background image

OWNER’S MANUAL

Read these instructions before use

Voltage rating:  120V~60Hz
Power rating  :  800W

Portable Air Conditioner

Model: MF08CESWW

Customer Support : 1-800-474-2147

For product inquiries or support : www.honeywellportableac.com

Made in China

MODE

ALARM

8

For service questions, contact Honeywell at 1-800-477-0457.
For sales inquiries, contact Sylvane at 1-800-934-9194 or visit
www.sylvane.com.

Summary of Contents for MF08CESWW

Page 1: ...ortable Air Conditioner Model MF08CESWW Customer Support 1 800 474 2147 For product inquiries or support www honeywellportableac com Made in China MODE ALARM 8 For service questions contact Honeywell at 1 800 477 0457 For sales inquiries contact Sylvane at 1 800 934 9194 or visit www sylvane com ...

Page 2: ...TIONS 17 SERVICE AND WARRANTY 2 1 3 4 5 6 7 8 10 9 11 12 SECTION PAGE 1 INDEX Read all instructions carefully before setting up and operating the unit Keep this instruction manual for future reference This manual is designed to provide important information needed to setup operate maintain and troubleshoot your portable air conditioner Failure to follow these instructions may void the warranty ...

Page 3: ...cooled while a flexible air outlet hose sends heat outside The air conditioner includes a window venting kit No permanent installation is needed The unit is easy to move from room to room and offers a truly flexible air conditioning solution Auto Evaporation System The unit automatically evaporates the condensate through the air outlet hose There is no need to empty the drainage tank except in ver...

Page 4: ...llow installation instructions to set up the unit Plug the unit into a properly grounded circuit To ensure optimal efficiency of the product keep doors and windows closed when it is used as an air conditioner or dehumidifier If the product is being used with the fan function only an open window could improve air circulation 3 USER TIPS MODE ALARM 8 MODE ALARM 8 ...

Page 5: ...facturer or an authorized service agent DO NOT cover the air intake and exhaust when in use This appliance is not intended for use by children Children should be supervised and should not play on or around the appliance DO NOT place objects on or sit on the unit Always turn off and unplug the unit when cleaning or servicing If service is needed contact an authorized service agent Unplug the unit w...

Page 6: ...cord under carpeting and rugs 10 11 Basic safety precautions should always be followed when using electrical appliances Use caution to prevent tripping on cord DO NOT use in areas where gasoline paint or other flammable goods are stored ...

Page 7: ...se Connector 5 Plastic Hose 1 Set 1 Piece 2 Pieces 1 Piece 1 Piece 6 Mode Up Down 1 Control Panel Incl Signal Receptor 2 Air Outlet 3 Handle 4 Casters 5 Air Filter 6 Back Grill 7 Water Drain Cap Air Conditioning Mode 8 Power Supply Cord 9 Exhaust Hose Connector 10 Remote Control 1 2 6 4 3 5 9 10 8 7 MODE ALARM 8 ON OFF Fan Speed Timer ...

Page 8: ...on Connect the plastic hose to the hose connector on back of the unit Note Do not install the window bracket to your window This step is required only to adjust it to the size of your window The bracket should be removed from the window after the size is adjusted Plastic Screw 7 INSTALLATION Push in Rotate For service questions contact Honeywell at 1 800 477 0457 For sales inquiries contact Sylvan...

Page 9: ...et to the opposite end of the plastic hose Ensure that connections are tight and installed properly Connect the window bracket to the window The Portable Air Conditioner is now ready to use 8 INSTALLATION MODE ALARM 8 MODE ALARM 8 ...

Page 10: ... shut off Warning The length of the exhaust hose is designed acording to the product specifications Do not replace or lengthen it with any other pipe or hose as this could cause the unit to malfunction Make sure the back of the unit is at least 20 inches away from a wall Do not place the unit in front of curtains or drapes as this could obstruct the airflow INSTALLATION RECOMMENDED NOT RECOMMENDED...

Page 11: ... will shine orange When fan mode is selected indicator light will shine green Temp and time setting indicator When indicator lights meaning a During operation the unit display present room temperature b When setting temperature the unit will display set temperature Setting range is 61 F 90 F c When setting the time indicator displays set time and indicator flashes d 5 seconds after set temperature...

Page 12: ...g in full cooling mode If room temperature is higher than 25 fan speed can be adjusted otherwise fan speed is fixed to low Note If the unit will be used mainly as dehumidifier do not connect the exhaust hose and let the warm air return in the room Continuous drainage is then necessary and more efficient Fan Mode Air is circulated throughout the room with no cooling Note unit does not need to be ve...

Page 13: ...and poles pointing in the proper direction Caution Use only AAA or IEC R03 1 5V batteries Remove the batteries if the remote control is not in use for a month or longer All batteries should be replaced at the same time do not mix with old batteries Properly dispose of used batteries 12 USE OPERATION ...

Page 14: ...ir filter should be cleaned after every two weeks of use Clean it as follows If the appliance will not be used for a long time be sure to drain the left over water condensation by removing the water drain cap Air Conditioner mode located on the lower backside of the air conditioner Use a shallow pan to collect the water while draining Clean and reinstall air filter 2 To dry excess moisture run the...

Page 15: ...needs to be drained using the following procedures Only in the following conditions should water be drained using the drain plugs on the back of the unit Water Drain Air Conditioning Mode Water Condensation Drainage Water may need to be drained in high humidity areas Unplug the unit from power source remove the drain plug and place a tray under the drain plug See diagram Water will drain out autom...

Page 16: ...es Remove and reconnect the power cord Reset the safety GFI plug if problem persists contact our customer support Drain the water through the drain plug Refer page 14 Water Condensation Draingage The air conditioning unit does not start Problem Possible Cause Solution Runs a short while only Runs but no cooling Lower the set temperature Make sure the exhaust hose is properly connected Connect exha...

Page 17: ...ICATIONS Description of Product Portable Air Conditioner MF08CESWW l e d o M 120 V 60 Hz y c n e u q e r F e g a t l o V 800W Power Consumption 8000 BTU y t i c a p a c g n i l o o C Dehumidifying capacity 50 7 pints 24 hours A 0 1 4 R Refrigerant Type ON OFF r u o h 4 2 r e m i T Dimensions W x D x H inches 19 5 X 14 2 X 24 4 inches 52 lbs 23 6 Kg t h Kg g i e W ...

Page 18: ... are the result of normal wear and tear will not be considered manufacturing defects under this warranty JMA NORTH AMERICA LLC IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY Some jurisdictions do not allow the exclusion or limitati...

Page 19: ...about this product please contact our Customer Support D CUSTOMER SUPPORT JMA North America LLC Ramsey New Jersey 07446 Phone 1 800 474 2147 Email info jmana us When contacting our Customer Support please have the information below along with the proof of purchase All warranty requests must be accompanied by a proof of purchase which is a copy of the original receipt Model Date of purchase Purchas...

Page 20: ...eywell Trademark is used under license from Honeywell International Inc Honeywell International Inc makes no representation or warranties with respect to this product JMA North America LLC Ramsey New Jersey 07446 Customer Support 1 800 474 2147 E mail info jmana us www honeywellportableac com Distributor ...