmitters within a nominal range of 200 feet.
T
T
T
Transmitters
ransmitters
ransmitters
ransmitters
5800 and SiX™ Series transmitters have built-in serial numbers that must be entered into the system via
AlarmNet 360
TM
. Each transmitter's zone number is also programmed into the system in the “Zones”
programming section. Some transmitters, such as the 5816 can support more than one "zone" (referred to as
loops or inputs). On the 5816, for example, the wire connection terminal block is loop 1; the reed contact is loop
2. Each loop must be assigned a different zone number.
For 5800 Series wireless keys such as the 5804E, 5834-4 and 5878, you must assign a unique zone number to
each individual button used on the transmitter. Each button on the transmitter also has a pre-designated loop
or input number, which is automatically displayed.
ETL
ETL
ETL
ETL
The 5816
The 5816
The 5816
The 5816 Transmitters do n
Transmitters do n
Transmitters do n
Transmitters do not have EOL
ot have EOL
ot have EOL
ot have EOL supervision of their loop wiring
supervision of their loop wiring
supervision of their loop wiring
supervision of their loop wiring, which
, which
, which
, which m
m
m
must
ust
ust
ust not exceed 3
not exceed 3
not exceed 3
not exceed 3
feet.
feet.
feet.
feet.
The
The
The
The 5800PIR
5800PIR
5800PIR
5800PIR----OD,
OD,
OD,
OD, 5800SS1,
5800SS1,
5800SS1,
5800SS1, 5804E,
5804E,
5804E,
5804E, 5814,
5814,
5814,
5814, 5821, 5877
5821, 5877
5821, 5877
5821, 5877 and
and
and
and 5878
5878
5878
5878 wireless transmitters
wireless transmitters
wireless transmitters
wireless transmitters have not been
have not been
have not been
have not been
evaluated by
evaluated by
evaluated by
evaluated by ETL
ETL
ETL
ETL....
Transmitter Supervision
Transmitter Supervision
Transmitter Supervision
Transmitter Supervision
With the exception of some transmitters/keypads that may be carried off-premises (5804E, 5834-4 and
SiXFOB), each transmitter is supervised by a check-in signal that is sent to the receiver at 70–90 minute
intervals. If at least one check-in is not received from each supervised transmitter within a 12-hour period, the
"missing" transmitter zone number(s) and "Supervision" will be displayed. The supervision for a particular
transmitter in the system that may also be carried off the premises may be turned off by entering it as an
“Unsupervised” type. For additional information, refer to the “Zones” programming section in the Lyric
Gateway Quick Installation Guide (p/n 800-21668). 5800 and SiX™ Series transmitters have built-in tamper
protection and will annunciate as a fault condition if covers are removed. In Canada the RF supervision period
is 3-hours for Fire zones and 12 hours for all other zone types.
Tr
Tr
Tr
Transmitter Input Types
ansmitter Input Types
ansmitter Input Types
ansmitter Input Types
Each transmitter has one or more unique factory-assigned input (loop/5800 Series or service/SiX™ Series) ID
codes. Each of the inputs requires a programming zone
(e.g., a 5804E's four inputs require four button zones).
Transmitters can be entered as one of the following types (see transmitter’s instructions for appropriate
Supervision type):
Type
Type
Type
Type
Description
Description
Description
Description
RF Supervised
Sends periodic check-in signals, as well as fault, restore, and low battery signals. The
transmitter must remain within the receiver's range.
RF Unsupervised
Sends all the signals that the Supervised type does, but the Gateway does not supervise
the check-in signals. The transmitter may therefore be carried off-premises.
Button
Sends only fault signals. Does not send low battery signals until activated. The
transmitter is unsupervised and may be carried off-premises.
Transmitter Battery L
Transmitter Battery L
Transmitter Battery L
Transmitter Battery Life
ife
ife
ife
•
Batteries in the wireless transmitters may last from 4–7 years, depending on the environment, usage, and
the specific wireless device being used. Factors such as humidity, high or low temperatures, as well as large
swings in temperature may all reduce the actual battery life in a given installation. The wireless system can
identify a true low battery situation, thus allowing the dealer or user of the system time to arrange a change
of battery and maintain protection for that point within the system.
•
Button-type transmitters should be periodically tested for battery life. The 5804E, 5834-4, 5878 and SiXFOB
button transmitters have replaceable batteries.
Transmitter
Transmitter
Transmitter
Transmitter (Sensor) Firmware Upgrade
(Sensor) Firmware Upgrade
(Sensor) Firmware Upgrade
(Sensor) Firmware Upgrade
The SiX™ Series transmitters (sensors) will receive updated firmware (if required) any time that the Gateway
firmware is updated via AlarmNet 360. The Gateway will attempt to update the sensor firmware every 24 hours
after its firmware has been updated.
Summary of Contents for Lyric LCP300-LC
Page 42: ...Lyric Gateway Installation and Reference Guide 42 Notes Notes Notes Notes ...
Page 43: ...Lyric Gateway Installation and Reference Guide 43 Notes Notes Notes Notes ...
Page 44: ...Lyric Gateway Installation and Reference Guide 44 Notes Notes Notes Notes ...
Page 45: ...Lyric Gateway Installation and Reference Guide 45 Notes Notes Notes Notes ...