61
Event Log Codes
The Lyric™ Controller’s Event Log can record and display as many as 6000 system events. Events
are stored locally in the Controller, in chronological order and sent to your monitoring company as
needed. When the maximum number of stored events is reached, the oldest 2000 entries are
deleted to make room for logging new events.
The type of events that can be recorded is selectable; refer to the Lyric Controller Installation and
Reference Guide’s Programming section. The Events and codes displayed vary with your system’s
options. The table below provides definitions of the events/codes that may be transmitted to the
Central Station and/or displayed by the controller.
Note: If the Controller’s backup battery is exhausted after AC power is lost, any system activity
occurring after the Low Battery notification is not saved. Additionally, the Controller appears to have
the same status condition as it did before the low battery notification.
Event Log Codes
Code
Definition
Event Log Display
110
Alarm, Fire
Fire
121
Alarm, Duress
Duress
122
Alarm, Silent
Silent
123
Alarm, Audible
Audible
131
Alarm, Perimeter
Perimeter
132
Alarm, Interior
Interior
134
Alarm, Entry/Exit
Entry/Exit
135
Alarm, Day/Night
Day Night
137
Alarm, Tamper
Tamper
145
Expansion Module Tamper
Expansion Module Tamper
146
Silent Burglary
Silent Burglary
150
24-Hour Non-Burglary
24 Hour Non-Burglary
162
Carbon Monoxide Detected
Carbon Monoxide Detected
301
Trouble, AC Loss
AC Loss
302
Trouble, Low System Battery
Low system battery
305
Trouble, System Reset
System Reset
308
System shutdown
System shutdown
316
System Tamper*
System Tamper
341
Trouble, Case Tamper
Cover Tamper
344
Trouble, RF Receiver Jam Detect
RF Jam Detect
350
Long Range Radio Reset
Long Range Radio Reset
353
Trouble, Long Range Radio Transmitter Fault
Comm. Trouble
354
Failure to Communicate Event
Failure to Communicate Event
373
Trouble, Fire Trouble
Fire trouble
374
Trouble, Exit Error Alarm
Exit error alarm
380
Trouble, Sensor
Sensor trouble
381
Trouble, Loss of Supervision RF
Superv Loss-RF
383
Trouble, Sensor Tamper
Sensor Tamper
Summary of Contents for Lyric
Page 1: ...1 User Reference Guide Ref LCP500 L LCP500 LC 800 18078 11 15 Rev F ...
Page 10: ...10 ...
Page 20: ...20 ...
Page 22: ...22 ...
Page 28: ...28 ...
Page 32: ...32 ...
Page 46: ...46 ...
Page 60: ...60 ...
Page 64: ...64 ...
Page 68: ...68 ...
Page 70: ...70 ...
Page 76: ...76 ...
Page 78: ...78 ZONES Zone Number Location and Description ...
Page 79: ...79 SMART SCENES Smart Scene Name Description Z WAVE DEVICES Type Name Location ...
Page 80: ...80 Notes ...
Page 81: ...81 Notes ...