A P P E N D I X A
VMD Settings and Motion-based Recording Configuration
222
MAXPRO NVR 3.1 Operator’s Guide
A
VMD Configuration Examples
The sensitivity level examples below are provided only for illustration. Other factors such as
lighting level, contrast, and image noise may affect VMD performance and may require further
tuning adjustments as described above.
Normal Field of View
In a normal field of view, with a person walking in front of the camera, the maximum
recommended region-of-interest box sizes would be as shown by the red boxes as in the
following figure.
Figure a-4 Sensitivity Level Comparison: Normal Field of View
Wide Field of View
In a wide field of view camera, the car shown below would be expected to trigger a VMD alarm
if the VMD region-of-interest box is not larger than indicated by the red box.
Figure a-5 Sensitivity Level Comparison: Wide Field of View
Combination Field of View
For cameras with a wide-angle field of view covering a large outdoor scene, people who walk
far away from the camera might appear rather small in the image. If motion needs to be
detected in the entire field of view, the following region-of-interest box configuration is
recommended.
•
Three smaller boxes, set to 30% sensitivity, covering the upper portion of the
image where people appear small.
•
Two larger boxes, set to 50% sensitivity, covering the lower portion of the image
where objects appear larger.
Summary of Contents for MAXPRO
Page 1: ...Document 800 16422V1 Rev E 8 2014 MAXPRO NVR 3 1 Operator s Guide ...
Page 2: ...This page is intentionally left blank ...
Page 4: ...This page is intentionally left blank ...
Page 15: ...Index 249 ...
Page 16: ...This page is Intentionally left blank ...
Page 20: ...This page is Intentionally left blank ...
Page 254: ...I N D E X 254 MAXPRO NVR 3 1 Operator s Guide This page is intentionally left blank ...
Page 255: ......