background image

15

Equipment

8T2 9

ACC Control READER

General Signaling

Equipment

E4662

CE Marking

HID Global hereby declares that these proximity readers are in compliance with the essential requirements 

and other relevant provisions of Directive 2014/53/EU.

Por el presente, HID Global declara que estos lectores de proximidad cumplen con los requisitos esenciales 

y otras disposiciones relevantes de la Directiva 2014/53/EU.

HID Global déclare par la présente que ces lecteurs à proximité sont conformes aux exigences essentielles 

et aux autres stipulations pertinentes de la Directive 2014/53/EU.

A HID Global, por meio deste, declara que estes leitores de proximidade estão em conformidade com as 

exigências essenciais e outras condições da diretiva 2014/53/EU.

HID Global bestätigt hiermit, dass die Leser die wesentlichen Anforderungen und anderen relevanten 

Bestimmungen der Richtlinie 2014/53/EU erfüllen.

HID Global dichiara che i lettori di prossimità sono conformi ai requisiti essenziali e ad altre misure rilevanti 

come previsto dalla Direttiva europea 2014/53/EU.

Download copies of the Radio Equipment Directive Declaration of Conformity (DoC) at: 

http://www.hidglobal.com/certifications

Taiwan

根據NCC低功率電波輻射性電機管理辦法 規定:
第十二條 

 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻
率、加大功率或變更原設計之特性及功能。

第十四條 

 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即
停用,並改善至無干擾時方得繼續使用。 
前項合法通信,指依電信法規定作業之無線電通信。 
低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。

Korean KCC

20, 20K, 40, 40K

항목

규격

송신주파수

RFID:13.56 MHz

수신주파수

RFID:13.56 MHz

출력

RFID: 10m에서 47.544mv이하

전원

DC 12.0V

전파형식

A1D

발진방식

X-tal

변조방식

RFID: ASK, NFC: GFSK

Israel

השימוש במכשיר הינו על בסיס ״משני״ ופטור מרשיון הפעלה אלחוטי

.

רק ״בפעולת בזק״ לשימוש עצמי של הלקוח בלבד

,

 הלקוח פטור מרשיון הפעלה אלחוטי

.

אסור להחליף את האנטנה המקורית של המכשיר

,

 ולא לעשות בו כל שינוי טכני אחר

.

Brazil

Compliance Statement

Este produto está homologado pela ANATEL, de acordo com os procedimentos regulamentados pela 

Resolução 242/2000, e atende aos requisitos técnicos aplicados. Para maiores informações, consulte o 

site da ANATEL - www.anatel.gov.br 

This product is homologated at ANATEL according to procedure regulated by Resolution 242/2000, and 

it complies with the applicable technical requirements. For more information, consult ANATEL website - 

www.anatel.gov.br 

RF Warning Statement

Per Article 6 of Resolution 506, equipment of restricted radiation must carry the following statement in a 

visible location:

Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência 

prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em 

caráter primário. 

This equipment operates in secondary character, meaning it does not have the right of protection against 

harmful interference, even against those the same character, and it cannot cause any interference to 

systems operating in the primary character.

Singapore

Australia and 

New Zealand

Ukraine

Complies with  

IMDA Standards 

DB106440

E4662

South Africa

Signo 20

Signo 20K

TA-2019/2225

APPROVED

TA-2019/2226

APPROVED

Signo 40

Signo 40K

TA-2019/2224

APPROVED

TA-2019/5040

APPROVED

Optional features

Tamper

 – Enabled by default and activated when the mounting plate is removed. The tamper is 

normally closed and changes to open circuit between Tamper 1 and Tamper 2 control lines. Tamper 1 

and Tamper 2 control lines are interchangeable. Either of these lines can be connected with the reader 

ground line to reduce the number of cable cores required in the reader cable. Tamper 1 and Tamper 2 

are rated 0–12VDC at 100mA.

Hold Input

 – When asserted, this line either buffers a card (default) or disables a card read until 

released, as configured.

Specifications

20

20K

40

40K

INPUT VOLTAGE (V DC)

12V DC

CURRENT

STANDBY AVG

1

60 mA

65 mA

65 mA

70 mA

MAX AVG

2

70 mA

75 mA

75 mA

80 mA

PEAK3

250 mA

250 mA

250 mA

250 mA

OPERATING 

TEMPERATURE

-30° F to 150° F (-35° C to 66° C)

CABLE LENGTH

Communication Lines

Wiegand

 = 500 ft - 18 AWG (152 m)

300 ft - 20 AWG (91 m)

RS-485

 = Max bus length: 4,000 ft - 24 AWG (1,219 m)

Max length between nodes: 1,640 ft - 24 AWG (500m)

REGULATORY REF 

NUMBER

20

20K

40

40K

FREQUENCY

BLE: 2.4–2.480 GHz, HF: 13.56 MHz, LF: 125 kHz

FCC IDS

JQ6-SIGNO20

JQ6-SIGNO20K

JQ6-SIGNO40

JQ6-SIGNO40K

IC IDS

2236B-SIGNO20

2236B-SIGNO20K

2236B-SIGNO40

2236B-SIGNO40K

1  Standby AVG - RMS current draw without a card in the RF field.

2  Maximum AVG - RMS current draw during continuous card reads. Not evaluated by UL.

3  Peak - highest instantaneous current draw during RF communication.

Regulatory

UL

Connect only to a Listed Access Control / Burglary power-limited power supply. These readers are intended 

to be used with listed (UL294) control equipment. Suitable for outdoor use.

Only Wiegand, OSDP, and Bluetooth communications have been evaluated by UL.

HID Signo readers are compatible with HID Mobile Access® version 3.0.0 and later using mobile devices with 

BLE version 4.2 and later listed at: 

https://www.hidglobal.com/mobile-access-compatible-devices

.

Install in accordance with NFPA70 (NEC) Local Codes, and authorities having jurisdiction. Follow all National 

and Local Codes.

UL 294 Performance Levels

MODEL #

ACCESS 

CONTROL 

LINE 

SECURITY 

LEVEL

DESTRUCTIVE 

ATTACK 

LEVEL

ENDURANCE 

LEVEL

STAND-BY 

POWER LEVEL CONDITIONS

20 / 20K / 40 / 40K

Level I

Level I

Level IV

Level I

FCC

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and (2) this device must accept any interference 

received, including interference that may cause undesired operation.

CAUTION: Any changes or modifications to this device not explicitly approved by the manufacturer could 

void your authority to operate this equipment.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant 

to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 

interference in a residential installation. This equipment generates, uses and can radiate radio frequency 

energy and, if not installed and used in accordance with the instructions, may cause harmful interference 

to radio communications. However, there is no guarantee that interference will not occur in a particular 

installation. If this equipment does cause harmful interference to radio or television reception, which 

can be determined by turning the equipment off and on, the user is encouraged to try to correct the 

interference by one or more of the following measures:

 

ƒ

Reorient or relocate the receiving antenna.

 

ƒ

Increase the separation between the equipment and receiver.

 

ƒ

Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.

 

ƒ

Consult the dealer or an experienced radio/TV technician for help.

Canada Radio Certification

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the 

following two conditions: (1) this device may not cause interference, and (2) this device must accept any 

interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de 

licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de 

brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le 

brouillage est susceptible d’en compromettre le fonctionnement.

Russia

Дата изготовления указана на маркировке оборудования

Представитель в Российской Федерации

Название

ООО «Дофин»

Адрес

140573, РФ, Московская обл., Озерский район, с. Бояркино

Контактное лицо

Л.Н. Голубова

Телефон

+7 495 223 6008

e-mail

local.declarant@gmail.com

Complies with  

IMDA Standards 

DB106440

E4662

Reviews: