Rev. B
6-52
HMXMC001013
31-Mar-06
Special Parameters
Pretext Message
Timeout
This field defines the time period in seconds that the pretext message
line text is displayed. Valid values are 2 to 99 seconds.
Enter the desired value and press Enter on the keyboard.
Enable Logging
This determines whether the MAXPRO-Net server stores all the log
messages since the last restart or cold boot. Maximum of 20,000
messages can be stored in the server. Select this check box if you want
to view the events history by connecting MaxMon to the server.
Note: Enabling this option will slow down the server. This is used mainly
for debugging purpose
Ethernet Port
Number
This field defines the port number used by the clients (SetMax or
MaxMon) to connect to the server over the Ethernet. The default port
number will be 26026.
Note: The "Ethernet Port No." will not be live updated to the server.
6.15 DEFINING SERIAL PORTS
The MAXPRO-Net Server uses serial ports to communicate with keyboards, equipment
subracks, and other video equipment. Click on the Serial Ports tab to edit the properties
for each serial communication port. The details of each of the properties are described
below.
Figure 6.13: Serial Ports Tab