MBeacon
User’s Guide
6
Marking
The MBeacon is certified according to the IECEx scheme, ATEX and
CSA for US and Canada as protected by intrinsic safety.
The product is marked with the following information:
RAE SYSTEMS
3775 N. 1
st
. St., San Jose
CA 95134, USA
FMC-400
Serial No/barcode: XXX-XXXX-000
IECEx TSA
10.0016X
Ex ia IIC T4
Ex ia I
0575
IM1/II 1G
Ex ia IIC T4
Ex ia I
DNV 10 ATEX 83388X
Class I, Gr. A,B,C,D
T4
Intrinsically Safe
-40º C ≤ Tamb ≤ 50º C
Warnings:
Use only RAE 500-0111-000 for internal battery. Do not replace
internal battery in hazardous locations.
Ui: 3.6V; Ci: 78µF; Li/Ri: 3.5µH/ohm
Understand User’s Manual before operating or servicing.
Substitution of components may impair intrinsic safety.
To prevent ignition of flammable or combustible atmospheres,
disconnect power before servicing.
Applied Standards
IECEx
ATEX
North America
IEC 60079-
0:2004
EN 60079-0:2006 CAN/CSA-C22.2 No. 0-M91
IEC 60079-
11:2006
EN 60079-
11:2007
CAN/CSA-C22.2 No. 157-92
C22.2 No. 142-M1987
UL 913
UL916