51
Testing Your System
NOTE: TESTING SHOULD BE PERFORMED WEEKLY.
Before testing, the system should be disarmed and all protected doors and windows closed. The
Home button should show green.
No alarm messages are sent to your alarm monitoring company during these tests.
Press Tools and enter the 4-digit Master User code. Press Advanced.
Testing Sensors
(Walk Test)
Home > Security > Tools > Advanced > Walk Test
Start by pressing Walk Test.
The Controller’s internal sounder loudly sounds and Walk Test – Home to Quit appears. The
Controller then beeps every 30 seconds as a reminder that the system is in Test mode.
Note that Walk Test mode automatically quits after 4 hours.
Doors and
Windows
Open each protected door and window in turn and listen for three beeps
from the Controller. If programmed to do so, each zone’s voice descriptor
is heard. Identification of protection points with problems should appear
on the display. Notifications of problem zones clear when the door or
window is closed.
Motion Sensors
Walk in front of each sensor and listen for three beeps and/or voice
descriptors.
The device’s identification should appear on the display when it is
activated. The display clears when no motion is detected.
NOTE: If wireless motion detectors are in use, there is a 3-minute delay
between activations, which helps preserve battery life.
Fire/Carbon
Monoxide sensors
Follow the manufacturer’s instructions to test these devices. When a
device is activated, its identification should appear on the touchscreen.
IMPORTANT
When testing smoke detectors, keep the Lyric™ Controller in test mode for at
least one minute (60 seconds) after testing the detector to avoid sending
unwanted alarm messages to your central station monitoring company.
If there is a problem with any sensor (no confirming sounds, no display), notify your service
company.
When all sensors have been checked (and doors and windows closed), no zone identification
numbers should be displayed.
Finish by pressing Home and entering the Master User code.
Summary of Contents for Lyric
Page 1: ...1 User Reference Guide Ref LCP500 L LCP500 LC 800 18078 11 15 Rev F ...
Page 10: ...10 ...
Page 20: ...20 ...
Page 22: ...22 ...
Page 28: ...28 ...
Page 32: ...32 ...
Page 46: ...46 ...
Page 60: ...60 ...
Page 64: ...64 ...
Page 68: ...68 ...
Page 70: ...70 ...
Page 76: ...76 ...
Page 78: ...78 ZONES Zone Number Location and Description ...
Page 79: ...79 SMART SCENES Smart Scene Name Description Z WAVE DEVICES Type Name Location ...
Page 80: ...80 Notes ...
Page 81: ...81 Notes ...