Devices
Introduction
1.6.4 Relay Modules
These addressable modules provides the control panel with a dry-contact output for activating a variety of auxiliary devices.
•
FRM-1
Relay Module with two Form-C relays; FlashScan or CLIP mode.
•
XP6-R
Controls six independent Form-C relays; FlashScan or CLIP mode.
1.6.5 Multiple Input/Output Modules
These addressable modules offer dual input and/or dual ouput in a single device.
•
FDM-1
Dual Class B Monitor Module; FlashScan or CLIP mode.
•
FDRM-1
Dual Monitor/Dual Relay Module; functions as two Class B monitor modules and two individual relay modules.
FlashScan or CLIP mode.
1.6.6 Transponders
•
XP Series (XPP-1, XPC-8, XPM-8 & XPR-8)
Provides the FACP with an efficient multiplex subsystem capability. It
communicates with the FACP and functions as a data-gathering panel for alarm Initiating Device Circuits and as a remote switching
center for Notification Appliance Circuits (NAC), telephone circuits or relays. Not FlashScan capable.
For information on connecting these transponders to the SLC, refer to the
XP Transponder Manual
.
1.6.7 Plug-in Detector Bases
Plug-in detector bases provide a connection between the SLC and a variety of intelligent detectors which are snapped into place. Stan-
dard and isolator bases are used depending upon which NFPA SLC style is required. Sounder and relay bases are similar to standard
bases, but have sound or relay capabilities.
•
Standard Base
–
B501
. 4 inch (10.16 cm) standard small diameter base, commonly used in European installations. ) White. For ivory, order
B501-IV
. For black, order
B501-BL.
Note: UL/ULC listed as of January 2018 to replace B501A; compatible for use in Canadian retrofit installations.
–
B300-6
6 inch (15.24 cm) plug-in detector base standard large diameter base, commonly used in US installations.
White. For ivory, order
B300-6-IV.
Replacement model for B210LP.
–
B210LP
6 inch (15.24 cm) standard large diameter base, commonly used in US installations, replacement model for B710LP).
•
HARSH™ Base
- Model
B710HD
used with all HARSH™ detectors
•
Isolator Base
B224BI, B224BI-IV
isolator base.
•
Sounder Base
–
B501BH
Standard sounder base.
–
B501BH-2
UL 864 9th edition compliant standard sounder base.
–
B501BHT-2
UL 864 9th edition compliant temporal sounder base, replaces
B501BHT
.
–
B200S
. Intelligent sounder base.
–
B200SR
Intelligent sounder base, designed to be compatible with existing installations of the B501-Series sounder bases.
–
B200S-LF
A low-frequency version of the B200S
–
B200SR-LF
A low-frequency version of the B200SR.
•
Relay Base B224RB, B224RB-IV
1.6.8 Intelligent Detectors
FCO-851
IntelliQuad PLUS Intelligent Photoelectric Multi-Criteria Smoke/CO (Carbon Monoxide) detector. Plug-in type smoke sensor
that is a photoelectric sensing chamber combined with Carbon Monoxide (CO), thermal, and infra-red (IR) sensors to help reduce false
alarms. For CO, the detectors electromechanical sensing cell creates a separate indication of for life safety CO detection. The FCO-851
adds thermal sensors that will alarm at a fixed temperature of 135° F (57.2° C) and alarm sensitivity options with built-in alarm and pre-
alarm time delay. FlashScan mode only.
FSB-200S
Addressable, intelligent, single-ended beam smoke detector with built-in sensitivity testing. The FSB-200 is the same except
that it does not provide sensitivity testing. Both models support FlashScan and CLIP mode.
FAPT-851
(Acclimate
®
Plus™) Addressable, intelligent detector that combines a photoelectric sensing chamber and fixed temperature
heat detection (135°F / 57.2°C). FlashScan- and CLIP-mode capable. (An earlier version named FAPT-751 was also FlashScan capable.
The model named IPX-751 was discontinued as of December 1, 2001.)
FSC-851
IntelliQuad Intelligent Photoelectric Multi-Criteria Smoke Sensor. Plug-in type smoke sensor that is a photoelectric sensing
chamber combined with Carbon Monoxide (CO), thermal, and infra-red (IR) sensors to help reduce false alarms. The FSC-851 adds
thermal sensors that will alarm at a fixed temperature of 135° F (57.2° C) and alarm sensitivity options with built-in alarm and pre-alarm
time delay. Notifier panels offer different feature sets across different models. Certain features of the FSC-851 may not be available on
some panels. The FSC-851 supports both FlashScan and CLIP modes. Read Status limitations may apply in CLIP mode.
FSI-851
Addressable, intelligent smoke detector that incorporates an ionization sensing chamber. Designed to provide open area protec-
tion. FlashScan- and CLIP-mode capable. (An earlier model named FSI-751 (discontinued) was also FlashScan- and CLIP-mode capa-
ble. Earlier models named CPX-751 and CPX-551 were CLIP mode only.)
FSP-951/FSP-951-IV
Analog, addressable intelligent smoke detector that uses a photoelectric sensing chamber. Listed for use in ducts.
Designed to provide open area protection. The
FSP-951T/FSP-951T-IV
adds thermal sensors that will alarm at a fixed temperature of
135° F (57.2°C). The
FSP-951R/FSP-951R-IV
is a low profile, intelligent photoelectric sensor that is remote test capable, for use with
DNR(W). Basic models support FlashScan mode only; models ending in -IV support FlashScan and CLIP mode. These models update