10
USE & OPERATION
Touch Screen Control Panel
Power Control
Warning Light (when flashing)
Mode Control
Timer Control
Timer / Temperature
Set Controls
Fan Speed Control
After switching the air conditioner off, you must wait 3 minutes before switching it back on again.
Power Control
The Power Control turns the unit on and off.
Mode Control
3 settings: Cool, Dehumidify and Fan
A light will indicate which setting is currently being used.
• Cooling Mode
The unit works as an air conditioner. Adjust fan speed and air
temperature to suit your desired comfort level. Temperature
setting range is 61°F ~ 89°F
• Dehumidifying Mode
Air is dehumidified as it passes through the unit, without being in
full cooling mode. If room temperature is higher than 77°F
fan speed can be adjusted; otherwise fan speed is preset "LOW".
Note : If the unit will be used mainly as a dehumidifier, do not
connect the exhaust hose and let the warm air return in the
room. Continuous drainage is then necessary and more
efficient (refer page 14,
Continuous Draining)
.
• Fan Mode
For air circulation without cooling.
Fan Speed Control
3 settings: High, Medium and Low.
Timer Control
Auto turn off:
With machine in running mode, press timer button to select the
number of hours you want the unit to run in air conditioning mode.
Auto turn on:
With machine in stand by mode, press the timer button to select
the number of hours until you want the unit to automatically start
running.
Temperature / Timer Set Controls
• Used for adjusting the timer and thermostat.
• The default display is room temperature.
• In cooling mode, when “
▼
“ or “
▲
“ button is pressed, the set
temperature is displayed and may be adjusted.
After 10 seconds the display will revert back to room temperature.
Temperature is only adjustable in cool mode.
The time is adjustable between 1~24 hours.
Note : By pressing both “
▼
“ / “
▲
“ set buttons at the same
time, the display will toggle between Celsius and Fahrenheit.
Warning Light
Condensed water may accumulate in the unit. If the internal tank
becomes full, the Power Light will flash and the unit will not
operate until the unit has been drained (refer page 14, Water
Condensation Drainage).