background image

SmartAct N20010, N34010 

 

 

Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37, Switzerland by its Authorized Representative:

 

 

Automation and Control Solutions 

Honeywell GmbH 
Böblinger Straße 17 
D-71101 Schönaich 
Phone: (49) 7031 63701 
Fax:     (49) 7031 637493 
http://europe.hbc.honeywell.com 
 
Subject to change without notice. Printed in Germany 

 

 

Manufacturing location certified to 

 
EN0B-0341GE51 R0307 

DIMENSIONS 

60

30

0

90

shaft

adapter

shaft

adapter (reverse)

anti-rotation bracket

100 mm (3-15/16”)

20.6 mm

(1-3/16”)

48

 mm

(1

-7

/8

”)

95°

223

 mm

 (

8

-2

5/3

2

”)

92 mm (3-5/8”)

10

00 m

m

 (39

”)

5 mm (+0.05, -0.10 mm)

25/128” (+0.002, -0.004”)

2 mm (5/64”)

20 mm (25/32”)

13 mm (1/2”)

7 mm (9/32”)

132 mm (5-3/16”)

min. 60 mm (2-3/8”)

230 mm [+/- 0.5 mm] (9-1/16” [+/-1/64”])

 

Summary of Contents for N20010

Page 1: ... 60 Hz 24 Vdc 10 20 Nominal voltage 24 Vac 50 60 Hz 24 Vdc All values stated hereinafter apply to operation under nominal voltage conditions Power consumption N20010 6 VA 6 W N34010 8 VA 6 W Ambient limits Ambient operating limits 20 60 C 5 140 F Ambient storage limits 40 80 C 40 175 F Relative humidity 5 95 non condensing Safety Protection standard IP54 Protection class II as per EN 60730 1 Overv...

Page 2: ...0 90 0 4 Mechanical end limits 20 Nm 177 lb in models only 5 Declutch button 6 Anti rotation bracket 7 Rotation direction switch 8 Access cover Contents of Package The delivery package includes the actuator itself parts 1 through 8 see Fig 2 the anti rotation bracket screws and the SM mounting plate and screws Modulating Control The actuator is capable of being operated by several controllers prov...

Page 3: ...pping position the autoadapt dip switch for normal operation is set to ON as shown in Fig 4 If it is set to OFF no autoadapting is performed and the control signal map remains constant The autoadapt functionality does not have to be triggered Rather the SmartAct actuator does this automatically when the min and max control signals are provided see Fig 5 the feedback signal is likewise autoadapted ...

Page 4: ...erclockwise position 5 10 15 92 5 0 90 2 5 85 80 75 85 80 75 2 5 90 0 92 5 5 10 15 5 10 15 0 90 85 80 75 CCW internal end switch CW internal end switch actuator scale clockwise end switch scale actuator scale counterclockwise Fig 9 Internal end switches Override If terminal Y of the terminal strip see section Wiring Diagrams on page 6 is unplugged the stroke will be 0 reversing the rotation direct...

Page 5: ...ower Supply In order to comply with protection class II the power source of 24 V actuators must be reliably separated from the network power supply circuits as per DIN VDE 0106 part 101 Access cover To facilitate wiring the actuator to the controller the access cover can be detached from the actuator IMPORTANT Remove power before detaching the access cover Once the access cover has been removed pl...

Page 6: ...ting transformer 24 Vac 24 Vdc END SWITCHES S1 S2 S3 S4 S5 S6 S3 S2 S6 S5 S4 S1 TERMINAL STRIP 1 END SWITCHES NOTE Internal end switches S1 and S4 must be connected to the same power source connecting cable terminal name 1 24 Vac 24 Vdc 2 24 Vac 24 Vdc 3Y 0 2 10 Vdc 0 4 20 mA control signal supply and signal lines must be equipped with spark suppressors 4U 0 2 10 V feedback signal S1 common S2 nor...

Page 7: ...w 2 cable connectors 2 dust protection caps SPARE PARTS Spare Parts Kit Order no A7209 2071 The spare parts kit contains the following items Anti rotation bracket and screws SM Mounting plate and screws Access cover screw Plastic protective cap for protection standard IP54 Mechanical end limit screw and retainer Anti Rotation Bracket Kit Order no A7209 2073 The anti rotation bracket kit can be ord...

Page 8: ...1 Schönaich Phone 49 7031 63701 Fax 49 7031 637493 http europe hbc honeywell com Subject to change without notice Printed in Germany Manufacturing location certified to EN0B 0341GE51 R0307 DIMENSIONS 60 30 0 90 shaft adapter shaft adapter reverse anti rotation bracket 100 mm 3 15 16 20 6 mm 1 3 16 48 mm 1 7 8 95 223 mm 8 25 32 92 mm 3 5 8 1000 mm 39 5 mm 0 05 0 10 mm 25 128 0 002 0 004 2 mm 5 64 2...

Reviews: