Rev. B
6-9
HMXMC001013
31-Mar-06
Video Inputs, Continued
Source
Control
Cont.
Available
Control,
Cont.
VCR, Logging VCR, Standby VCR:
S
.. stop
R
.. record
P
.. play
E
.. tape eject
W
.. rewind/review
F
.. fast-forward/preview
L
.. slow
U
.. pause
Standard Device, Smart Device:
For
DDEV
and
SDEV
control functions the enable flags are
displayed as numbers 1 to 8. This is because these devices can only
be controlled by using the macro method of executing direct control
functions for a device.
Ex: [Q123=^8] Refer to the macro programming manual for further
details.
Control
Locked
The source controls of a PTZ camera site (or VCR etc.) can be locked to prevent user
control of the device. The default lock/unlock status is specified here.
Note:
This locked status can be unlocked by the system operator (if they have the
necessary System Access Level) from the MAXPRO-Net
Menu System (using MaxMon).
Source
Disable
When a video input needs to be temporarily removed from the video input selection
table, the SOURCE DISABLE field would be set to YES. While set, the video input device
CANNOT
be selected by any operator. Under normal operation this field is 'NO'. To
disable a particular video input device, a 'YES' is specified in this field. Enter Y or N in
this field and press Enter on the keyboard.
The SOURCE DISABLE state can be changed (using macro programming) while the
system is in operation e.g. [C123=T] or [C123=F] or through MaxMon.