background image

 

 

Program the SIXSIREN  

Consult the Controller’s instructions for programming the device in the system. 

 

Fault the device features to “Learn” the device  “Services” in the control:  

-

 

Siren Chime Mode  - Set sound level at the control: 

 

Low  = 35Db

1

 

 

High = 55dB 

 

Life Safety

2

 – select 85dB 

-

 

Cover tamper: The 10 minute tamper timer is reset every time tamper switch 

closed and opened or the siren cover is opened. 

-

 

Temperature sensing – range is 0° – 120° F (-18° – 49° C); accuracy ±3° F (1.67° C)

 

 

 

35dB 

1

 

 

55dB 

 

85dB 

2

 

 

1

Factory default 

Program

 

Mounting 

 

NOTE

: Before mounting the device permanently, 

conduct Go/No Go tests (see controller’s instructions) 

to verify adequate signal strength and adjust the device 

location and orientation as necessary. 

The SIXSIREN can be mounted on the wall or on the 

ceiling. 

The rear tamper breakout MUST be mounted to a stud, 
solid wood, or with a robust wall anchor. 

 

 

 

 

Test the SIXSIREN  

The SIXSIREN should be tested immediately after installation and at least once a year.  Activate Test 

Mode remotely from the Controller (see Controller’s manual for details). 
Test Mode tests the sounder and LED:  

-

 

Sounder – the Burglary warble tone will sound for 3 seconds. 

-

 

LED – the White LED strobe will flash for 15 seconds. 

 

Battery Replacement 

 

Twist the front cover counterclockwise and 

separate it from the mounting bracket.  

 

Remove the batteries, wait 10 seconds and insert 

four new batteries of the same type and brand.  

Recommended replacement batteries:  

-

 

1.5V AA Lithium Batteries [Non-Rechargeable]  

-

 

AA Alkaline batteries can be used, but battery 

life will be significantly reduced. 

NOTE:  Do not mix old and new batteries, 

battery types or manufacturers.  

 

Reattach the front cover and twist clockwise to 

secure it in place.  

BATTERY CAUTION: Risk of fire, explosion and burns.  

Do not recharge, disassemble, heat above 212 F (100 C) or 

incinerate. Dispose of used batteries properly. Keep away 

from children. 

 

Summary of Contents for Lyric SIXSIREN

Page 1: ...troller The controller registers the device and displays the transmitter data on screen 4 Enrollment is confirmed when the Green LED is ON for 3 seconds and the controller chirps once 5 Trigger the device tamper switch again to complete enrollment 6 The device did not enroll in the system if The White LED flashes the system chirps and the device powers down The Green LED flashes rapidly when the d...

Page 2: ...with a robust wall anchor Test the SIXSIREN The SIXSIREN should be tested immediately after installation and at least once a year Activate Test Mode remotely from the Controller see Controller s manual for details Test Mode tests the sounder and LED Sounder the Burglary warble tone will sound for 3 seconds LED the White LED strobe will flash for 15 seconds Battery Replacement Twist the front cover...

Page 3: ... for 3 seconds Burglary Alarm Red flashes once every 45 seconds 2 Low Battery Green Flashes slowly for 10 minutes Tamper Activated 1 Strobe flash two flashes per second then OFF for 1 second 2 It is best to replace the battery BEFORE the chirping begins Once started the sounder continues to chirp until batteries are replaced or die See the Battery Replacement section Specifications Battery Four AA...

Page 4: ...sed for this device must be installed to provide a separation distance of at least 7 8 inches 20 cm from all persons and must not be co located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi transmitter product procedures Mise en Garde Exposition aux Frequences Radio L antenne s utilisée pour cet émetteur doit être installée à une distance de ...

Reviews: